Keypad Menus
Page
9-12
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
DIAGNOSTIC MENU
890CD Common Bus Drive & 890SD Standalone Drive
PREF
6511 Display
6901 Display
99.06
BRAKING
Range: FALSE / TRUE
A read-only parameter indicating the state of the dynamic brake switch.
(Refer to the DYNAMIC BRAKING function
block)
73.04
DRIVE FREQUENCY
Range: —.x Hz
The drive output frequency in Hertz.
(Refer to the PATTERN GEN function block)
97.05
ACTIVE TRIPS
Range: 0000 to FFFF
Indicates which trips are currently active. These parameters are a coded representation of the trip status.
(Refer to the TRIPS STATUS function block)
97.06
ACTIVE TRIPS +
Range: 0000 to FFFF
Indicates which trips are currently active. These parameters are a coded representation of the trip status.
(Refer to the TRIPS STATUS function block)
97.09
FIRST TRIP
Range: Enumerated - refer to
block
From when a trip occurs until that trip is reset, this parameter indicates the trip source. When several trips have
occurred, this parameter indicates the first one that was detected.