Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
8-25
Symbol Quality
Defects
Decodability
Quiet Zone
Definition:
Defects are calculated and graded for each scan and provided for the
overall grade calculation in accordance with the ISO 15416 specifica-
tion. The parameter grade and value provided for output is an average
value for each measured scan over the entire symbol.
When enabled, the Defects are attached to the symbol output data as a
value.
Serial Cmd:
<
K726
, aperture, overall, edge determination, decode, contrast, mini-
mum reflectance, minimum edge contrast, modulation,
defects
, decod-
ability, quiet zone>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Definition:
Decodability is calculated and graded for each scan and provided for
the overall grade calculation in accordance with the ISO 15416 specifi-
cation. The parameter grade and value provided for output is an aver-
age value for each measured scan over the entire symbol.
When enabled, the Decodability is attached to the symbol output data
as a value.
Serial Cmd:
<
K726
, aperture, overall, edge determination, decode, contrast, mini-
mum reflectance, minimum edge contrast, modulation, defects,
decod-
ability
, quiet zone>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Definition:
Quiet Zone is not an individually processed parameter within the ISO
15416 specification, but it is evaluated as a part of the ISO graded
decode parameters feeding into the overall grade. Quiet Zone is pro-
vided here as average scan result where a passing scan receives an A/
4.0 grade and a fail receives an F/0.0.
When enabled, the Quiet Zone is attached to the symbol output data as
a value.
Serial Cmd:
<
K726
, aperture, overall, edge determination, decode, contrast, mini-
mum reflectance, minimum edge contrast, modulation, defects, decod-
ability,
quiet zone
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Содержание V430-F-series
Страница 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Страница 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Страница 97: ...4 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 Additional Notes about Calibration ...
Страница 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Страница 265: ...8 30 Auto Focus Multi Code Reader V430 series User s Manual Z392 ISO IEC 29158 Symbol Quality Output ...
Страница 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Страница 325: ...11 18 Auto Focus Multi Code Reader V430 series User s Manual Z392 Request All Configuration Database Settings ...
Страница 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...