Wiring
42
ZW User's Manual
Connecting Sensor Controller power supply
hen connecting the power supply, be sure to adhere to the following requirements:
• For the power supply, use AWG18 to 28 cables.
• Make the cable tip exposed by approx. 7 mm.
2
Push in and hold the release button next to the termi-
nal hole using a screwdriver while pushing the wire
fully into the terminal hole and remove the screwdriv-
er.
After the connection has been established, pull the wire
gently, to make sure that the connection has been made
securely.
3
Reinstall the 20-pole terminal block to the Sensor
Controller.
1
Connects 24 VDC power supply to terminals 9 and 10
on the 20-pole terminal block.
The following product is recommended for the 24 VDC power supply:
S8VS-06024 (Omron, 2.5 A, 60 W)
Release button
Terminal hole
DIN track
attachment
hook
Important
Note