Wiring
44
ZW User's Manual
Class
Name
Description
Parallel
output
BANK_OUT output
This outputs the currently specified bank number.
It expresses the bank number in combinations of BANK_OUT1, 2 and 3.
BINARY output
This outputs the measurement result or judgment value as binary.
The measured value is output converted to 21 bits of binary data.
All the task judgment results can be output together.
BINARY_OUT output
This outputs the task number currently output as binary.
It expresses the task number in combinations of BINARY_OUT1 and 2.
GATE output
This is the timing signal for taking in binary data with external devices.
When the GATE signal is ON, take in the binary data.
Bank Number BANK_OUT1
BANK_OUT2
BANK_OUT3
BANK1
OFF
OFF
OFF
BANK2
ON
OFF
OFF
BANK3
OFF
ON
OFF
BANK4
ON
ON
OFF
BANK5
OFF
OFF
ON
BANK6
ON
OFF
ON
BANK7
OFF
ON
ON
BANK8
ON
ON
ON
Task Number BINARY_OUT1
BINARY_OUT2
TASK1
OFF
OFF
TASK2
ON
OFF
TASK3
OFF
ON
TASK4
ON
ON
Содержание ZW-C1*T
Страница 17: ...1 Basic configuration Basic configuration 1 1 ZW series Displacement Sensors 16 1 2 Basic Operation Flow 17 ...
Страница 70: ...Operating with Sensor Controller 68 ZW User s Manual MEMO ...
Страница 116: ...Setting the System 114 ZW User s Manual MEMO ...
Страница 134: ...Controll input signal with PC tool 132 ZW User s Manual MEMO ...
Страница 209: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 208 8 2 Troubleshooting 210 ...
Страница 319: ...Index ZW User s Manual 317 Index 11 ...
Страница 321: ......