Configuration Worksheet for MCMP Mode (2 of 3)
Prt6 Options
Value
Async
→
Sync
Enab, Disab
Async Rate
=Sync, 1800, 1200, 600, 300, 150
AsyncBit/Char
6, 7, 8, 9, 10
Stop Bits
1, 2
Overspeed
1.25, 2.5
RTS Cntrl
FrcOn, DTE
TxCarrSel
Const, Cntrl
RxCarrSel
Const, Cntrl, Mark
PCC Buffer
Enab, Disab
Elast Stor
Enab, Disab
RTS/CTS Del
(Chang
)
0–1040 ms
(8 ms increments)
DTR Alarm
Enab, Disab
AntiStream
(Chang
)
Disab, 1–100 sec
(async terminal = 0–100)
DSR FrcOn
Enab, Disab
DSR on Tst
Enab, Disab
Extend Chan
Yes, No
Upstrm Port
Prt1, Prt2, Prt3, Prt4, Prt5, Prt6
DTE Port**
EIA232, V.35
PrtSP (Chanl)
Value
AssgmntPrt1
A, B, C, D, E, F, G, H, None
AssgmntPrt2
A, B, C, D, E, F, G, H, None
AssgmntPrt3
A, B, C, D, E, F, G, H, None
AssgmntPrt4
A, B, C, D, E, F, G, H, None
AssgmntPrt5
A, B, C, D, E, F, G, H, None
AssgmntPrt6
A, B, C, D, E, F, G, H, None
DSU Options
Value
Rate (Kpbs)
56
TxClkSource
Int, RXC, DDS
Msg Clamp
Enab, Disab
TxElasStor
Enab, Disab
RxElastStor
Enab, Disab
19.2 PowrLvl
+6, 0, –10
64KScrambling
On, Off
64KLatchLpbk
On, Off
AggrSwitch
Enab, Disab
AgSw Timing
Int, Aggr
V.54 Lpbk
Enab, Disab
PrtSp Options (DSU)
Value
Prt1
(
)
48, 38.4, 19.2, 18.0
,
16.8, 14.4, 12.0, 9.6, 7.2,
4.8, 2.4, 1.2, Disab
Prt2
(
)
48, 38.4, 19.2, 18.0
,
16.8, 14.4, 12.0, 9.6, 7.2,
4.8, 2.4, 1.2, Disab
Prt3
(
)
48, 38.4, 19.2, 18.0, 16.8, 14.4, 12.0, 9.6, 7.2,
4.8, 2.4, 1.2, Disab
Prt4
(
)
48, 38.4, 19.2, 18.0, 16.8, 14.4, 12.0, 9.6, 7.2,
4.8, 2.4, 1.2, Disab
Prt5
(
)
48, 38.4, 19.2, 18.0, 16.8, 14.4, 12.0, 9.6, 7.2,
4.8, 2.4, 1.2, Disab
Prt6
(
)
48, 38.4, 19.2, 18.0, 16.8, 14.4, 12.0, 9.6, 7.2,
4.8, 2.4, 1.2, Disab
Underspeed:
Disab, Prt1, Prt2, Prt3, Prt4, Prt5, Prt6
PrtSp Optons (DBM)***
Value
Prt1
(
)
56*, 48*, 38.4*, 32*, 28.8*, 19.2*, 18.0*, 16.8*,
14.4, 12.0, 9.6, 8.4
, 7.2, 4.8, 4.0, 2.4, 2.0, 1.2,
Disab
Prt2
(
)
56*, 48*, 38.4*, 32*, 28.8*, 19.2*, 18.0*, 16.8*,
14.4, 12.0, 9.6, 8.4
, 7.2, 4.8, 4.0, 2.4, 2.0, 1.2,
Disab
Prt3
(
)
56*, 48*, 38.4*, 32*, 28.8*, 19.2*, 18.0*, 16.8*,
14.4, 12.0, 9.6, 8.4
, 7.2, 4.8, 4.0, 2.4, 2.0, 1.2,
Disab
Prt4
(
)
56*, 48*, 38.4*, 32*, 28.8*, 19.2*, 18.0*, 16.8*,
14.4, 12.0, 9.6, 8.4
, 7.2, 4.8, 4.0, 2.4, 2.0, 1.2,
Disab
Prt5
(
)
56*, 48*, 38.4*, 32*, 28.8*, 19.2*, 18.0*, 16.8*,
14.4, 12.0, 9.6, 8.4
, 7.2, 4.8, 4.0, 2.4, 2.0, 1.2,
Disab
Prt6
(
)
56*, 48*, 38.4*, 32*, 28.8*, 19.2*, 18.0*, 16.8*,
14.4, 12.0, 9.6, 8.4
, 7.2, 4.8, 4.0, 2.4, 2.0, 1.2,
Disab
Underspeed:
Disab, Prt1, Prt2, Prt3, Prt4, Prt5, Prt6
Diagnostic DSU
Options
Value
Diag Type
NonD, Disr, Mixed, None
2nd Ch(bps)
100, 400, 800, 1200, 1600
Disr Type
2500, 2500, 3600s, 3600e, Br56
* Switched 56 DBM only
** Available for MCMP/Flex with DSU firmware version 6.3
x or greater
*** TDM Backup only
**** 2-wire Switched 56 DBM only
{
Not available if a Switched 56 DBM
{{
Not available if a Primary Core is No
Diagnostic DBM
Options
Value
Diag Type
NonD, Disr, Mixed, None
2nd Ch(bps)
100, 400, 800, 1200, 1600
RemoteDiag
V.54, Enhan, 2500
Diagnostic General
Options
Value
Position
Cntrl, Trib
LinkConfig
Pt-Pt, M-Pt
Resp Period
1, 2, 10
Trib TimOut
(Chang)
sec to
min
Diag Conn
CC, DC
Link Delay
0s, 1s, 2s, 5s, 10s, 20s, 50s
Network Delay
0s, 1s, 2s, 5s, 10s, 20s, 50s
Packet Delay
0s, 1
s,
2s, 5s
Fast Sel
Enab, Disab
DBM Options
Value
Rate(Kbps)
{
14.4, 12.0, 9.6, 4.8, 2.4
TxClkSource
{
Int, RXC, DSU
CarrLossDisc
{
Yes, No
Auto Retrain
{
Yes, No
Single Rate
{
Yes, No
AutoAnswer
Enab, Disab
TxElasStor
Enab, Disab
RxElasStor
Enab, Disab
Call Setup
None, Pswrd, Cllbk, Alarm
RxPwd
(Chang)
TxPwd
(Chang)
V.13 Signl
Enab, Disab
Dial Test
Enab, Disab
Primary Core
Yes, No
DtrCallCon
Orig
{{
, Ansr, Disab
EchoCancel *
Enab, Disab
Remote DBM ***
2-wire, 4-wire
Содержание COMSPHERE 3610
Страница 4: ...COMSPHERE 3600 Series Data Service Units C July 1999 3610 A2 GB91 90 Notices ...
Страница 16: ...COMSPHERE 3600 Series Data Service Units x July 1999 3610 A2 GB91 90 ...
Страница 27: ...Introduction 1 11 3610 A2 GB91 90 July 1999 Figure 1 4 NMS Interfaces to the SDU 1 of 2 ...
Страница 120: ...COMSPHERE 3600 Series Data Service Units 4 40 July 1999 3610 A2 GB91 90 This page intentionally left blank ...
Страница 128: ...COMSPHERE 3600 Series Data Service Units 5 6 July 1999 3610 A2 GB91 90 ...
Страница 186: ...COMSPHERE 3600 Series Data Service Units 6 58 July 1999 3610 A2 GB91 90 ...
Страница 187: ...A 1 3610 A2 GB91 90 July 1999 Data Service Unit Menu A ...
Страница 188: ...COMSPHERE 3600 Series Data Service Units A 2 July 1999 3610 A2 GB91 90 ...
Страница 189: ...Data Service Unit Menu A 3 3610 A2 GB91 90 July 1999 ...
Страница 190: ...COMSPHERE 3600 Series Data Service Units A 4 July 1999 3610 A2 GB91 90 ...
Страница 192: ...COMSPHERE 3600 Series Data Service Units B 2 July 1999 3610 A2 GB91 90 This page intentionally left blank ...
Страница 224: ...COMSPHERE 3600 Series Data Service Units C 22 July 1999 3610 A2 GB91 90 ...
Страница 246: ...COMSPHERE 3600 Series Data Service Units E 2 July 1999 3610 A2 GB91 90 Figure E 1 Control Channel ...
Страница 247: ...Network Management Connectivity E 3 3610 A2 GB91 90 July 1999 Figure E 2 Extended Control Channel ...
Страница 259: ...Pin Assignments F 11 3610 A2 GB91 90 July 1999 Figure F 8 EIA 232 D Crossover Cable 4951 035F ...
Страница 263: ...Troubleshooting G 3 3610 A2 GB91 90 July 1999 Figure G 2 No Signal NS Condition Troubleshooting ...
Страница 265: ...Troubleshooting G 5 3610 A2 GB91 90 July 1999 Figure G 4 Out of Frame OOF Condition Troubleshooting ...
Страница 272: ...COMSPHERE 3600 Series Data Service Units H 6 July 1999 3610 A2 GB91 90 ...
Страница 278: ...COMSPHERE 3600 Series Data Service Units I 6 July 1999 3610 A2 GB91 90 ...
Страница 280: ...COMSPHERE 3600 Series Data Service Units J 2 July 1999 3610 A2 GB91 90 ...
Страница 292: ...COMSPHERE 3600 Series Data Service Units L 10 July 1999 3610 A2 GB91 90 ...