Programming
Page
D-84
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
A
B
C
D
E
1
2
3
4
5
6
7
POS SPEED LOOP OUT
SETUP::MOTION::POS SPEED LOOP OUT
Designed for BRUSHLESS SERVO Motor Control Mode.
This block gives feedbacks from the Position and Speed Loop.
Parameter Descriptions
POS ACTUAL
PREF: 143.01
Default:
Range: -2147483648 to 2147483647
Diagnostic showing drive’s actual position (in units).
SPEED ACTUAL
PREF: 143.02
Default:
Range: -2147483648 to 2147483647
Diagnostic showing drive’s actual speed (in units/s).
POS TH
PREF: 143.03
Default:
Range: -2147483648 to 2147483647
Diagnostic showing drive’s theoretical position (in units).
SPEED TH
PREF: 143.04
Default:
Range: -2147483648 to 2147483647
Diagnostic showing drive’s theoretical speed (in units/s).
ACCEL TH
PREF: 143.05
Default:
Range: -2147483648 to 2147483647
Diagnostic showing drive’s theoretical acceleration (in units/s²)
POS SETPOINT
PREF: 143.06
Default:
Range: -2147483648 to 2147483647
Diagnostic showing drive’s position setpoint (in units).
TRACKING ERROR
PREF: 143.07
Default:
Range: -2147483648 to 2147483647
Diagnostic showing the difference between the position setpoint and the actual position :
Tracking error = pos setpoint – pos actual.