No-protocol Connection
ZW User's Manual
175
6
Commun
ication
s with Exte
rnal De
vi
ces
• When the output timing is such that multiple records are buffered, data for up to 10 records is output together.
• When output data is buffered faster than it is output, the outputting can not keep up and an overflow occurs in the
ZW. If this happens, "OUT.OVR" appears on the main segment. You can recover from the error display by pressing
the ESC/ZERORST key.
• Up to 128 records of output can be buffered.
• Data output destination can also be set by the operating keys on the Sensor Controller.
Setting Serial Data Output p.279