7-12
Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
Output Indicators
Static Presentation Mode
Static Presentation Mode
is used in conjunction with
Continuous Read Mode
:
<K200,0>
.
When operating in
Static Presentation Mode
, the red LEDs will illuminate while the
reader is searching for a symbol in
Continuous Read Mode
. When a symbol is placed in
the field of view and a good read occurs, the green LEDs will illuminate and stay on for the
duration of time set in
Green Flash Duration
. Only one read will occur during that time
unless more than one symbol is enabled in
Number of Symbols
.
Note:
If
Static Presentation Mode
is selected but the reader is not in
Continuous Read
,
the
Green Flash
will not occur.
To use Static Presentation:
1. Enable
Continuous Read
.
2. Select the number of symbols.
3. Enable
Static Presentation
in
Green Flash Mode
.
4. Select the read time in
Green Flash Duration
.
Match
The green LEDs will flash when a match condition is met. If multisymbol is enabled, then
green flash LEDs will illuminate only if all symbols qualify as a match. If matchcode is
disabled, then this mode will activate the LEDs on a good read.
Mismatch
Same as
Match
, except that LEDs will illuminate on a mismatch.
Strobe
Green flash LEDs will act as an illumination strobe for image capture. If it is required that the
green flash LEDs be the
only
illumination for image capture, then the internal illumination
LEDs can be disabled.
Содержание V430-F-series
Страница 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Страница 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Страница 97: ...4 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 Additional Notes about Calibration ...
Страница 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Страница 265: ...8 30 Auto Focus Multi Code Reader V430 series User s Manual Z392 ISO IEC 29158 Symbol Quality Output ...
Страница 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Страница 325: ...11 18 Auto Focus Multi Code Reader V430 series User s Manual Z392 Request All Configuration Database Settings ...
Страница 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...