Configuration Options
6-45
3610-A2-GB91-90
July 1999
Table 6-12
(2 of 5)
TDM/MCMP Port (MUX Funct: TDM or MCMP) Configuration Options*
Overspeed: 2.5
Next 1.25 2.5 Prev
Overspeed. Selects the overspeed range of the asynchronous-to-synchronous converter. This configuration
option displays only when TDM mode is selected.
1.25
—
Selects the basic overspeed range. Basic range provides 1.25 % overspeed in the DTE
asynchronous data rate.
2.5
—
Selects the overspeed percentage for extended range. Extended range provides 2.5 %
overspeed in the DTE asynchronous data rate.
RTS Cntrl: DTE
Next FrcOn DTE Prev
Request-to-Send Control. Controls the behavior of the internal RTS lead.
FrcOn —
DSU keeps the internal RTS ON continuously. Any data appearing on the transmitted data
(TXD) lead from the DTE is transmitted immediately. Choose this configuration value for
constant-carrier operation. (Refer to configuration option Transmitter Carrier Select that follows
for a description of constant-carrier operation.)
DTE
—
DSU turns ON RTS when the
external RTS is turned ON. CTS is turned ON or Off by the
external control signal RTS. Choose this configuration value for switched-carrier operation.
(Refer to configuration option Transmitter Carrier Select that follows for a description of
switched-carrier operation.)
TxCarrSel: Const
Next Const Cntrl Prev
Transmitter Carrier Select.
1
Enables the TDM or MCMP transmitter circuitry to simulate switched-carrier
operation (using the V.13 codes) on an individual channel. The simulated switched-carrier operation is also
referred to as pseudo-controlled carrier (PCC) mode. It is required for applications where the receiving DTE
expects a raised LSD lead prior to receiving data.
Const
—
Transmit Constant Carrier (constant-carrier operation). The V.13 codes are not sent. The
corresponding remote TDM or MCMP port must be configured for Receiver Constant Carrier or
Mark (RxCarrSel set to Const or Mark). Configure each port in a digital-sharing group for
Constant Carrier operation (TxCarrSel set to Const).
Cntrl
—
Transmit Controlled Carrier (switched-carrier operation, PCC mode). The DSU transmits the
V.13 codes over the DDS line when the port RTS changes state. When RTS is turned ON, the
DSU transmits a code that turns ON LSD at the remote TDM or MCMP port before CTS is
turned ON at the local TDM or MCMP port. When RTS is dropped, the DSU sends a code that
turns Off LSD at the remote TDM or MCMP port. The corresponding remote TDM or MCMP
port must be configured for Receiver Controlled Carrier (RxCarrSel set to Cntrl). This selection
is not valid if the DSU is part of a Digital-Sharing Device (DSD) group. (See the Mark selection
in the configuration option Receiver Carrier Select.)
NOTE: A port may be configured for switched-carrier operation in one direction and constant-carrier
operation in the other direction.
1
For MCMP mode, this configuration option is ignored
except during dial backup when the MCMP Bckup
configuration option is set to TDM or a V.32 DBM is installed.
* The menu paths for Port 1 through Port 6 are identical.
Содержание COMSPHERE 3610
Страница 4: ...COMSPHERE 3600 Series Data Service Units C July 1999 3610 A2 GB91 90 Notices ...
Страница 16: ...COMSPHERE 3600 Series Data Service Units x July 1999 3610 A2 GB91 90 ...
Страница 27: ...Introduction 1 11 3610 A2 GB91 90 July 1999 Figure 1 4 NMS Interfaces to the SDU 1 of 2 ...
Страница 120: ...COMSPHERE 3600 Series Data Service Units 4 40 July 1999 3610 A2 GB91 90 This page intentionally left blank ...
Страница 128: ...COMSPHERE 3600 Series Data Service Units 5 6 July 1999 3610 A2 GB91 90 ...
Страница 186: ...COMSPHERE 3600 Series Data Service Units 6 58 July 1999 3610 A2 GB91 90 ...
Страница 187: ...A 1 3610 A2 GB91 90 July 1999 Data Service Unit Menu A ...
Страница 188: ...COMSPHERE 3600 Series Data Service Units A 2 July 1999 3610 A2 GB91 90 ...
Страница 189: ...Data Service Unit Menu A 3 3610 A2 GB91 90 July 1999 ...
Страница 190: ...COMSPHERE 3600 Series Data Service Units A 4 July 1999 3610 A2 GB91 90 ...
Страница 192: ...COMSPHERE 3600 Series Data Service Units B 2 July 1999 3610 A2 GB91 90 This page intentionally left blank ...
Страница 224: ...COMSPHERE 3600 Series Data Service Units C 22 July 1999 3610 A2 GB91 90 ...
Страница 246: ...COMSPHERE 3600 Series Data Service Units E 2 July 1999 3610 A2 GB91 90 Figure E 1 Control Channel ...
Страница 247: ...Network Management Connectivity E 3 3610 A2 GB91 90 July 1999 Figure E 2 Extended Control Channel ...
Страница 259: ...Pin Assignments F 11 3610 A2 GB91 90 July 1999 Figure F 8 EIA 232 D Crossover Cable 4951 035F ...
Страница 263: ...Troubleshooting G 3 3610 A2 GB91 90 July 1999 Figure G 2 No Signal NS Condition Troubleshooting ...
Страница 265: ...Troubleshooting G 5 3610 A2 GB91 90 July 1999 Figure G 4 Out of Frame OOF Condition Troubleshooting ...
Страница 272: ...COMSPHERE 3600 Series Data Service Units H 6 July 1999 3610 A2 GB91 90 ...
Страница 278: ...COMSPHERE 3600 Series Data Service Units I 6 July 1999 3610 A2 GB91 90 ...
Страница 280: ...COMSPHERE 3600 Series Data Service Units J 2 July 1999 3610 A2 GB91 90 ...
Страница 292: ...COMSPHERE 3600 Series Data Service Units L 10 July 1999 3610 A2 GB91 90 ...