Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
7-3
I/O Parameters
I/O Parameters Serial Commands
Power On/Reset Counts
<
K406,
power-on,resets,power-on saves,customer default saves
>
Time Since Reset (Read-Only)
<
K407,
hours,minutes
>
Service Message
<
K409,
status,service message,threshold,resolution
>
User-Defined Name
<
K412,
user-defined name
>
Serial Verification
<
K701,
serial command echo status,control/hex output
>
Quality Output
<
K704,
quality output separator,decodes per trigger status
>
Symbol Data Output
<
K705,
status,when to output,symbology identifier status
>
Read Duration Output
<
K706,
status,separator
>
No-Read Message
<
K714,
status,message
>
Output Object Info
<
K734,
output frame number status,output coordinates status
>
LED Configuration
<
K737,
ISO/IEC 16022 grade
>
Output Indicators
<
K750,
green flash LED status,target pattern LED status,green
flash duration
>
EZ Trax Output
<
K757,
EZ Trax Enable,Transfer Port,EZ Trax Image Mode,Image
Format,Image Quality,Object Info Enable,Grade Enable
>
Database Identifier Output
<
K759,
status,separator character
>
Image Push to Host
<
K764,
Image Storage Status,Stored Image Type,Image Storage,
Image File Format,Image Quality,Image Scale,File Save Options
>
Image Push to Host Detail Setup
<
K763,
Image Storage Location,FTP Host Info,Transfer Optimization,
RAM Drive Size in MB,Save Image Until,Action at Image Storage Limit
>
Setup Button
<
K770,
global status,default on power-on,load configuration database,
save for power-on
>
Setup Button Modes
<
K771,
button option 1,button option 2,button option 3,button option 4
>
Trend Analysis Output 1
<
K780,
trend analysis mode,number of triggers,number to output
on,decodes per trigger
>
Trend Analysis Output 2
<
K781,
trend analysis mode,number of triggers,number to output
on,decodes per trigger
>
Trend Analysis Output 3
<
K782,
trend analysis mode,number of triggers,number to output
on,decodes per trigger
>
Diagnostic Output 1
<
K790,
service unit message status
>
Diagnostic Output 2
<
K791,
service unit message status
>
Diagnostic Output 3
<
K792,
service unit message status
>
ISO/IEC 16022 Symbol Quality Output 1
<
K800,
output on symbol contrast,symbol contrast threshold,output
on print growth,print growth threshold,output on axial non-uniformity,
axial non-uniformity threshold,output on Unused ECC,Unused ECC
threshold
>
ISO/IEC 16022 Symbol Quality Output 2
<
K801,
output on symbol contrast,symbol contrast threshold,output
on print growth,print growth threshold,output on axial non-uniformity,
axial non-uniformity threshold,output on Unused ECC,Unused ECC
threshold
>
ISO/IEC 16022 Symbol Quality Output 3
<
K802,
output on symbol contrast,symbol contrast threshold,output
on print growth,print growth threshold,output on axial non-uniformity,
axial non-uniformity threshold,output on Unused ECC,Unused ECC
threshold
>
Output 1 Parameters
<
K810,
output on,output state,pulse width,output mode
>
Output 2 Parameters
<
K811,
output on,output state,pulse width,output mode
>
Output 3 Parameters
<
K812,
output on,output state,pulse width,output mode
>
Содержание V430-F-series
Страница 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Страница 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Страница 97: ...4 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 Additional Notes about Calibration ...
Страница 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Страница 265: ...8 30 Auto Focus Multi Code Reader V430 series User s Manual Z392 ISO IEC 29158 Symbol Quality Output ...
Страница 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Страница 325: ...11 18 Auto Focus Multi Code Reader V430 series User s Manual Z392 Request All Configuration Database Settings ...
Страница 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...