1. DEFINITION 

The “

Bar code

” option enables to install a bar code reader on a second specific 

RS232

 

connector of the

 ATEQ

 instruments.  

It enables on reading of the code to select a test program and eventually to launch the test of 
control (if the option is validated).  

The quantity of characters read by the reader should not exceed 

22

. Beyond the unit will not 

take into account the character string (bar code string).  

1.1. C

OMMUNICATION PARAMETERS CONFIGURATION

 

1.1.1.  Bar code reader configuration 

The Bar Code reader 

must be set with the following communication parameters:  

 

9600

 bauds,  

 

7

 bits,  

 

1

 stop,  

 Parity 

even

The communication parameters of the 

ATEQ

 devices are the same by default and fixed, it's not 

provide to change it. 

 

 

Содержание Gryphon GD4100

Страница 1: ...unch the test of control if the option is validated The quantity of characters read by the reader should not exceed 22 Beyond the unit will not take into account the character string bar code string 1...

Страница 2: ...s Page 2 10 1 1 2 RS232 port configuration From the CONFIGURATION menu select the AUTOMATISM menu and then press the button By using the arrows select the RS232 menu and validate with the key By using...

Страница 3: ...configuration follow this process 1 Enter in programming mode of the reader by flashing this code right hand ENTER EXIT PROGRAMMING MODE 2 Reset the reader to factory settings by flashing this code ri...

Страница 4: ...ange will delete all the learnings That will necessary to learn all the codes for each program From the CONFIGURATION menu select the AUTOMATISM menu and then press the button By using the arrows sele...

Страница 5: ...validate with the key The parameter Char Number corresponds to the quantity of characters or the length of the chain to take into account The sum of the two captured parameters must be lower or equal...

Страница 6: ...de for all the following programs until a new bar code will be readed Adjusted on Yes it will must flash a new bar code before each start cycle In the KEYBOARD SUFFIX parameter check or enter the suff...

Страница 7: ...or check if it checked Press the key the cursor slide to the right hand By using the arrows select Yes and validate with the key The configuration menu appears The NUM parameter is the one that will...

Страница 8: ...cycle menu select the special cycle CODE READER and validate with The device ask for the corresponding test program to the characters strings which be readed and validate with The device confirms the...

Страница 9: ...he captured characters are displayed The code is recorded the device is ready to run At each reading of this code the device will select the corresponding program To see the recorded code for one prog...

Страница 10: ...Pa 01 123456789001XXXXXXXX01 02 02 13 10 2014 20 10 57 02 0 597 bar OK 85 Pa 02 1234567890023333333301 12 12 13 10 2014 20 11 06 12 0 597 bar OK 85 Pa 12 1234567890124444444412 6 2 EXPORT MODE FRAMES...

Отзывы: