![Parker 890CS Скачать руководство пользователя страница 196](http://html2.mh-extra.com/html/parker/890cs/890cs_product-manual_3748717196.webp)
Keypad Menus
Page
9-10
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
DIAGNOSTIC MENU
890CD Common Bus Drive & 890SD Standalone Drive
PREF
6511 Display
6901 Display
78.21
DIRECT INPUT
Range: —.xx %
The value of the direct input, after scaling and clamping.
(Refer to the SPEED LOOP function block)
78.16
TORQ DMD ISOLATE
Range: FALSE / TRUE
Speed Control mode and Torque Control mode selection. Torque Control mode = TRUE.
(Refer to the SPEED LOOP function block)
83.05
ACTUAL POS LIM
Range: —.xx %
The final actual positive torque limit as a percentage of rated motor torque.
(Refer to the TORQUE LIMIT function block)
83.06
ACTUAL NEG LIM
Range: —.xx %
The final actual negative torque limit as a percentage of rated motor torque.
(Refer to the TORQUE LIMIT function block)
78.07
AUX TORQUE DMD
Range: —.xx %
The auxiliary motor torque as a percentage of rated motor torque as a percentage of rated motor torque.
(Refer to the SPEED LOOP function block)
78.20
TORQUE DEMAND
Range: —.xx %
The demanded motor torque as a percentage of rated motor torque.
(Refer to the SPEED LOOP function block)