93
Installation Manual
DC BATTERY CHARGER
Maximum Charge Current
60A
Output Voltage Range
43 to 58V (48V Nominal)
Compatible Battery Types
Li-ion
Battery Bank Range
10 to 33 kWh
GENERAL SPECIFICATIONS
Product weight
335 to 1000 lbs
Product dimensions (H x W x D)
24.2" x 42.5" x 10" (Per enclosure)
IP degree of protection
NEMA Type 1/IP20
Temperature
Operating: -20 to 55°C (0°C Min Startup Temp. &
power derated above 40°C )
Storage: -25 to 70°C (-13 to 158°F)
Compliances
STANDARD COMPLIANCE
Safety UL9540, UL1973, UL1741SA, CSA 22.2
Grid Connection Standards IEEE 1547A, IEEE 1547.1
Emissions FCC part15 class B
Standards Rule 21, HECO
Specifications
AC OUTPUT TO LOAD
WITH GRID ABSENT
WITH GRID PRESENT
Output Power (Continuous)
@ 25°C
5500W
7000W
Overload 40/20/5/1sec @
25°C & 240V
5500/--/6500/7500W
--/9600/--/--W
Overload 40/5/1sec @
25°C & 120V
2750/3250/3750W
--
Rated Output Current (RMS)
23A (120V and 240V)
29A (@120V and 240V)
Output Frequency (Selectable)
50/60Hz
Output Voltage and Accuracy
L-N: 120V ± 3%; L-L: 240V ± 3%
Output Voltage Limits
L-L: 180 to 280V (240V Nominal)
Total harmonic distortion
(THD) at rated power
< 5%
Power Factor
>99%
AC-Coupled System
Содержание EverVolt EVAC-105-6
Страница 1: ...V 01012021 Installation Service Manual FOR AC AND DC COUPLED EVERVOLT SYSTEMS ...
Страница 65: ...65 Installation Manual Operation and Display Panel ...
Страница 76: ...76 Installation Manual Configuring the Hardware PV INPUT IS ONLY USED FOR EVERVOLT DC COUPLED SYSTEM ...
Страница 83: ...83 Installation Manual Step 5 Install the Generator wire ...