Setting the Output Conditions
98
ZW User's Manual
Explorer pane
: [Bank] | [(Bank Data Name)] (double click)
Edit pane
: [Task Settings] icon (
)
Task Settings window : [Hold]
Set "Trigger hysteresis" according to the fluctuation of the measured value near the trigger level. Hysteresis is applied
simultaneously with start of measurement to prevent chattering of the TIMING input.
1
Set the hold mode.
2
Select the trigger method from [Trigger
settings] - [Trigger method].
3
Enter [Trigger level] and [Trigger hysteresis]
when [Selfup trigger] or [Selfdown trigger]
are selected at [Trigger method].
The trigger can also be set by the operating keys on the Sensor Controller.
Important
Note