Parameter Descriptions
Enumerated Value
:
SLOT1 FITTED
0 : NONE
No board is present in slot A
1 : FIREWIRE
A Firewire communication board is fitted
2 : PROFIBUS
A Profibus communication board si fitted
3 : CONTROL NET
A Control Net communication board si fitted
4 : CAN
A CAN bus communication board si fitted
5 : UNKNOWN
The board fitted is unknown by the firmware
6 : HTTL INC. ENC.
A HTTL incremental encoder board is fitted
7 : RS485 INC. ENC.
A RS485 incremental encoder board is fitted
8 : ENDAT SIN/COS
An Endat SIN/COS encoder board is fitted
SLOT1 FAULT
PREF: 136.10
Default: 0
Range: See below
This diagnostic defines the slot A error status
Enumerated Value
:
SLOT1 FAULT
0
:
NONE
No
error
1 : PARAMETER VALUE
The board has an error on an internal parameter
2 : TYPE MISMATCH
The defined type doesn’t match the the type of the fitted board
3 : SELFTEST
The board has a selftest error
4 : HARDWARE
There is a hardware error in the board
5 : MISSING
There is no board plugged in but one should be
SLOT1 VERSION
PREF: 136.11
Default: 0000
Range: 0000 to 9999
When a board is plugged in slot A, this diagnostic gives the board version number
SLOT2 FITTED
PREF: 136.12
Default: 0
Range: See below
This diagnostic defines what kind of option board is currently fitted in slot B.