Parallel I/O connection
152
ZW User's Manual
Setting the Clamp Value for Binary Output
Set the clamp value to output when "Clamp" is selected as processing when measurement is not possible.
Explorer pane
: [Bank] | [(Bank Data Name)] (double click)
Edit pane
: [I/O Settings] icon (
)
I/O Setting Screen
: [Binary output]
Clamp values can also be set with key operations on the Sensor Controller.
Item
Setting item
Setting value
Description
Binary output
Clamp output
MIN (Default value)/MAX
Select the binary output at clamp output.
MIN: -1048576
MAX: 1048575
1
Set the operating mode to the FUN mode.
3-3 Switching operation modes p.57
2
Select the output value at [Clamp output].
Clamp values can also be set with key operations on the Sensor Controller.
Note
Note