Setting Sensing
ZW User's Manual
77
4
Settings for
Func
tion
Automatically Following the Range of Measurement Area2
When 2 area mode is set, the measurement area 2 can be set automatically to measure the measurement
surface (Follow) , and the measurement area 2 range can be follow the measurement surface (Base)
movement.
This function is used when a few surface of vibrating object is measured stabile.
Explorer pane
: [Bank] | [(Bank Data Name)] (double click)
Edit pane
: [Sensing setting] icon (
)
Sensing settings window : [Measurement area 2] - [Area follow setting]
Item
Setting item
Setting value
Description
Area follow
settings
Area follow
OFF (default
value)
Area follow is not set. Select this to set any desired value.
Upper line
Adjust the measurement area of measurement area 2 to track the [Start]
setting value for measurement area 1.
Lower line
Adjust the measurement area of measurement area 2 to track the [End]
setting value of measurement area 1.
Upper line and
lower line
Adjust the measurement area of measurement area 2 to track the [Start] and
[End] setting value of measurement area 1.
Base
Edge1/Edge2/
Edge3/Edge4/
peak
(default value:
Edge1)
Select the measurement surface of measurement area 1 to be used as the
reference for automatic tracking.
The peak is the surface of all measurement surfaces having the highest
received light amount.
Follow
Edge1/Edge2/
Edge3/Edge4/
peak
(default value:
Edge2)
Select the measurement surface of measurement area 1 to be used as the
reference for automatic tracking.
The measurement area 2 is automatically set referenced to the surface
selected when [Area Teach] is clicked.
The peak is the surface of all measurement surfaces having the highest
received light amount.
Base
Follow
Area2 upper line
Area2 lower line
Содержание ZW-C1*T
Страница 17: ...1 Basic configuration Basic configuration 1 1 ZW series Displacement Sensors 16 1 2 Basic Operation Flow 17 ...
Страница 70: ...Operating with Sensor Controller 68 ZW User s Manual MEMO ...
Страница 116: ...Setting the System 114 ZW User s Manual MEMO ...
Страница 134: ...Controll input signal with PC tool 132 ZW User s Manual MEMO ...
Страница 209: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 208 8 2 Troubleshooting 210 ...
Страница 319: ...Index ZW User s Manual 317 Index 11 ...
Страница 321: ......