
Setting the Output Conditions
ZW User's Manual
239
Senso
r con
trol
ler ope
ra
ti
ons
9
Setting the Differentiation Filter
Setting the Differentiation Filter p.93
As an example, here is an explanation of the procedure for selecting the "10ms" number of differential cycles.
Operating procedure
Steps
Key operation
Display
Description
1 to 4
For moving to "FILTER", see steps 1 to 4 in p.236.
5
Select "DIFFER" as the filter type.
Press the
/
keys to select "DIFFER" and press the
key.
6
Enable the differentiation filter.
The current setting value is displayed on the sub-display.
Press
/
key to enter editing mode and the sub-display blinks.
Select "ON", then press the
key.
7
Set the number of differential cycles.
"CYCLE" is displayed on the main display and the current setting
value is displayed on the sub-display.
Press
key to enter the editing mode, and the sub-display
blinks.
To edit numerical values, use the
/
/
/
keys.
In this example, input "10", then press the
key.
8
Press the
key for two seconds to enter the RUN mode.
Содержание ZW-C1*T
Страница 17: ...1 Basic configuration Basic configuration 1 1 ZW series Displacement Sensors 16 1 2 Basic Operation Flow 17 ...
Страница 70: ...Operating with Sensor Controller 68 ZW User s Manual MEMO ...
Страница 116: ...Setting the System 114 ZW User s Manual MEMO ...
Страница 134: ...Controll input signal with PC tool 132 ZW User s Manual MEMO ...
Страница 209: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 208 8 2 Troubleshooting 210 ...
Страница 319: ...Index ZW User s Manual 317 Index 11 ...
Страница 321: ......