![Parker 890CS Скачать руководство пользователя страница 417](http://html2.mh-extra.com/html/parker/890cs/890cs_product-manual_3748717417.webp)
Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
Page
D-133
8
9
10
A
B
C
D
E
1
2
3
4
5
6
7
PREF
Name
Block
Type
Range
Default
ro\rw Notes
96.06
TRIP 6
TRIPS HISTORY
ENUM
Same as PREF 96.01
NO TRIP
ro
Output
96.07
TRIP 7
TRIPS HISTORY
ENUM
Same as PREF 96.01
NO TRIP
ro
Output
96.08
TRIP 8
TRIPS HISTORY
ENUM
Same as PREF 96.01
NO TRIP
ro
Output
96.09
TRIP 9
TRIPS HISTORY
ENUM
Same as PREF 96.01
NO TRIP
ro
Output
96.10
TRIP 10 (OLDEST)
TRIPS HISTORY
ENUM
Same as PREF 96.01
NO TRIP
ro
Output
97.01
DISABLE TRIPS
TRIPS STATUS
WORD
0000 to FFFF
0380
rw
97.02
DISABLE TRIPS+
TRIPS STATUS
WORD
0000 to FFFF
0840
rw
97.05
ACTIVE TRIPS
TRIPS STATUS
WORD
0000 to FFFF
0000
ro
Output
97.06
ACTIVE TRIPS+
TRIPS STATUS
WORD
0000 to FFFF
0000
ro
Output
97.07
WARNINGS
TRIPS STATUS
WORD
0000 to FFFF
0000
ro
Output
97.08
W
TRIPS STATUS
WORD
0000 to FFFF
0001
ro
Output
97.09
FIRST TRIP
TRIPS STATUS
ENUM
Same as PREF 96.01
STACK TRIP
ro
Output
98.01
INVERT THERMIST
I/O TRIPS
BOOL
0 : FALSE
1 : TRUE
FALSE rw
98.02
INVERT ENC TRIP
I/O TRIPS
BOOL
0 : FALSE
1 : TRUE
FALSE rw
98.03
INPUT 1 BREAK
I/O TRIPS
BOOL
0 : FALSE
1 : TRUE
FALSE rw
98.04
INPUT 2 BREAK
I/O TRIPS
BOOL
0 : FALSE
1 : TRUE
FALSE rw
98.05
THERMISTOR
I/O TRIPS
BOOL
0 : FALSE
1 : TRUE
FALSE ro
Output
98.06
ENCODER
I/O TRIPS
BOOL
0 : FALSE
1 : TRUE
FALSE ro
Output
98.07
EXTERNAL TRIP
I/O TRIPS
BOOL
0 : FALSE
1 : TRUE
FALSE ro
Output
98.08
EXT TRIP MODE
I/O TRIPS
ENUM
0 : TRIP
1 : COAST
2 : DISABLED
DISABLED rw
98.09
COMMS BREAK
I/O TRIPS
BOOL
0 : FALSE
1 : TRUE
FALSE rw
99.01
ENABLE
DYNAMIC BRAKING
BOOL
0 : FALSE
1 : TRUE
TRUE rw
99.03 BRAKE
RESISTANCE
DYNAMIC
BRAKING
REAL
0.01 to 300.00 Ohm
100.00 Ohm
rw
2
99.04
BRAKE POWER
DYNAMIC BRAKING
REAL
0.1 to 510.0 kW
0.1 kW
rw
2
99.05
1SEC OVER RATING
DYNAMIC BRAKING
REAL
1 to 40
25
rw
2