Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
10-19
Camera and IP Setup
Focus Setup
Focal Distance
Distance Units
Focus Mode
Definition:
Provides the focal distance adjustment for the camera.
Any value outside this range will be rejected.
If you attempt to set the Focal distance as the out of range value of your
model, the parameter will be left as-is.
Serial Cmd:
<
K525,
focal distance
,distance units,focus mode,no-read limit
>
Default:
102
Options:
25 to 4,000 (mm)
100 to 4,000 (1/100 inch)
Definition:
Defines the measurement unit value of the
Focal Distance
parameter.
Serial Cmd:
<
K525,
focal distance,
distance units
,focus mode,no-read limit
>
Default:
Millimeters
Options:
0 = Millimeters
1 = 1/100 inch
For example, the following are valid configurations to set the Focal Distance to three distances:
Required Focal Distance
Distance Units = mm (0)
Distance Units = 1/100 in. (1)
2 inch, or 50 mm
<K525,50,0>
<K525,200,1>
3 inch, or 76 mm
<K525,76,0>
<K525,300,1>
6 inch, or 152 mm
<K525,152,0>
<K525,600,1>
Definition:
This field set to
1
enables the autofocus mode to be enabled. The read
cycle must also be a
Continuous Read
mode or
Continuous Read
Auto
(Auto Photometry) mode. Autofocus mode does not apply to triggered
read cycles. If the value is set to
0
, only the distance value is used.
Serial Cmd:
<
K525,
focal distance,distance units,
focus mode
,no-read limit
>
Default:
No-Read Autofocus
Options:
0 = User Value Only
1 = No-Read Autofocus
Содержание V430-F-series
Страница 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Страница 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Страница 97: ...4 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 Additional Notes about Calibration ...
Страница 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Страница 265: ...8 30 Auto Focus Multi Code Reader V430 series User s Manual Z392 ISO IEC 29158 Symbol Quality Output ...
Страница 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Страница 325: ...11 18 Auto Focus Multi Code Reader V430 series User s Manual Z392 Request All Configuration Database Settings ...
Страница 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...