DSU Operations
4-39
3610-A2-GB91-90
July 1999
Messages Branch
The Messages (Msgs) branch of the top-level menu
allows the DSU to receive messages from the NMS and
only displays when a message is waiting. This branch is
available to a DSU configured either as a control or a
tributary, and is selected by pressing the F3 key.
When selected, the message can be read or cleared.
Once cleared, the Msgs selection no longer appears.
Reading a Message
The OK indicator flashes two times per second if a
message is waiting. You can read messages at the local
DSU by selecting Read.
F1
Messages:
Read
Clear
F2
F3
Press the F1 key to select Read.
If the message is less than 16 characters from
beginning to end, the entire message appears. If the
message is greater than 16 characters, use the
or
key to scroll additional lines of the message onto the
display. The direction of the arrow indicates the direction
of the scroll. If less than 16 characters, the entire message
appears.
Clearing a Message
You can clear (delete) messages that are received at the
local DSU by selecting Clear. Press the F2 key to select
Clear.
Press the
key to return to the top-level menu.
Содержание COMSPHERE 3610
Страница 4: ...COMSPHERE 3600 Series Data Service Units C July 1999 3610 A2 GB91 90 Notices ...
Страница 16: ...COMSPHERE 3600 Series Data Service Units x July 1999 3610 A2 GB91 90 ...
Страница 27: ...Introduction 1 11 3610 A2 GB91 90 July 1999 Figure 1 4 NMS Interfaces to the SDU 1 of 2 ...
Страница 120: ...COMSPHERE 3600 Series Data Service Units 4 40 July 1999 3610 A2 GB91 90 This page intentionally left blank ...
Страница 128: ...COMSPHERE 3600 Series Data Service Units 5 6 July 1999 3610 A2 GB91 90 ...
Страница 186: ...COMSPHERE 3600 Series Data Service Units 6 58 July 1999 3610 A2 GB91 90 ...
Страница 187: ...A 1 3610 A2 GB91 90 July 1999 Data Service Unit Menu A ...
Страница 188: ...COMSPHERE 3600 Series Data Service Units A 2 July 1999 3610 A2 GB91 90 ...
Страница 189: ...Data Service Unit Menu A 3 3610 A2 GB91 90 July 1999 ...
Страница 190: ...COMSPHERE 3600 Series Data Service Units A 4 July 1999 3610 A2 GB91 90 ...
Страница 192: ...COMSPHERE 3600 Series Data Service Units B 2 July 1999 3610 A2 GB91 90 This page intentionally left blank ...
Страница 224: ...COMSPHERE 3600 Series Data Service Units C 22 July 1999 3610 A2 GB91 90 ...
Страница 246: ...COMSPHERE 3600 Series Data Service Units E 2 July 1999 3610 A2 GB91 90 Figure E 1 Control Channel ...
Страница 247: ...Network Management Connectivity E 3 3610 A2 GB91 90 July 1999 Figure E 2 Extended Control Channel ...
Страница 259: ...Pin Assignments F 11 3610 A2 GB91 90 July 1999 Figure F 8 EIA 232 D Crossover Cable 4951 035F ...
Страница 263: ...Troubleshooting G 3 3610 A2 GB91 90 July 1999 Figure G 2 No Signal NS Condition Troubleshooting ...
Страница 265: ...Troubleshooting G 5 3610 A2 GB91 90 July 1999 Figure G 4 Out of Frame OOF Condition Troubleshooting ...
Страница 272: ...COMSPHERE 3600 Series Data Service Units H 6 July 1999 3610 A2 GB91 90 ...
Страница 278: ...COMSPHERE 3600 Series Data Service Units I 6 July 1999 3610 A2 GB91 90 ...
Страница 280: ...COMSPHERE 3600 Series Data Service Units J 2 July 1999 3610 A2 GB91 90 ...
Страница 292: ...COMSPHERE 3600 Series Data Service Units L 10 July 1999 3610 A2 GB91 90 ...