45
Installation Manual
Battery Connection & Charging Information
Step 1. If not completed already from earlier, connect the other end of the
battery connection cable to the large terminal block located in the battery
enclosure. See image below.
Step 2. Check that every battery has a red wire to the battery positive
binding posts and to the positive terminal block. Check that every battery
has a black wire to the battery negative binding posts and to the negative
terminal block. Note, The larger/longer wires go to the top batteries. The
smaller/shorter wires go to the middle and bottom batteries.
CAUTION:
Before making the final connection or closing the
breaker, make sure the connections have the correct polarity.
Check polarity labels above.
CAUTION:
Do NOT apply anti-oxidant substance on the
terminals before terminals are connected tightly.
CAUTION:
Do not place anything between the flat part of
the inverter terminal and the ring terminal. Otherwise,
overheating may occur.
WARNING:
Check positive (+) and the negative (-) terminals.
If EverVolt is connected with reversed polarity, unexpected
reactions may occur such as damages, heat generation,
smoke, fire, or explosion.
WARNING:
Do not connect between the positive (+) and
negative (-) terminals with a conductive material (e.g. wire,
a cable, etc.). This may result in damages, heat generation,
smoke, fire, or explosion.
Содержание EverVolt EVAC-105-6
Страница 1: ...V 01012021 Installation Service Manual FOR AC AND DC COUPLED EVERVOLT SYSTEMS ...
Страница 65: ...65 Installation Manual Operation and Display Panel ...
Страница 76: ...76 Installation Manual Configuring the Hardware PV INPUT IS ONLY USED FOR EVERVOLT DC COUPLED SYSTEM ...
Страница 83: ...83 Installation Manual Step 5 Install the Generator wire ...