Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
3-15
Communications
Protocol Configuration Examples
Point-to-Point (Main Port)
Polling Mode (Main Port)
“User-Defined” Polling Mode (Main Port)
ACK/NAK (Main Port)
<K100,8,0,1,1>
Baud Rate:
115.2K
; Parity:
None
; Stop Bits:
2
; Data Bits:
8
<K140,0>
Point-to-Point
<K102,0>
RS-232 enabled
<K100,4,0,1,1>
Baud Rate:
9600
; Parity:
None
; Stop Bits:
2
; Data Bits:
8
<K140,5,23>
Polling Mode; Address:
23
<K102,0>
RS-232 Point-to-Point polling
<K143,30>
30 ms Response Timeout
<K100,4,0,1,1>
Baud Rate:
9600
; Parity:
None
; Stop Bits:
2
; Data Bits:
8
<K140,5,12>
Polling Mode; Address:
12
<K148,,08,09,18,0B,0C,0D>
Default RES (0x04), REQ=0x08; EOT=0x09; STX=0x18;
ETX=0x0B; ACK=0x0C; NAK=0x0D
<K102,0>
RS-232 Point-to-Point polling
<K143,40>
40 ms Response Timeout
<K100,9,0,1,1>
Baud Rate:
230K
; Parity:
None
; Stop Bits:
2
; Data Bits:
8
<K140,4>
ACK/NAK
<K147,,,01,1B,2E,1F>
Default RES and REQ (00, disabled); STX=0x01; ETX=0x1B;
ACK=0x2E; NAK=0x1F
<K102,0>
RS-232 enabled
<K143,50>
50 ms Response Timeout
Содержание V430-F-series
Страница 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Страница 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Страница 97: ...4 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 Additional Notes about Calibration ...
Страница 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Страница 265: ...8 30 Auto Focus Multi Code Reader V430 series User s Manual Z392 ISO IEC 29158 Symbol Quality Output ...
Страница 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Страница 325: ...11 18 Auto Focus Multi Code Reader V430 series User s Manual Z392 Request All Configuration Database Settings ...
Страница 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...