Operating the Drive
Page
7-44
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
5% Choke
Motor
Power
Input
Voltage
Choke
Inductance
Currents
Drive
Frame
Size
(kW/Hp)
(V)
(
μ
H)
50Hz
1kHz
2.5kHz
Sum
B 4/5 230
CO468342U004
1424 14.85
0.30
2.72
16
C 7.5/10 230
CO468342U011
839 25.20
0.50 4.61 26
D 18.5/25 230 CO468342U018
346 61.20 1.22 11.20 63
E 22/30 230
CO468342U030
294 72.00
1.44
13.18
74
F 45/60 230
CO468342U055
153 138.60
2.77
25.36
141
B 6/10 400
CO468326U006
2918 12.60
0.25
2.31
13
C 15/20 400
CO468326U018
1362 27.00
0.54 4.94 28
D 30/40 400
CO468326U037
693 53.10
1.06 9.72 54
E 45/60 400
CO468326U055
470 78.30
1.57
14.33
80
F 90/150 400
CO468326U110
227 162.00
3.24
29.65
165
G 180/300 400 CO468326U220
114 324.90 6.50 59.46 331
H 280/450 400 CO468326U315
79 468.00 9.36 85.64 476
J 315/500 400 CO468326U355
70 531.00
10.62
97.17 540