Programming
Page
D-86
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
A
B
C
D
E
1
2
3
4
5
6
7
RESOLVER
SETUP::MOTOR CONTROL::RESOLVER
Designed for BRUSHLESS SERVO Motor Control Mode.
This block defines the parameters used to set up the resolver.
Parameter Descriptions
NAME
PREF: 133.01
Default: PARVEX
Range:
Set the resolver’s name.
POLES
PREF: 133.02
Default: 2
Range: 2 to 20
Set the resolver’s number of poles.
RATIO
PREF: 133.03
Default: 0.5
Range:0.2 to 1.0
Set the resolver’s transformation ratio (at 8kHz, nominal carrier voltage).
SPEED MAX
PREF: 133.04
Default: 10000
Range: 0 to 2147483647
Set the resolver’s maximum mechanical speed in RPM. If unknown, the value must be set to the motor maximum speed.
ACCURACY
PREF: 133.05
Default: 20.00
Range: 0.00 to 60.00 minutes
Set the resolver’s peak to peak accuracy (in minutes). If unknown, use the default value.
CARRIER VOLTAGE
PREF: 133.06
Default: 7.00
Range: 5.00 to 10.00V
Set the resolver’s nominal carrier rms voltage at 8kHz (in Volts). If unknown, use the default value.
CURRENT
PREF: 133.07
Default: 0.046
Range: 0.000 to 1.000A
Set the resolver’s nominal carrier rms current at 8kz under nominal carrier voltage (in Amps). If unknown, use the default value.
INERTIA
PREF: 133.08
Default: 24.00
Range: 10.00 to
32768.00Kg.cm2