9-6
Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
Matchcode Type
Sequential Matching
Match Start Position
Note: Match Start Position
must be set to
1
or greater to enable this feature. A
0
setting
will disable this feature.
Match Length
Usage:
Useful in tracking product serial numbers that increment or decrement
sequentially.
Definition:
With Sequential enabled, Sequential Matching determines if a count is in
ascending (incremental) or descending (decremental) order.
Serial Cmd:
<
K223,
matchcode type,
sequential matching
,match start position,match
length,wild card character,sequence on No-Read,sequence on mismatch
>
Default:
Increment
Options:
0 = Increment
1 = Decrement
Usage:
Match Start Position
is useful in defining specific portions of a symbol
for comparison. For example, if a symbol contains a part number, manufacturing
date, and lot code info, but you are only interested in the part number
information, you can set the reader to sort only the part number and
ignore the other characters.
Definition:
Match Start Position
determines the portions of symbols that will be
matched by defining the first character in the symbol (from left to right)
that will be compared with those of the master symbol, when
Matchcode
Type
is set to
Enabled
or
Sequential
.
Function:
For example, if
Match Start Position
is set to
3
, the first 2 characters
read in the symbol will be ignored and only the 3rd and subsequent
characters to the right will be compared, up to the number of characters
specified by
Match Length
.
Serial Cmd:
<
K223,
matchcode type,sequential matching,
match start position
,
match length,wild card character,sequence on No-Read,sequence on
mismatch
>
Default:
0
Options:
0 to 3000
Usage:
Example:
If
Match Length
is set to
6
in a 10-character symbol, and
Match Start Position
is set to
2
, only the 2nd through 7th characters
(from left to right) will be compared.
Definition:
Defines the length of the character string that will be compared with that
of the master symbol when
Match Start Position
is set to
1
or greater.
When
Match Start Position
is set to
0
, no comparison will occur.
Serial Cmd:
<
K223,
matchcode type,sequential matching,match start position,
match
length
,wild card character,sequence on No-Read,sequence on mismatch
>
Default:
1
Options:
1 to 3000
Содержание V430-F-series
Страница 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Страница 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Страница 97: ...4 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 Additional Notes about Calibration ...
Страница 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Страница 265: ...8 30 Auto Focus Multi Code Reader V430 series User s Manual Z392 ISO IEC 29158 Symbol Quality Output ...
Страница 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Страница 325: ...11 18 Auto Focus Multi Code Reader V430 series User s Manual Z392 Request All Configuration Database Settings ...
Страница 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...