7-14
Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
Output Indicators
Green Flash Duration
Usage:
Provides visual verification that a good read has occurred.
Definition:
When a good read occurs, the green LEDs will illuminate and stay on for
the time set in the
Green Flash Duration
value.
Serial Cmd:
<
K750,
green flash mode,target pattern status,
green flash duration
>
Default:
25
(250ms)
Options:
0 to 65535 (in 10 ms increments)