Programming
Page
D-64
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
A
B
C
D
E
1
2
3
4
5
6
7
PMAC MOTOR
SETUP::MOTOR CONTROL::PMAC MOTOR
Designed for BRUSHLESS SERVO Motor Control Mode.
The
PMAC Motor block is designed to store all the parameters needed to run a PMAC Motor.
Parameter Descriptions
MANUFACTURER
PREF: 134.01
Default: PARVEX
Range:
Enter the motor manufacturer's name.
MODEL
PREF: 134.02
Default: HS620EV
Range:
Enter the motor name.
CONSTRUCTION
PREF: 134.03
Default: 0
Range: See below
Select the motor’s construction type.
Enumerated Value
:
Construction
0 : AXIS
Standard motor.
1 : SPINDLE
Spindle motor.
2 : TORQUE
Direct torque motor.
ATMOSPHERE
PREF: 134.04
Default: 0
Range: See below
Selct the motor’s atmospheric details.
Enumerated Value
:
Atmosphere
0 : STANDARD Standard motor.
1 : EXPLOSIVE Motor built for explosive atmosphere (Ex).