Parallel I/O connection
ZW User's Manual
137
6
Commun
ication
s with Exte
rnal De
vi
ces
Bank selection input
LOGGING input
Name
Description
BANK_SEL input
This is used for switching banks.
Specify the bank number in combinations of BANK_SEL1, 2 and 3.
However, if the bank mode is set to "JUDGEMENT", the bank cannot be switched at the external
signal input because the number of banks increases to 32.
Bank Number
BANK_SEL1
BANK_SEL2
BANK_SEL3
BANK1
OFF
OFF
OFF
BANK2
ON
OFF
OFF
BANK3
OFF
ON
OFF
BANK4
ON
ON
OFF
BANK5
OFF
OFF
ON
BANK6
ON
OFF
ON
BANK7
OFF
ON
ON
BANK8
ON
ON
ON
Name
Description
LOGGING input
This is used to start internal logging.