Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
7-23
I/O Parameters
Output State
Pulse Width
Output Mode
Pulse
This is the default mode of operation in which the programmable output is activated when
the
Output On
condition has been met and held active for the duration of the selected
pulse width.
Latch Mode 2
(Unlatch Opposite Condition)
The programmable output is activated when the
Output On
condition has been met and
held active until the opposite condition selected under
Output On
has been met.
For example, if
No-Read
is enabled under
Output On
, the programmable output will go
active on a No-Read and remain active until the opposite condition, a good read, occurs.
Latch Mode 3
(Unlatch Re-enter Read Cycle)
The programmable output is active when the Output On condition has been met and is
held active until a new read cycle begins.
Note:
All of the
Output On
modes are inhibited when any
Output on Warning
is active
for
Output 1
.
Definition:
Sets the active electrical state of the discrete output.
Serial Cmd:
<
K810,
output on,
output state
,pulse width,output mode
>
Default:
Normally Open
Options:
0 = Normally Open
1 = Normally Closed
Definition:
Sets the time in 1 ms increments that the discrete output remains active.
Serial Cmd:
<
K810,
output on,output state,
pulse width
,output mode
>
Default:
500ms
Options:
0 to 65535(in 1 ms increments)
Definition:
Sets the condition in which the discrete output is de-activated.
Serial Cmd:
<
K810,
output on,output state,pulse width,
output mode
>
Default:
Pulse
Options:
0 = Pulse
2 = Latch Mode 2
3 = Latch Mode 3
Содержание V430-F-series
Страница 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Страница 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Страница 97: ...4 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 Additional Notes about Calibration ...
Страница 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Страница 265: ...8 30 Auto Focus Multi Code Reader V430 series User s Manual Z392 ISO IEC 29158 Symbol Quality Output ...
Страница 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Страница 325: ...11 18 Auto Focus Multi Code Reader V430 series User s Manual Z392 Request All Configuration Database Settings ...
Страница 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...