51
Installation Manual
Installing the SmartHub
CONNECTING TO THE INVERTER
Step 1.
Insert the black wire of the RS485
cable into the first pin, (T0) D-, and
the red wire into the second pin,
(T0) D+, of the SmartHub. Then
use a small flathead screwdriver
to tighten the screws.
Step 2.
Open the door on the inverter and remove the dead front cover if needed
(See inverter manual for instructions). Look inside and on the top bulkhead
panel you should find a green socket (with 4 pins) labeled “RS485 S”.
Step 3.
Connect the RS485 connector
into the first two pins of the port
labeled “RS485 S” on the inverter.
Push the connector in hard so that
it seats properly.
RS485 S
RS485 M