890SD Standalone Drive
Page
5-26
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
RELAY CONTACTS
Name Range
Description
01
DOUT3A
0-24V DC
Relay Output: normally-open, volt-free, 24V DC 1A
resistive load or use down to 1mA, 12V levels
(DOUT3 closed = HEALTH)
02
DOUT3B
0-24V DC
Relay Output: normally-open, volt-free, 24V DC 1A
resistive load or use down to 1mA, 12V levels
(DOUT3 closed = HEALTH)
03
USER 24V 0-24V DC
24V DC Output, 150mA maximum load
X14
04
0V
0-24V DC
0V reference for USER 24V output
Note
The maximum permissible sum of currents from X14/03, X15/08, X15/09 is 150mA. An Alert message
will be displayed if exceeded.
SUPPLY
150mA
X14/03
X15/08
X15/09
X15/01
X15/07
(7mA each)