
Connecting Parallel I/O
274
ZW User's Manual
Setting the Clamp Value
Setting the Clamp Value for Analog Output p.151
As an example, the following explains the procedure for setting the clamp value to "analog voltage output 10V".
Operating procedure
Steps
Key operation
Display
Description
1 to 4
For moving to "HLD.RST" - "CLAMP", see steps 1 to 4 in p.273.
2
Press the
/
keys to select "ANALOG" and press the
key.
6
Set the clamp value.
The current setting value is displayed on the sub-display.
Press
/
key to enter editing mode and the sub-display blinks.
Select "10V" and press the
key.
7
Press the
key for two seconds to enter the RUN mode.
Содержание ZW-C1*T
Страница 17: ...1 Basic configuration Basic configuration 1 1 ZW series Displacement Sensors 16 1 2 Basic Operation Flow 17 ...
Страница 70: ...Operating with Sensor Controller 68 ZW User s Manual MEMO ...
Страница 116: ...Setting the System 114 ZW User s Manual MEMO ...
Страница 134: ...Controll input signal with PC tool 132 ZW User s Manual MEMO ...
Страница 209: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 208 8 2 Troubleshooting 210 ...
Страница 319: ...Index ZW User s Manual 317 Index 11 ...
Страница 321: ......