![Parker 890CS Скачать руководство пользователя страница 419](http://html2.mh-extra.com/html/parker/890cs/890cs_product-manual_3748717419.webp)
Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
Page
D-135
8
9
10
A
B
C
D
E
1
2
3
4
5
6
7
PREF
Name
Block
Type
Range
Default
ro\rw Notes
118.10
SYMMETRIC JERK
VIRTUAL MASTER
BOOL
0 : FALSE
1 : TRUE
FALSE rw
118.11
RESET
VIRTUAL MASTER
BOOL
0 : FALSE
1 : TRUE
FALSE rw
118.12
OFFSET
VIRTUAL MASTER
REAL
0.0000 to 360.0000 deg
0.0000 deg
rw
118.13 SPEED
OUTPUT
VIRTUAL
MASTER
REAL _.xx
0.00
Hz
ro Output
118.14
POSITION OUTPUT
VIRTUAL MASTER
REAL
_.xxxx
0.0000 deg
ro
Output
118.15
ACCEL OUTPUT
VIRTUAL MASTER
REAL
_.xx
0.00
ro
Output
118.16
RAMPING
VIRTUAL MASTER
BOOL
0 : FALSE
1 : TRUE
FALSE ro
Output
118.17
CHANNEL
VIRTUAL MASTER
INT
0 to 64
0
rw
118.18
MAX SPEED
VIRTUAL MASTER
REAL
100.0 to 6000.0 RPM
1500.0 RPM
rw
118.19
STATUS
VIRTUAL MASTER
ENUM
0 : READY
1 : RESET
2 : DUPLICATE
3 : INITIALISING
4 : NO FIREWIRE
5 : DISABLED
6 : INTERNAL
DISABLED ro
Output
118.20
SOURCE
VIRTUAL MASTER
ENUM
0 : S RAMP
1 : FEEDBACK ENCODR
2 : REFERNCE ENCODR
SRAMP rw
2
118.22
SPEED FILT TIME
VIRTUAL MASTER
REAL
0.0 to 100.0 ms
5.0 ms
rw
118.23
ACCEL FILT TIME
VIRTUAL MASTER
REAL
0.0 to 100.0 ms
5.0 ms
rw
119.01
CHANNEL
FIREWIRE REF
INT
0 to 62
0
rw
119.02
RESET
FIREWIRE REF
BOOL
0 : FALSE
1 : TRUE
FALSE rw
119.03
INVERT
FIREWIRE REF
BOOL
0 : FALSE
1 : TRUE
FALSE rw
119.04
GEAR RATIO A
FIREWIRE REF
INT
-2000000000 to
2000000000
1000000 rw
119.05
GEAR RATIO B
FIREWIRE REF
INT
-2000000000 to
2000000000
1000000 rw
119.06
POSITION OUTPUT
FIREWIRE REF
REAL
_.xxxx
0.0000 deg
ro
Output
119.07
SPEED OUTPUT
FIREWIRE REF
REAL
_.xx
0.00 Hz
ro
Output
119.08
ACCEL OUTPUT
FIREWIRE REF
REAL
_.xx
0.00
ro
Output