5-24
Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
Image Processing Timeout
Image Processing Timeout
Notes:
• The timeout period does not include capture time.
• If a timeout occurs during processing and no symbols in the field of view have been
decoded, the image will be recorded as a No-Read. For this reason, a longer timeout
should be tried to ensure that the symbol is decoded successfully.
Usage:
Useful in higher speed applications where image processing time is long
enough that not all captures have an opportunity to be processed.
Definition:
Specifies the maximum amount of time to process a captured image.
When the timeout expires, the image processing is aborted. This timeout
works in both
Rapid Capture
and
Continuous Capture
modes, as well
as with the Configuration Database.
Serial Cmd:
<
K245,
image processing timeout
>
Default:
5000 ms
(5 sec.)
Options:
1 to 65535 (in 1 ms increments)
Содержание V430-F-series
Страница 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Страница 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Страница 97: ...4 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 Additional Notes about Calibration ...
Страница 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Страница 265: ...8 30 Auto Focus Multi Code Reader V430 series User s Manual Z392 ISO IEC 29158 Symbol Quality Output ...
Страница 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Страница 325: ...11 18 Auto Focus Multi Code Reader V430 series User s Manual Z392 Request All Configuration Database Settings ...
Страница 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...