Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
7-69
I/O Parameters
Transfer Optimization
Speed (Lossy)
Images will be saved when possible. Some images may be dropped.
SOR
= Start of Read Cycle
EOR
= End of Read Cycle
Accuracy (Lossless)
Every image in read cycle is transferred. The read cycle may be delayed due to image
saving since each transfer will need to be finished before the end of the read cycle.
SOR
= Start of Read Cycle
EOR
= End of Read Cycle
Definition:
Transfer Optimization
defines how the image is going to be stored in triggered
captured modes.
Serial Cmd:
<
K764,
image storage location,FTP host info,
transfer optimization
,RAM
drive size in MB,save image until,action at image storage limit
>
Default:
Speed
Options:
0 = Speed (Lossy)
1 = Accuracy (Lossless)
Содержание V430-F-series
Страница 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Страница 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Страница 97: ...4 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 Additional Notes about Calibration ...
Страница 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Страница 265: ...8 30 Auto Focus Multi Code Reader V430 series User s Manual Z392 ISO IEC 29158 Symbol Quality Output ...
Страница 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Страница 325: ...11 18 Auto Focus Multi Code Reader V430 series User s Manual Z392 Request All Configuration Database Settings ...
Страница 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...