7-46
Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
ISO/IEC 29158 Symbol Quality Output 1
Cell Contrast
Cell Contrast Threshold
Cell Moduration
Cell Moduration Threshold
Usage:
Lets the user know if symbol quality is less than acceptable.
Definition:
If enabled, drives
Output
if grade is under
Symbol Contrast Threshold.
Serial Cmd:
<
K890,
output on overall grade, overall grade threshold,
cell contrast,
cell
contrast threshold, cell modulation, cell modulation threshold, fixed pattern
damage, fixed pattern damage threshold, axial non-uniformity, axial non-
uniformity threshold, grid non-uniformity, grid non-uniformity threshold,
unused ECC, unused ECC threshold>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Usage:
Sets the threshold for driving the output.
Definition:
Conforms to ISO/IEC 29158 symbol quality grading (A,B,C,D).
Serial Cmd:
<
K890,
output on overall grade, overall grade threshold, cell contrast,
cell
contrast threshold,
cell modulation, cell modulation threshold, fixed pat-
tern damage, fixed pattern damage threshold, axial non-uniformity, axial
non-uniformity threshold, grid non-uniformity, grid non-uniformity threshold,
unused ECC, unused ECC threshold>
Default:
Grade B
Options:
0 = Grade D
1 = Grade C
2 = Grade B
3 = Grade A
Usage:
Lets the user know if symbol quality is less than acceptable.
Definition:
If enabled, drives
Output
if grade is under
Cell Moduration Threshold.
Serial Cmd:
<
K890,
output on overall grade, overall grade threshold, cell contrast, cell
contrast threshold,
cell modulation,
cell modulation threshold, fixed pat-
tern damage, fixed pattern damage threshold, axial non-uniformity, axial
non-uniformity threshold, grid non-uniformity, grid non-uniformity threshold,
unused ECC, unused ECC threshold>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Usage:
Sets the threshold for driving the output.
Содержание V430-F-series
Страница 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Страница 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Страница 97: ...4 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 Additional Notes about Calibration ...
Страница 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Страница 265: ...8 30 Auto Focus Multi Code Reader V430 series User s Manual Z392 ISO IEC 29158 Symbol Quality Output ...
Страница 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Страница 325: ...11 18 Auto Focus Multi Code Reader V430 series User s Manual Z392 Request All Configuration Database Settings ...
Страница 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...