COMSPHERE 3600 Series Data Service Units
C-4
July 1999
3610-A2-GB91-90
Table C-4
(2 of 5)
Device Health and Status Messages
Message
Condition
DBMTst:
test,init
The DBM is running a test, initiated from
init.
test is one of the following tests:
BERT
— Bit Error Rate Test
BiL
— Bilateral Loopback
Dev
— Device Test
DL
— Digital Loopback
DT
— Digital Test
DTE
— DTE Loopback
E-E
— End-to-End Test
Lamp
— Lamp Test
LL
— Local Loopback
NetL
— Network Loopback (Switched 56 DBM only)
RL
— Remote Digital Loopback
TM
— Test Mode
init is one of the following initiators:
DTE
— Data Terminal Equipment
FP
— Front Panel (the DCP)
LPDA
— NetView-initiated test
NMS
— Network Management System
Ntwk
— Network (Switched 56 DBM only)
Remt
— Remote DSU
DDS F:
alarm
Digital facility alarm;
alarm is one of the following network alarms:
AbnStatCod — Abnormal Station Code.
BiplrViol
— Excessive Bipolar Violations.
Fac Alarm
— Facility Alarm.
OutofServc — Out-of-Service condition.
No Signal
— No signal has been received.
Dial Tone:Fail
Dial tone test was enabled and test failed.
DSU:Device Fail
Internal failure in the DSU is detected. Go to the Test Branch for Device Test.
DSU:Disable
DSU transmitter is disabled. Go to the Control Branch to enable the DSU.
Содержание COMSPHERE 3610
Страница 4: ...COMSPHERE 3600 Series Data Service Units C July 1999 3610 A2 GB91 90 Notices ...
Страница 16: ...COMSPHERE 3600 Series Data Service Units x July 1999 3610 A2 GB91 90 ...
Страница 27: ...Introduction 1 11 3610 A2 GB91 90 July 1999 Figure 1 4 NMS Interfaces to the SDU 1 of 2 ...
Страница 120: ...COMSPHERE 3600 Series Data Service Units 4 40 July 1999 3610 A2 GB91 90 This page intentionally left blank ...
Страница 128: ...COMSPHERE 3600 Series Data Service Units 5 6 July 1999 3610 A2 GB91 90 ...
Страница 186: ...COMSPHERE 3600 Series Data Service Units 6 58 July 1999 3610 A2 GB91 90 ...
Страница 187: ...A 1 3610 A2 GB91 90 July 1999 Data Service Unit Menu A ...
Страница 188: ...COMSPHERE 3600 Series Data Service Units A 2 July 1999 3610 A2 GB91 90 ...
Страница 189: ...Data Service Unit Menu A 3 3610 A2 GB91 90 July 1999 ...
Страница 190: ...COMSPHERE 3600 Series Data Service Units A 4 July 1999 3610 A2 GB91 90 ...
Страница 192: ...COMSPHERE 3600 Series Data Service Units B 2 July 1999 3610 A2 GB91 90 This page intentionally left blank ...
Страница 224: ...COMSPHERE 3600 Series Data Service Units C 22 July 1999 3610 A2 GB91 90 ...
Страница 246: ...COMSPHERE 3600 Series Data Service Units E 2 July 1999 3610 A2 GB91 90 Figure E 1 Control Channel ...
Страница 247: ...Network Management Connectivity E 3 3610 A2 GB91 90 July 1999 Figure E 2 Extended Control Channel ...
Страница 259: ...Pin Assignments F 11 3610 A2 GB91 90 July 1999 Figure F 8 EIA 232 D Crossover Cable 4951 035F ...
Страница 263: ...Troubleshooting G 3 3610 A2 GB91 90 July 1999 Figure G 2 No Signal NS Condition Troubleshooting ...
Страница 265: ...Troubleshooting G 5 3610 A2 GB91 90 July 1999 Figure G 4 Out of Frame OOF Condition Troubleshooting ...
Страница 272: ...COMSPHERE 3600 Series Data Service Units H 6 July 1999 3610 A2 GB91 90 ...
Страница 278: ...COMSPHERE 3600 Series Data Service Units I 6 July 1999 3610 A2 GB91 90 ...
Страница 280: ...COMSPHERE 3600 Series Data Service Units J 2 July 1999 3610 A2 GB91 90 ...
Страница 292: ...COMSPHERE 3600 Series Data Service Units L 10 July 1999 3610 A2 GB91 90 ...