8-14
Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
Microscan Symbol Quality Output
Decode Time
Pixels Per Element
(Data Matrix Only)
Error Correction Level
(Data Matrix Only)
Matrix Size
(Data Matrix Only)
Definition:
The time in milliseconds required to decode a symbol.
When enabled, the decode time is appended to the symbol data.
Serial Cmd:
<
K710,
percent cell damage,total read time,capture time,locate
time,
decode time
,pixels per element,ECC level,matrix size,quiet
zone,symbol angle
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Definition:
The number of pixels for each element, either dark or light for both
x
and
y
directions.
When enabled, the pixels per element value is appended to the symbol
data.
Serial Cmd:
<
K710,
percent cell damage,total read time,capture time,locate
time,decode time,
pixels per element
,ECC level,matrix size,quiet
zone,symbol angle
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Definition:
Outputs the Data Matrix ECC level.
When enabled, the ECC level is appended to the symbol data.
Serial Cmd:
<
K710,
percent cell damage,total read time,capture time,locate
time,decode time,pixels per element,
ECC level
,matrix size,quiet
zone,symbol angle
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Definition:
Defines the symbol matrix size, in number of pixels in both the
x
and
y
axis.
When enabled, the matrix size value is appended to the symbol data.
Serial Cmd:
<
K710,
percent cell damage,total read time,capture time,locate
time,decode time,pixels per element,ECC level,
matrix size
,quiet
zone,symbol angle
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Содержание V430-F-series
Страница 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Страница 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Страница 97: ...4 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 Additional Notes about Calibration ...
Страница 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Страница 265: ...8 30 Auto Focus Multi Code Reader V430 series User s Manual Z392 ISO IEC 29158 Symbol Quality Output ...
Страница 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Страница 325: ...11 18 Auto Focus Multi Code Reader V430 series User s Manual Z392 Request All Configuration Database Settings ...
Страница 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...