![Parker 890CS Скачать руководство пользователя страница 425](http://html2.mh-extra.com/html/parker/890cs/890cs_product-manual_3748717425.webp)
Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
Page
D-141
8
9
10
A
B
C
D
E
1
2
3
4
5
6
7
PREF
Name
Block
Type
Range
Default
ro\rw Notes
135.03
MPS3
PMAC MOTOR 2
REAL
0 to 600 V
480 V
rw
135.04
CURRENT AT MPS1
PMAC MOTOR 2
REAL
0.00 to 1024.00 A
10.60 A
rw
135.05
CURRENT AT MPS2
PMAC MOTOR 2
REAL
0.00 to 1024.00 A
10.60 A
rw
135.06
CURRENT AT MPS3
PMAC MOTOR 2
REAL
0.00 to 1024.00 A
10.60 A
rw
135.07
SPEED AT MPS1
PMAC MOTOR 2
INT
0 to 2147483647
2300
rw
135.08
SPEED AT MPS2
PMAC MOTOR 2
INT
0 to 2147483647
4000
rw
135.09
SPEED AT MPS3
PMAC MOTOR 2
INT
0 to 2147483647
4800
rw
136.01
DRIVE NAME
DRIVE CONFIG
STRING
max length is 14 chars
890 DRIVE
rw
136.02
CONTROL MODE
DRIVE CONFIG
ENUM
0 : VOLTS / Hz
1 : SENSORLESS VEC
2 : CLOSED-LOOP VEC
3 : 4-Q REGEN
4 : PMAC
PMAC ro
Output
136.03
FBK OPT. TYPE
DRIVE CONFIG
ENUM
0 : NONE
1 : ENCODER
2 : RESOLVER
3 : TYPE 3
4 : TYPE 4
5 : TYPE 5
6 : TYPE 6
7 : TYPE 7
RESOLVER rw
136.04
SLOT1 OPT. TYPE
DRIVE CONFIG
ENUM
0 : NONE
1 : RS485
2 : PROFIBUS
3 : LINK
4 : DEVICE NET
5 : CAN OPEN
6 : LONWORKS
7 : CONTROLNET
8 : MODBUS PLUS
9 : ETHERNET
10 : HTTL INC. ENC.
11 : RS485 INC. ENC.
12 : ENDAT SIN/COS
13 : TYPE 13
14 : TYPE 14
15 : TYPE 15
NONE rw