ISO/IEC 15416 Symbol Quality Output
Minimum Reflectance
Minimum Edge Contrast
Modulation
Definition:
Minimum reflectance is calculated and graded for each scan and pro-
vided for the overall grade calculation in accordance with the ISO
15416 specification. The parameter grade and value provided for out-
put is an average value for each measured scan over the entire symbol.
When enabled, the Minimum Reflectance is attached to the symbol out-
put data as a value.
Serial Cmd:
<
K726
, aperture, overall, edge determination, decode, contrast,
mini-
mum reflectance
, minimum edge contrast, modulation, defects, decod-
ability, quiet zone>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Definition:
Contrast measurement assume 8-bit 0 to 255 grey correlate 0 to 100%
reflectance The Minimum Edge Contrast is calculated and graded for
each scan and provided for the overall grade calculation in accordance
with the ISO 15416 specification. The parameter grade and value pro-
vided for output is an average value for each measured scan over the
entire symbol.
When enabled, the Minimum Edge Contrast is attached to the symbol
output data as a value.
Serial Cmd:
<
K726
, aperture, overall, edge determination, decode, contrast, mini-
mum reflectance,
minimum edge contrast
, modulation, defects, decod-
ability, quiet zone>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Definition:
Modulation is calculated and graded for each scan and provided for the
overall grade calculation in accordance with the ISO 15416 specifica-
tion. The parameter grade and value provided for output is an average
value for each measured scan over the entire symbol.
When enabled, the Modulation is attached to the symbol output data as
a value.
Serial Cmd:
<
K726
, aperture, overall, edge determination, decode, contrast, mini-
mum reflectance, minimum edge contrast,
modulation
, defects, decod-
ability, quiet zone>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Содержание V430-F-series
Страница 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Страница 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Страница 97: ...4 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 Additional Notes about Calibration ...
Страница 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Страница 265: ...8 30 Auto Focus Multi Code Reader V430 series User s Manual Z392 ISO IEC 29158 Symbol Quality Output ...
Страница 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Страница 325: ...11 18 Auto Focus Multi Code Reader V430 series User s Manual Z392 Request All Configuration Database Settings ...
Страница 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...