Setting Sensing
230
ZW User's Manual
Setting Exposure Time Control Mode
Setting Exposure Time Control Mode p.75
As an example, here is an explanation of the procedure for setting the exposure time control mode to "AUTO"
and the exposure time (maximum) to "500
s".
Operating procedure
Steps
Key operation
Display
Description
1
Press and hold the
key for two seconds to enter the FUN
mode.
2
Press the
/
keys to select "SENS" and press the
key.
3
Press the
/
keys to select "EXPOSE" and press the
key.
4
Select the exposure time control mode.
AUTO: Automatic
MANUAL: Fixed
The current setting value is displayed on the sub-display.
Press
/
key to enter editing mode and the sub-display blinks.
In this example, select "AUTO" and press the
key.
5
Set the exposure time (maximum) or exposure time (fixed).
In this example, "UPPER" is displayed on the main display, and the
current setting value is displayed on the sub-display.
Press
key to enter the editing mode, and the sub-display
blinks.
To edit numerical values, use the
/
/
/
keys.
In this example, select "500" and press the
key.
6
Press the
key for two seconds to enter the RUN mode.
Содержание ZW-C1*T
Страница 17: ...1 Basic configuration Basic configuration 1 1 ZW series Displacement Sensors 16 1 2 Basic Operation Flow 17 ...
Страница 70: ...Operating with Sensor Controller 68 ZW User s Manual MEMO ...
Страница 116: ...Setting the System 114 ZW User s Manual MEMO ...
Страница 134: ...Controll input signal with PC tool 132 ZW User s Manual MEMO ...
Страница 209: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 208 8 2 Troubleshooting 210 ...
Страница 319: ...Index ZW User s Manual 317 Index 11 ...
Страница 321: ......