7-20

Auto Focus Multi Code Reader V430-series User’s Manual (Z392)

Setup Button Modes

Load New Master

Functions in the same way as new master pin input whenever the associated button 

position is selected. The new master pin’s 

Consecutive Decode

 requirement holds true 

for this function.

Target System

Turns on the target pattern whenever the associated button position is selected. To disable, 

quickly press and release the Setup button.

Note:

 This mode is the only one that does not require that the button be released before 

taking effect. If it is necessary to have the target system on before another operation such 

as calibration or read rate is performed, ensure that the target system mode is assigned a 

lower position so that it will be activated first.

Bar Code Configuration

Enables bar code configuration mode whenever the associated button position is 

selected. When enabled, the imager can accept configuration commands from symbols. 

To disable, quickly press and release the Setup button.

Setup Button Operation

To execute Setup button commands:

Position 1

Hold down button until the 20% LED illuminates.

Position 2

Hold down button until the 20% and 40% LEDs illumi-

nate.

Position 3

Hold down button until the 20%, 40%, and 60% LEDs illuminate.

Position 4

Hold down button until the 20%, 40%, 60%, and 80% LEDs illuminate.

Setup Button

Содержание V430-F-series

Страница 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...

Страница 2: ... Code is a registered trademark of DENSO WAVE INCORPORATED Microsoft product screen shots reprinted with permission from Microsoft Corporation Copyrights All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means mechanical electronic photocopying recording or otherwise without the prior written permission of OMRON Trad...

Страница 3: ...gs 1 8 Step 8 Configure Acquire Settings 1 10 Step 9 Configure Symbology Settings 1 13 Step 10 Format Output and Configure Match String 1 14 Step 11 Configure Output 1 2 and 3 Settings 1 15 Step 12 Run the Application 1 16 V430 series and ESP Software Quick Start 1 17 Step 1 Check Hardware and Connect the System 1 17 Step 2 Mount and Position the Reader 1 18 Step 3 Install ESP 1 19 Step 4 Select M...

Страница 4: ...Hex Values 3 20 Section 4 Calibration Calibration Serial Commands 4 2 Calibration Overview 4 2 Calibration Options 4 3 Calibration by ESP 4 10 Initiating Calibration 4 12 Additional Notes about Calibration 4 13 Section 5 Read Cycle Read Cycle by ESP 5 2 Read Cycle Serial Commands 5 3 Read Cycle Setup 5 4 Multisymbol 5 5 Trigger Mode and Filter Duration 5 6 External Trigger Polarity 5 11 Serial Tri...

Страница 5: ...PDF417 6 38 Composite 6 39 DotCode 6 40 Section 7 I O Parameters I O Parameters by ESP 7 2 I O Parameters Serial Commands 7 3 Symbol Data Output 7 5 No Read Message 7 9 Read Duration Output 7 10 Output Indicators 7 11 LED Configuration 7 15 Serial Verification 7 16 Setup Button 7 17 Setup Button Modes 7 19 Configurable Output 1 7 21 Trend Analysis Output 1 7 24 ISO IEC 16022 Symbol Quality Output ...

Страница 6: ...7 56 Time Since Reset 7 57 Service Message 7 58 User Assigned Name 7 59 Output Object Info 7 60 Database Identifier Output 7 61 Quality Output 7 62 EZ Trax Output 7 63 Image Push to Host 7 66 Image Push to Host Detailed Setup 7 68 Section 8 Symbol Quality Symbol Quality by ESP 8 2 Symbol Quality Serial Commands 8 3 Overview of Symbol Quality 8 4 Symbol Quality Separator Output Mode 8 5 ISO IEC 160...

Страница 7: ...e Settings QSXGA Color Only 10 17 Color Filter 10 18 Focus Setup 10 19 Illumination Brightness 10 21 Morphological Pre Processing 10 22 Morphological Operation and Operator Size 10 23 Damaged Symbol 10 26 Linear Security Level 10 27 Set License 10 28 Section 11 Configuration Database Configuration Database Serial Commands 11 2 Number of Active Indexes 11 3 Configuration Database Status 11 4 Databa...

Страница 8: ...3 16 Default Reset Save 13 19 Reader Status Requests 13 21 Other Operational Serial Commands 13 23 Section 14 Output Format Output Format Serial Commands 14 2 Output Format Status 14 3 Format Assign 14 4 Format Insert 14 7 Output Filter Configuration 14 9 Number of Filters 14 14 Section A Appendices Appendix A General Specifications A 2 Appendix B Serial Commands A 23 Appendix C Communications Pro...

Страница 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...

Страница 10: ...purchase price of the non complying Product provided that in no event shall Omron be responsible for warranty repair indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled stored installed and maintained and not subject to contamination abuse misuse or inappropriate modification Return of any Products by Buyer must ...

Страница 11: ...mmable Products Omron Companies shall not be responsible for the user s programming of a programmable Product or any consequence thereof z Performance Data Data presented in Omron Company websites catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty It may represent the result of Omron s test conditions and the user must cor...

Страница 12: ...result in minor or moderate injury or may result in serious injury or death Additionally there may be significant property damage Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury or in property damage General Prohibition Indicates general prohibitions including warnings for which there is no specific symbol General Caution Indicates general ca...

Страница 13: ... light that may have an adverse effect on the eyes do not stare directly into the light emitted from the LED If a specular object is used take care not to allow reflected light enter your eyes Please take external safety measures so that the system as a whole should be on the safe side even if a failure of a this product or an error due to an external factor occurred An abnormal operation may resu...

Страница 14: ...perating systems financial settlement systems and other applications that handle rights and property c Applications under severe condition or in severe environment including but not limited to outdoor equipment equipment exposed to chemical contamination equipment exposed to electromagnetic interference and equipment exposed to vibration and shocks d Applications under conditions and environment n...

Страница 15: ...e product Always turn OFF the power of the reader and peripheral devices before connecting or disconnecting a cable Connecting the cable with power supplied may result in damage of the reader or peripheral devices Do not apply torsion stress to the cable It may damage the cable Secure the minimum bending radius of the cable Otherwise the cable may be damaged Do not attempt to dismantle repair or m...

Страница 16: ...s Place not affected by strong electro magnetic waves Place not near to high voltage or high power equipment For good heat dissipation keep the distance Do not install the product immediately above significant heat sources such as heaters transformers or large capacity resistors Do not let the ambient temperature exceed an operating temperature range Provide a forced air fan cooling or air conditi...

Страница 17: ... cloth Do not use thinners or benzene To ensure safe access for operation and maintenance separate the reader as much as possible from high voltage equipment and power machinery After confirming that this product is started up communicate with the high order device When this product has started up an indefinite signal may be output from the high order interface To avoid this problem clear the rece...

Страница 18: ...the standards below EC Directive 2004 108 EC Until April 19 2016 EU Directive 2014 30 EU After April 20 2016 EN61326 1 Electromagnetic environment Industrial electromagnetic environment EN IEC 61326 1 Table 2 This product complies with EC EU Directives EMC related performance of the OMRON devices that comply with EC EU Directives will vary depending on the configuration wiring and other conditions...

Страница 19: ...Manual Z392 Revision History A manual revision code appears as a suffix to the catalog number on the front and back covers of the manual Revision code Date Revised content 01 March 2018 Original production 02 April 2018 Corrected mistakes Cat No Z392 E1 02 Revision code ...

Страница 20: ...nterface provides more detailed information This manual s primary focus is the firmware and ESP Software V430 series and WebLink Quick Start 1 2 Step 1 Check Hardware and Connect the System 1 2 Step 2 Mount and Position the Reader 1 4 Step 3 Connect to WebLink 1 4 Step 4 Explore the Start View 1 5 Step 5 Create a New Setup or Load an Existing Setup 1 6 Step 6 Explore the Setup View 1 7 Step 7 Conf...

Страница 21: ...are and Connect the System Note The V430 series can be configured as an RS 232 reader with the V430 W2 3M cable Item Description Model Number 1 V430 F V430 F 2 Power Supply 100 240VAC 24VDC M12 12 Pin Socket V430 W8 3M 3 Cordset Host Ethernet M12 8 Pin Plug Screw On to RJ45 3 m V430 WE 3M 1 V430 series Standalone Ethernet Configuration To Power To Host 2 3 ...

Страница 22: ...ct specular reflection Symbols can be rotated tilted at any angle however for best results symbols should be aligned with the field of view In the case of linear symbols aligning the bars in the direction of their movement ladder orientation will minimize the chances of blurring and will result in more consistent decodes Important Avoid excessive skew or pitch Maximum skew is 30 maximum pitch is 3...

Страница 23: ...wser and type the reader s default IP address http 192 168 188 2 in the web browser s address bar The reader will connect to WebLink V430 series DHCP Network Connection 1 Plug your reader into the your network adapter 2 Open DDU Device Discovery Utility Software and connect to the V430 series via Ethernet TCP IP DDU can be used to confirm and change of the connected reader information and communic...

Страница 24: ...AC ID Firmware Version Sensor Optics Decoder and Speed This view allows you to choose Assisted Setup to Create a New Setup or to Load a Setup Click the gear icon to open the Application Settings menu which gives you access to several functions Save New Load Advanced Language Terminal Beeper Guided Tour Image Storage Restore Default Settings Manage Login Enable USB Drive Mode and About WebLink Note...

Страница 25: ...etup automatically Once the setup is created you can fine tune its parameters in the Setup view Create a New Setup The Start view also allows you to Create a New Setup without using Assisted Setup When you click the Create a New Setup button WebLink searches for any differences from default in the reader parameters If no differences from default are found you will see the Setup view If differences...

Страница 26: ...s and Favorites Clicking the Save icon at the upper right saves current settings to the reader s flash memory so the settings will be available when the reader is rebooted The question mark icon at the upper right opens WebLink Help The gear icon at the upper right brings up the Application Settings menu Start and Stop Trigger Only shown when in Trigger Mode WOI Auto Photometry Optimize Autofocus ...

Страница 27: ...ameters Presentation This mode uses Continuous Read Auto along with Continuous Capture Mode and a Timeout at End of Read Cycle Green Flash Mode is set to Static Presentation and the Green Flash Duration is set to 1 second Continuous This mode allows you to set the Read Cycle Timeout and the expected Number of Symbols from 1 to 100 Triggered This mode sets the read cycle to Serial Data and Edge End...

Страница 28: ...hat the trigger is disabled Serial Trigger Non Delimited On When Serial Trigger is set to On the start and stop characters are set to S and E When the trigger button is clicked it will use the current start and stop non delimited triggers Custom This mode allows you a wider variety of read cycle scenarios including Continuous Read Auto Use this mode to select Trigger mode and to set Serial Trigger...

Страница 29: ...d only The A shown on the sun and dial icons signifies that Auto Photometry is enabled Auto Photometry constantly determines the best Exposure and Gain settings during each read cycle Autofocus Autofocus can be enabled and disabled in the Image Area using the focus button in the Device Control Toolbar and can be configured in the Acquire section of the Setup view While in Continuous mode or Contin...

Страница 30: ...us icons appear When you click the Spot Focus icon the Select a location in the image to autofocus message appears The cursor transforms into crosshairs as shown in the example below This allows you to select the section of the image in which you want to perform a quick focus Note If you click the Autofocus button to the left of the Spot Focus button the reader will switch from Spot Focus to regul...

Страница 31: ... Dark increases the light cell size of a symbol It is useful for increasing the light cell size of a light on dark Data Matrix symbol Connect Dark Connect Dark removes minor light defects of dark cells Separate Dark Separate Dark removes minor dark defects of light cells Operator Size The Operator Size dropdown menu determines the size of the area or pixel neighborhood in which the enhance operati...

Страница 32: ...bottom of the Decode dialog brings up Symbology Settings This allows you to configure every parameter for every available code type Data Matrix error correction parameters are shown in this example but you can configure any parameter for any of the code types supported by WebLink All parameter changes for all code types take effect immediately ...

Страница 33: ...the Setup view allows you to determine the many ways in which barcode data can be formatted and parsed before it is output as a data string You can also set Preamble and Postamble in this dialog Match Options and Match String Database accessible by clicking the Match String section in the Setup view allow you to set the match code mode text output new master and match string database ...

Страница 34: ... section at the lower left of the Setup view For each output you can determine the Output On behavior Mode Pulse Width and State Outputs 2 and 3 also allow you to determine output behavior based on Trend Options parameters or Verification Options parameters This example shows the dialog that appears when you click Symbol Quality Options A similar dialog would appear for Trend Options under Output ...

Страница 35: ...e setup as it follows the parameters you have defined The right panel of the UI shows Counts for Cycles Reads No Reads and Mismatches as well as Rate information for Capture Decode Overhead Total Read and Trigger Rate as well as Output Data A filmstrip below the Image Area shows each image capture with a green check mark for a good read and a red x for a no read ...

Страница 36: ...nnect the System Note The V430 series can be configured as an RS 232 reader with the V430 W2 3M cable Item Description Model Number 1 V430 F V430 F 2 Power Supply 100 240VAC 24VDC M12 12 Pin Socket V430 W8 3M 3 Cordset Host Ethernet M12 8 Pin Plug Screw On to RJ45 3 m V430 WE 3M 1 V430 series Standalone Ethernet Configuration To Power To Host 2 3 ...

Страница 37: ...e of direct specular reflection Symbols can be rotated tilted at any angle however for best results symbols should be aligned with the field of view In the case of linear symbols aligning the bars in the direction of their movement ladder orientation will minimize the chances of blurring and will result in more consistent decodes Important Avoid excessive skew or pitch Maximum skew is 30 maximum p...

Страница 38: ...lso be installed from the Download Center located at www microscan com Follow the prompts to install ESP from the Microscan Tools Drive or Download Center Click the ESP icon on your desktop to run the program Minimum System Requirements 233 MHz Pentium PC Windows 8 7 operating system 32 bit or 64 bit Internet Explorer 6 0 or higher 128 MB RAM or greater 160 MB free disk space 800 x 600 256 color d...

Страница 39: ...r double click one of the buttons to select your reader 3 Depending on the model you have selected you will see the appropriate Would you like to connect to the XX dialog after selecting your reader and clicking OK 4 Click Yes when asked if you would like to connect Note If you need to select another model later click the Switch Model button near the top of the screen or use Model New Model in the...

Страница 40: ... Quick Start Note If you connect to the V430 F you need to select the MicroHAWK ID 40 once Click No when asked if you would like to connect the MicroHAWK ID 40 Click Connect on the menu toolbar and then select Connection Wizard Click Con nect when you see the dialog ...

Страница 41: ...nication interface required by your application Configure settings as required by the application and click Connect When a connection is established the green indicator in the status bar at the bottom right of the screen will be visible Important For best connection results be sure that no decodable symbols are within the reader s field of view while attempting to connect ...

Страница 42: ...e field of view will appear in the video view beneath the Locate and Calibrate buttons and you will see the blue target pattern projected from the front of the reader Center the target pattern on the symbol Important The entire symbol should fall within the field of view FOV of the reader The field of view is what appears in ESP s Locate Calibrate window in EZ Mode Click the Stop button to end the...

Страница 43: ...mpletion of this routine a green LED pattern will flash brightly and illuminate the symbol Calibrate by ESP Click the Calibrate button The reader will search camera settings to determine the best configuration for decoding symbol data A successful calibration will display a green frame around the symbol and the following message will appear Uploading all reader parameters After a moment the symbol...

Страница 44: ... been successfully decoded the symbol s data and related features will be presented in the field below the image display window Also while the symbol is being inspected the Read Rate LEDs will indicate the corresponding Read Rate percentage on the back of the unit 2 To end the test click the Stop button Note Read Rate can also be tested using the Read Rate interface in Utilities Test Read Rate by ...

Страница 45: ...n the model menu to return to a previous reader model or to remove a previous reader model Click Parameters to show the tabbed tree controls for Communication Read Cycle Symbologies I O Parameters Symbol Quality Matchcode and Diagnostics Click Setup to access a Camera Setup tree control and the tabbed user interfaces for Video Evaluation Calibration WOI Window of Interest Configuration Database Or...

Страница 46: ...anges in current memory and saves to the reader for power on 1 Left click on the to expand the desired tree 2 Double click on the desired parameter and click once in the selection box to view options 5 Right click on the open screen and select Save to Reader to implement the command in the reader 4 Left click again on the open screen to complete your selection 3 Place your cursor in the selection ...

Страница 47: ...ce WD 000 Auto Focus 050 50 mm 081 81 mm 102 102 mm Optics W Standard Density Wide View M High Density Middle View N Ultrahigh Density Narrow View Color Monochrome M Monochrome C Color Effective pixels 50 5 0 Megapixel QSXGA 2592 x 1944 12 1 2 Megapixel SXGA 1280 x 960 03 0 34 Megapixel WVGA 752 x 480 Auto Focus Multi Code Reader V430 F series ...

Страница 48: ...nu contains a list of all commands and command parameters that pertain to that specific element of reader operation For example the I O Parameters menu shows a Calibration Options command which corresponds to the K529 serial command and then a list of the parameters Gain Exposure Symbol Type Window of Interest Framing Window of Interest Margin Linescan Height and Processing Each of these parameter...

Страница 49: ...er Second is unchecked the test will count the percentage of decodes relative to the number of actual scans Click Stop to end the test Calibrate The calibration routine that will optimize the reader by comparing Read Rates at various camera and image processing settings Starts Read Rate test Click Calibrate to begin the initial calibration routine Calbration is explained at the left of the EZ Mode...

Страница 50: ...n above in the operations bar or configuration bar see the corresponding sections of this manual Decoded symbol data is shown in this table Return to EZ Mode Video Evaluation Calibration Window of Interest Configuration Database Ordered Output Output Format Dynamic Setup Click on tabs in this row to access configuration trees like the one shown here Communication Read Cycle Symbologies I O Paramet...

Страница 51: ...elected the ESP configuration is saved to the host computer s hard drive and available whenever the same file is selected under Open Important When you save menu changes to your hard drive these changes are not saved to your reader Import Export Import converts the ASCII settings from a text file to ESP configuration settings Export converts the active ESP configuration settings to an ASCII text f...

Страница 52: ...the models supported by ESP When you choose a different model the connection to your present model will be terminated To connect to another model select New Model choose a new model from the pop up menu that appears and click OK Note When you save a esp file you are saving the settings of all models defined in that file ...

Страница 53: ...e model menu displaying all supported readers Show Connect Prompt At startup displays the Would you like to connect to the MicroHAWK ID prompt Receive After Connect At startup loads the reader s settings into ESP This is not recommended if you want to preserve your ESP settings for future use Skip EZ Mode At startup skips EZ Mode and opens directly in App Mode Enable Send and Save as Customer Defa...

Страница 54: ...keystroke to send a trigger character select F2 then in the Ctrl row enter trigger character and click OK Then whenever the Ctrl F2 keystroke is pressed the trigger character will start the read cycle Note The F1 key is reserved for opening ESP Help and the F3 key is reserved for the Find Next function Change Font Allows you to modify the font used for decode data received from the reader on the T...

Страница 55: ...oolbar Preferences Bar Code Options Tab The Bar Code Options dialog allows you to set the size of user created symbols Sizing Information Sets the bar width or module width in mils or thousandths of an inch of user created symbols Example A bar width of 18 is 0 018 inches ...

Страница 56: ... Do Not Send or Receive Settings creates a condition in which Auto Sync will not automatically send reader settings to ESP or send ESP settings to the reader Show Target Pattern During Locate Allows you to determine whether the blue LED target pattern will be on or off during the Locate routine Show Target Pattern During Calibrate Allows you to determine whether the blue LED target pattern will be...

Страница 57: ...ts the user to save a esp file when ending a session The esp file will be saved in the location of your choice Connect to Readers via TCP IP When enabled shows a TCP IP option on the Connection Wizard Note There is no change while being showed in case of V430 F Use Default Storage Location When enabled automatically stores data in ESP s Application Data folder ...

Страница 58: ...he information you type in the Model Memo field will appear in a context sensitive text box whenever your cursor hovers over the Model Memo item on the Options menu Memos created in Model Memo are specific to the model enabled when the message was created Note Memos must be saved in a esp file if you want them to available in your next session If you do not save your current session any memos that...

Страница 59: ...ction Wizard To connect using the Connection Wizard Click Connect on ESP s menu toolbar and then select Connection Wizard Select the communication interface required by your application Configure settings as required by the application and click Connect When a connection is established the green indicator in the status bar at the bottom right of the screen will be visible If your RS 232 connection...

Страница 60: ... text you wish to encode This is a useful tool for creating configuration symbols allowing you to configure your reader by reading the symbols you create Create a caption for the symbol that matches the encoded data or write your own caption Drag specific configuration values from the control tree directly into this field to encode new symbols The symbol you create will be displayed in the field a...

Страница 61: ...lick on the to expand menu items 2 Double click the desired parameter and single click in the selection box to view options 3 Place your cursor in the selection box scroll down to the setting you want to change and single click the setting 4 Left click again on the open screen to complete the selection 5 Right click on the open screen and select Save to Reader to implement the command in the reade...

Страница 62: ... you want to receive upload the reader s settings and save them as a file for future use For example if your reader has settings that you do not want to change choosing Yes would allow you to load those settings to ESP and save them in an ESP file for later retrieval Receiving the reader s settings will also assure that you will not be subsequently saving any unwanted changes that you or someone e...

Страница 63: ...n After you perform a Receive Reader Settings command1 and you click on the Add Exception option you may see a list of serial commands These are commands that may be in your reader s firmware but not included in or different from your current version of ESP You can edit these commands by double clicking on them and changing them as needed It is important to note that these commands will be saved t...

Страница 64: ...e reader The user can also send serial commands to the reader via Terminal window Communications by ESP 3 2 Communications Serial Commands 3 3 Host Port Connections 3 4 Host Port Protocol 3 5 ACK NAK Options 3 6 Polling Mode Options 3 7 Ethernet 3 8 Response Timeout 3 13 LRC Longitudinal Redundancy Check Status 3 14 Protocol Configuration Examples 3 15 Preamble 3 16 Postamble 3 17 EtherNet IP Byte...

Страница 65: ...s Manual Z392 Communications by ESP Communications by ESP Click the Parameters button and then the Communication tab To open nested options single click the To change a setting double click the setting and use your cursor to scroll through the options ...

Страница 66: ...Ports K127 TCP Port 1 TCP Port 2 Search and Configure Mode K128 status timed window EtherNet IP K129 status Host Protocol K140 protocol address Preamble K141 status preamble characters Postamble K142 status postamble characters Response Timeout K143 response timeout LRC Status K145 status ACK NAK Options K147 RES REQ STX ETX ACK NAK Polling Mode Options K148 RES REQ STX ETX ACK NAK EtherNet IP Byt...

Страница 67: ...tions 0 600 1 1200 2 2400 3 4800 4 9600 5 19 2K 6 38 4K 7 57 6K 8 115 2K 9 230 4K Usage Only changed if necessary to match host setting Definition An error detection routine in which one data bit per character is set to 1 or 0 so that the total number of bits in the data field is either even or odd Serial Cmd K100 baud rate parity stop bits data bits Default None Options 0 None 1 Even 2 Odd Usage ...

Страница 68: ...define the sequence and format in which information is transferred between the reader and the host Serial Cmd K140 protocol address Default Point to Point Options 0 Point to Point 4 ACK NAK 5 Polling Mode Usage Used only with RS 232 Definition Standard Point to Point requires no address and sends the data to the host whenever it is available without a request or handshake from the host Serial Cmd ...

Страница 69: ...ACK NAK Sent when LRC ETX postamble command ending angle bracket or timeout waiting for more data are detected depending on what is enabled As with Polling Mode K140 5 the reader can optionally perform the REQ and RES event sequences in ACK NAK mode If the sender does not receive an ACK or NAK it will send REQ to request such a response if enabled When the sender receives an ACK too many NAKs or t...

Страница 70: ...dependent of the ACK NAK Options K147 The values of protocol characters can be changed but the protocol events cannot be disabled The polling mode address is configured in the K140 command see Poll Address If RS 232 is enabled K102 0 Polling Mode will operate as a Point to Point polling protocol This is because the RS 232 transmitter is always left on when enabled Serial Cmd K148 RES REQ STX ETX A...

Страница 71: ...nual Z392 Ethernet Ethernet Enables or disables Ethernet connectivity in the reader This corresponds to the K126 command It requires a Zrdall to return to default settings IP Address This is the IP address of the reader when it is in Static IP Address Mode ...

Страница 72: ...Reader V430 series User s Manual Z392 3 9 Communications Subnet This is the subnet of the reader when it is in Static IP Address Mode Gateway This is the gateway IP address of the reader when it is in Static IP Address Mode ...

Страница 73: ...de Determines how the reader s IP address will be defined Static In Static Mode the reader uses the user defined IP address This is the default state for V430 series DHCP In DHCP Mode the reader automatically acquires the IP address Subnet and Gateway addresses from a DHCP or BOOTP server ...

Страница 74: ...ser s Manual Z392 3 11 Communications TCP Port 1 One of two TCP ports for Ethernet communication with the reader The default setting is 2001 TCP Port 2 One of two TCP ports for Ethernet communication with the reader The default setting is 2003 ...

Страница 75: ... Once this setting is Disabled ESP will only be able to connect to the reader if you know the IP address and enter it in the IP Address field of the Ethernet TCP IP connect dialog Search and Configure Mode can be re enabled by defaulting the reader Enabled When enabled Search and Configure Mode will find the reader and settings can be changed Timed Window When Timed Window is selected Search and C...

Страница 76: ...from the host The reader can be set to wait indefinitely by setting Response Timeout to zero Definition The time that the reader will wait before timing out if ACK NAK and ETX are enabled and a host response is expected Serial Cmd K143 response timeout Default 12 in 1 ms increments Options 0 to 255 A zero 0 setting causes an indefinite wait ...

Страница 77: ... following the STX start of text up to and including the ETX end of text What this means is that the binary representation of all the characters in a transmission are cumulatively added in a column and each resulting odd integer is assigned a 1 and each even integer a 0 two 1s 0 two 0s 0 a 1 and a 0 1 The extra LRC character is then appended to the transmission and the receiver usually the host pe...

Страница 78: ...its 8 K140 5 23 Polling Mode Address 23 K102 0 RS 232 Point to Point polling K143 30 30 ms Response Timeout K100 4 0 1 1 Baud Rate 9600 Parity None Stop Bits 2 Data Bits 8 K140 5 12 Polling Mode Address 12 K148 08 09 18 0B 0C 0D Default RES 0x04 REQ 0x08 EOT 0x09 STX 0x18 ETX 0x0B ACK 0x0C NAK 0x0D K102 0 RS 232 Point to Point polling K143 40 40 ms Response Timeout K100 9 0 1 1 Baud Rate 230K Pari...

Страница 79: ...ed on its own line Definition Defines a one to four character data string that can be added to the front of the decoded data Serial Cmd K141 status preamble character s Default Disabled Options 0 Disabled 1 Enabled within any protocol Serial Cmd K141 status preamble character s Default M corresponds to carriage return Options To enter control characters within a serial command hold down the Ctrl k...

Страница 80: ...s own line Definition Allows the user to enable or disable up to four postamble characters that can be added to the end of the decoded data Serial Cmd K142 status postamble character s Default Enabled Options 0 Disabled 1 Enabled within any protocol Serial Cmd K142 status postamble character s Default M J corresponds to carriage return line feed Options To enter control characters within a serial ...

Страница 81: ...30 series User s Manual Z392 EtherNet IP Byte Swapping Enabled EtherNet IP Byte Swapping Enabled Definition Enables or disables EtherNet IP byte swapping for decode data Serial Cmd K163 status Default Disabled Options 0 Disabled 1 Enabled ...

Страница 82: ...ulti Code Reader V430 series User s Manual Z392 3 19 Communications PROFINET Definition Enables or disables the PROFINET communications protocol Serial Cmd K164 status Default Disabled Options 0 Disabled 1 Enabled ...

Страница 83: ...ASCII character Example Consider the Postamble command Imagine that your application requires the ASCII character to be the postamble in your symbol decode output The ASCII characters and can only be entered as hex values So to make the postamble in your symbol decode output enter the Postamble command as follows K142h 3E Note that the status field contains only a This is because the only field th...

Страница 84: ...s This section shows the calibration options and explains the different ways that those options can be configured Calibration Serial Commands 4 2 Calibration Overview 4 2 Calibration Options 4 3 Calibration by ESP 4 10 Initiating Calibration 4 12 Additional Notes about Calibration 4 13 ...

Страница 85: ...ated by serial command or in the ESP user interface When the reader enters calibration it runs through an optimization cycle that sets the ideal parameters for reading symbols at the highest possible level of performance Calibration can be specially configured to optimize specific parameters such as gain exposure and symbol type Calibration Options K529 gain exposure focus position symbol type WOI...

Страница 86: ...symbol be placed in the field of view as feedback from the symbol decoding process is used to select the best gain setting If a symbol is not decoded the process will result in a fail condition Gain is enabled by default Quick Calibrate Quick Calibrate uses the automatic gain control AGC feature of the image sensor to adjust the gain value such that the current image falls into a desirable region ...

Страница 87: ...elect the best exposure setting If a symbol is not decoded the process will result in a fail condition Exposure is enabled by default Quick Calibrate Quick Calibrate uses the automatic exposure control feature of the image sensor to adjust the exposure value such that the current image falls into a desirable region of the image sensor s sensitivity range ensuring optimal image luminance The image ...

Страница 88: ...mplished with minimal image processing by analyzing a histogram of the image frame Before performing focus calibration a value for exposure and gain is determined The process then steps through the focus range of the system capturing the required number of image frames for each focal position Then a histogram is performed on each image frame and the histogram results for each focal position are av...

Страница 89: ... except PDF417 and Pharmacode will be attempted during calibration Any new symbologies successfully decoded during calibration will remain enabled at the end of the process All enabled symbologies will remain enabled For example assume that only Code 39 is enabled at the beginning of calibration If a Code 128 symbol is decoded during calibration then Code 128 as well as Code 39 will be enabled Ser...

Страница 90: ...l plus an additional margin area around the symbol determined by the WOI Margin parameter Column If the calibration process is successful the Window of Interest columns will be modified to vertically frame the symbol plus an additional margin area around the symbol determined by the WOI Margin parameter Definition If WOI Framing is enabled the camera s Window of Interest will be set to a full size...

Страница 91: ...will be set by the scan height parameter and will be configured for full row resolution If the symbol is horizontal the image row size will be set by the scan height parameter and will be configured for full column resolution The scan line will be centered in the middle of the symbol If the symbol is tilted such that the scan line will not pass completely through the symbol the scan width will be ...

Страница 92: ...expressed in number of pixels If the margin causes the image to exceed the maximum image size it will be reduced accordingly Serial Cmd K529 gain exposure focus position symbol type WOI framing WOI margin line scan height processing Default 75 pixels Options 20 to 1280 Definition This parameter is only used with the Straight Line modes It sets the scan height of the straight line image and it is e...

Страница 93: ...nd after the calibration routine Determines the amount of time and effort the reader will spend attempting to decode a symbol for each parameter configuration Low Medium High Definable Exposure Gain and Image Quality values are all tracked in real time during the calibration process Initiates the calibration routine Cancels the calibration process if necessary The Window of Interest section of the...

Страница 94: ...e process has been completed Saves the optimal configuration parameters determined by calibration results The Shutter Gain and Quality indicator bars remain stationary at the end of calibration to provide a visual reference for the final values of these parameters Notice the improved image resolution after the calibration process is complete ...

Страница 95: ... serial command or from the Calibration interface in ESP A symbol must be in the reader s field of view during the calibration process In ESP the Calibrate button starts the calibration routine Note If you choose to calibrate the reader by sending a CAL command a decode is also required for the calibration process to be completed successfully ...

Страница 96: ... then code length 1 will be set to the decoded symbol length at the end of calibration Otherwise the symbol lengths will be restored to their original configurations 4 Pharmacode is not calibrated 5 All symbol types that were enabled before calibration will still be enabled after calibration For example if Data Matrix ECC 200 was enabled before calibration and the calibration routine was performed...

Страница 97: ...4 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 Additional Notes about Calibration ...

Страница 98: ...s section explains those parameters Read Cycle by ESP 5 2 Read Cycle Serial Commands 5 3 Read Cycle Setup 5 4 Multisymbol 5 5 Trigger Mode and Filter Duration 5 6 External Trigger Polarity 5 11 Serial Trigger 5 12 Start Trigger Character Non Delimited 5 13 Stop Trigger Character Non Delimited 5 14 End of Read Cycle 5 15 Capture Mode 5 17 Capture Timing 5 22 Image Processing Timeout 5 24 Image Stor...

Страница 99: ... User s Manual Z392 Read Cycle by ESP Read Cycle by ESP To change a setting double click the setting and use your cursor to scroll through the options To open nested options single click the Click the Parameters button and then the Read Cycle tab ...

Страница 100: ...mber of symbols multisymbol separator Start Trigger Character K229 start character Stop Trigger Character K230 stop character Capture Mode K241 capture mode number of rapid captures rapid capture mode number of continuous captures images per read cycle limit read cycle history limit Capture Time K242 time before first capture time between captures 1 and 2 timebetween captures 2 and 3 time between ...

Страница 101: ...le The reader can read mul tiple symbols in a single image frame 2 Decide on the trigger type to be used if serial choose a serial character if external choose either Level or Edge 3 Designate how the read cycle should end Timeout New Trigger Last Frame 4 Select Capture Mode Continuous Mode or Rapid Mode 5 Select Number of Captures if in Rapid Capture Mode 6 Set the Time Before First Capture and T...

Страница 102: ...read cycle is 3 000 for all symbols All No Read messages are posted at the end of the data string unless output filtering is enabled If more than one symbol is within the field of view at the same time symbol data may not be displayed in the order of appearance If Matchcode Type is set to Sequential or if Trigger is set to Continuous Read 1 Output the reader will behave as if Number of Symbols wer...

Страница 103: ...ul in testing symbol readability or reader functions It is not recommended for normal operations Definition In Continuous Read trigger input options are disabled the reader is always in the read cycle and it will attempt to decode and transmit every capture If a single symbol stays within read range for multiple read cycles its data will be transmitted repeatedly until it leaves the read range The...

Страница 104: ...ion It is also effective in applications where the objects are presented by hand Definition In Continuous Read 1 Output the reader self triggers whenever it decodes a new symbol or a timeout occurs If End of Read Cycle is set to Timeout and the symbol doesn t change the output is repeated at the end of each timeout period For example if Timeout is set to one second the reader sends the symbol data...

Страница 105: ...ges again Serial Cmd K200 2 Usage This mode is highly recommended in any application where conveying speed is constant or if spacing object size or read cycle timeouts are consistent Definition External Edge as with Level allows the read cycle active state to begin when a trigger change of state from an external sensing device is received However the passing of an object out of sensor range does n...

Страница 106: ...s are entered inside angle brackets as shown here t Serial Cmd K200 4 Usage Serial Data or External Edge is seldom used but can be useful in an application that primarily uses an external sensing device but occasionally needs to be triggered manually Definition In this mode the reader accepts either a serial ASCII character or an external trigger pulse to start the read cycle Serial Cmd K200 5 Def...

Страница 107: ...gger will occur Serial Cmd K200 trigger mode leading edge trigger filter trailing edge trigger filter Default 1 Options 1 to 65535 Trigger filter range 32 0 µs to 2 10 seconds Usage Used to ignore spurious triggers when Trigger Mode is set to External Edge or External Level Definition To consider a change in state on the trigger input the level must be stable for the trigger filter duration In an ...

Страница 108: ...l Trigger Polarity Usage Allows users to select the trigger polarity that will be used in their application Definition Determines the active state of the trigger signal applied to the cable input of the reader Serial Cmd K202 active state Default Positive Options 0 Negative 1 Positive ...

Страница 109: ...gle bracket delimiters or in the case of non delimited triggers it must define individual start and stop characters Usage Allows the user to define the trigger character that initiates the read cycle Definition A single ASCII host serial trigger character that initiates the read cycle A delimited trigger character is one that either starts or ends the read cycle and is enclosed by delimiters such ...

Страница 110: ... apply In External Edge the reader looks only for the Start trigger character and ignores any Stop trigger character that may be defined In External Level the Start trigger character begins the read cycle and the Stop trigger character ends it Note that even after a symbol has been decoded and the symbol data transmitted the reader remains in External Level trigger read cycle until a Stop characte...

Страница 111: ... the following rules apply In External Edge the reader looks only for the Start trigger character and ignores any Stop trigger character that may be defined In External Level the Start trigger character begins the read cycle and the Stop trigger character ends it Note that even after a symbol has been decoded and the symbol data transmitted the reader remains in External Level trigger read cycle u...

Страница 112: ... effective in highly controlled applications when the maximum length of time between objects can be predicted It assures that a read cycle ends before the next symbol appears giving the system extra time to decode and transmit the data to the host Definition Timeout ends the read cycle causing the reader to stop reading symbols and send the symbol data or No Read message when the time set in Timeo...

Страница 113: ... trigger Usage Useful in applications that require an alternative way to end the read cycle For example if an assembly line should stop completely or the intervals between objects are highly irregular Definition Timeout or New Trigger is identical to Timeout except that a timeout or a new trigger whichever occurs first ends the read cycle Usage Useful in applications in which the number of capture...

Страница 114: ...ime between captures parameter In this mode the only limiting time factor is integration and transfer timing Usage Continuous Capture is useful in applications with slower line speeds or where symbol spacing may be random or not time dependent Definition In Continuous Capture Mode image captures are taken throughout the read cycle in a multi buffered format see diagram below The reader begins proc...

Страница 115: ...pid Capture Mode Usage Number of Captures is used to specify the number of captures to be processed in Rapid Capture Mode Definition Sets the total number of captures that are processed during a read cycle in Rapid Capture Mode This feature is used in conjunction with Capture Timing parameters to specify the capture sequence of a rapid capture read cycle Serial Cmd K241 capture mode number of capt...

Страница 116: ... is required Definition In Timed Rapid Capture decoding occurs independent of and simultaneous with capturing thus allowing precise timing or no delay at all between captures Also consecutive captures are regarded as the same symbol if the output data is the same Start of Read Cycle No Time Delay Between Captures n End of read cycle Time Delay Between Captures Time Before First Capture Diagram B D...

Страница 117: ...ue until the predetermined Number of Captures is met or until the predetermined End of Read Cycle condition is met whichever occurs first Note If End of Read Cycle is set for New Trigger and the read cycle qualifications have not been met the read cycle will only end once it receives the first trigger after reaching the predetermined Number of Captures setting Processing Read cycle ends on New Tri...

Страница 118: ...e limit read cycle history Default 2 Options 1 and 255 Definition Specifies the number of captures to process in a read cycle Serial Cmd K241 capture mode number of captures rapid capture mode number of continuous captures images per read cycle limit read cycle history Default 10 Options 3 and 255 Definition Specifies the number of images that can be stored in read cycle history Serial Cmd K241 ca...

Страница 119: ...l will be in the reader s field of view at the beginning of the capture sequence Definition Time Before First Capture in a moving line application is the time between an external trigger event and the occurrence of the first capture Serial Cmd K242 time before 1st capture time between capture 1 and capture 2 time between capture 7 and capture 8 Default 0 Options 0 to 65535 2 097 seconds in 32 µS i...

Страница 120: ...ime before 1st capture time between captures time 1 time 2 time7 Entering 0s will result in no time between captures Entering a different value in each field will vary the time delays accordingly Note You must enter time values along with comma separators for each field you want to change If you omit fields or enter only commas the fields will remain as previously set Important If the reader is co...

Страница 121: ... tried to ensure that the symbol is decoded successfully Usage Useful in higher speed applications where image processing time is long enough that not all captures have an opportunity to be processed Definition Specifies the maximum amount of time to process a captured image When the timeout expires the image processing is aborted This timeout works in both Rapid Capture and Continuous Capture mod...

Страница 122: ...lable image memory has been filled At that point the reader will stop saving additional images In this mode you will always have the first image captured because the saving process stops once memory has been filled Last Mode In this mode image storage continues after available memory limits are reached The oldest image in memory is overwritten so you will always have the most recent stored image D...

Страница 123: ... 3 captures Number of Symbols 1 Frame 1 No Read Frame 2 No Read Frame 3 Good Read Symbol 1 Read Cycle Result Good Read Stored Frame None Number of Symbols 1 Frame 1 No Read Frame 2 No Read Frame 3 No Read Read Cycle Result No Read Stored Frame Frame 3 Number of Symbols 2 Frame 1 No Read Frame 2 No Read Frame 3 Good Read Symbol 1 Read Cycle Result No Read Stored Frame Frame 2 ...

Страница 124: ...ser s Manual Z392 5 27 Read Cycle Decodes Before Output Good Decode s Needed Definition This value specifies the number of times a symbol needs to be read to qualify as a good read Serial Cmd K221 good decode s needed Default 1 Options 1 to 255 ...

Страница 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...

Страница 126: ...ed by the V430 series Symbologies by ESP 6 2 Symbologies Serial Commands 6 3 Data Matrix 6 4 Aztec 6 6 QR Code 6 7 Micro QR Code 6 8 Code 39 6 9 Code 128 EAN 128 6 12 BC412 6 15 Interleaved 2 of 5 6 16 Code 93 6 19 Codabar 6 20 UPC EAN 6 23 Pharmacode 6 27 Postal Symbologies 6 30 GS1 DataBar 6 35 PDF417 6 37 MicroPDF417 6 38 Composite 6 39 DotCode 6 40 ...

Страница 127: ...ser s Manual Z392 Symbologies by ESP Symbologies by ESP To change a setting double click the setting and use your cursor to scroll through the options Click the Parameters button and then the Symbologies tab To open nested options single click the ...

Страница 128: ...us separator character supplemental type format UPC E as UPC A Code 128 EAN 128 K474 status fixed symbol length status fixed symbol length EAN 128 status output format application record separator status application record separator character application record brackets application record padding Code 93 K475 status fixed symbol length status symbol length PDF417 K476 status unused fixed symbol le...

Страница 129: ...zed by the upper right corner module being light binary 0 instead of dark Definition When enabled will decode ECC 200 Data Matrix symbols Serial Cmd K479 ECC 200 status ECC 000 status ECC 050 status ECC 080 status ECC 100 status ECC 140 status ECC 120 status ECC 130 status Default Enabled Note This is the only symbol type enabled by default Options 0 Disabled 1 Enabled Definition When enabled will...

Страница 130: ...ult Disabled Options 0 Disabled 1 Enabled Definition When enabled will decode ECC 140 symbols Serial Cmd K479 ECC 200 status ECC 000 status ECC 050 status ECC 080 status ECC 100 status ECC 140 status ECC 120 status ECC 130 status Default Disabled Options 0 Disabled 1 Enabled Definition When enabled will decode ECC 120 symbols Serial Cmd K479 ECC 200 status ECC 000 status ECC 050 status ECC 080 sta...

Страница 131: ...uare grid with a square bull s eye pattern at the center Aztec can encode up to 3 832 numeric or 3 067 alphabetical characters or 1 914 bytes of data The level of Reed Solomon error correction used with Aztec is configurable from 5 to 95 of the total data region The recommended error correction level is 23 of symbol capacity plus codewords Serial Cmd K458 status Default Disabled Options 0 Disabled...

Страница 132: ...Up to 7 366 characters numeric data can be encoded using this symbol Therefore less space is required to encode the same amount of data in a QR Code symbol than in a conventional symbol lowering the cost of labelling Three Position Detection Patterns in the symbol make omnidirectional ultra fast reading possible QR Code has error protection capability Data can often be restored even if a part of t...

Страница 133: ... density than that provided by standard QR Code Some application examples are automotive inventory vehicle ID and mobile phone URL encodation Definition Micro QR Code is a 2D matrix symbology that comes in 4 different symbol sizes the largest capable of encoding 35 numeric characters Serial Cmd K459 status Default Enabled Options 0 Disabled 1 Enabled ...

Страница 134: ...ck character output status large intercharacter gap fixed symbol length status fixed symbol length full ASCII set Default Disabled Options 0 Disabled 1 Enabled Usage Check Character Output Status added to the symbol provides addi tional data security Definition When enabled the check character character is read and compared along with the symbol data When disabled symbol data is sent without the c...

Страница 135: ...l check the symbol length against the symbol length field If disabled any length will be considered valid Serial Cmd K470 status check character status check character output status large intercharacter gap fixed symbol length status fixed symbol length full ASCII set Default Disabled Options 0 Disabled 1 Enabled Usage Fixed Symbol Length helps prevent truncations and increases data integrity by e...

Страница 136: ...e one character it is less efficient Definition Standard Code 39 encodes 43 characters zero through nine capital A through capital Z minus symbol plus symbol forward slash space decimal point dollar sign and percent symbol When Full ASCII Set is enabled the reader can read the full ASCII character set from 0 to 255 Serial Cmd K470 status check character status check character output status large i...

Страница 137: ...the symbol length against the symbol length field If disabled any length will be considered a valid symbol Serial Cmd K474 status fixed symbol length status fixed symbol length EAN 128 status output format application record separator status application record separator character application record brackets application record padding Default Disabled Options 0 Disabled 1 Enabled Usage Fixed Symbol...

Страница 138: ...4 status fixed symbol length status fixed symbol length EAN 128 status output format application record separator status application record separator character application record brackets application record padding Default Disabled Options 0 Disabled 1 Enabled 2 Required Definition In Standard the reader will not apply special EAN output formatting options In Application the reader will apply the ...

Страница 139: ... decoded and EAN formatting applies this feature places bracket characters around the application identifiers in the formatted output Serial Cmd K474 status fixed symbol length status fixed symbol length EAN 128 status output format application record separator status application record separator character application record brackets application record padding Default Disabled Options 0 Disabled 1...

Страница 140: ...symbol length Default Disabled Options 0 Disabled 1 Enabled Usage Check Character Output added to the symbol provides additional security Definition When enabled the check character is read and compared along with the symbol data When disabled symbol data is sent without the check charac ter Serial Cmd K481 status check character output fixed symbol length status fixed symbol length Default Disabl...

Страница 141: ...nt You must set Symbol Length in order to decode I 2 5 symbols unless Range Mode is enabled Serial Cmd K472 status check character status check character output status symbol length 1 symbol length 2 guard bar status range mode status Default Enabled Options 0 Disabled 1 Enabled Usage This option is not typically used but it can be enabled for additional security in applications where the host req...

Страница 142: ...to be considered a valid symbol If Range Mode is enabled Symbol Length 1 and Symbol Length 2 form a range into which the length of the symbol must fall to be considered valid Usage Useful in applications where I 2 5 symbols of a specific length are required Definition The Symbol Length 2 field is one of two fields against which the decoded symbol is compared before accepting it as valid or rejecti...

Страница 143: ...de status Default Disabled Options 0 Disabled 1 Enabled Usage Useful in applications where I 2 5 symbols of a specific length are required Definition When Range Mode is disabled the reader checks the value of the symbol length against the values set in Symbol Length 1 and Symbol Length 2 If the symbol length does not match either of the preset values then it is rejected as invalid When Range Mode ...

Страница 144: ...K475 status fixed symbol length status symbol length Default Enabled Options 0 Disabled 1 Enabled Definition When disabled the reader will accept any Code 93 symbol provided is doesn t exceed the system s maximum capabilities When enabled the reader will reject any Code 93 symbol that doesn t match the fixed symbol length Serial Cmd K475 status fixed symbol length status symbol length Default Disa...

Страница 145: ...top characters are the same When enabled the reader will not decode Codabar symbols unless the start and stop characters are the same Serial Cmd K471 status start stop match start stop output large intercharacter gap fixed symbol length status symbol length check character type check character output Default Enabled Options 0 Disabled 1 Enabled Definition When disabled the start and stop character...

Страница 146: ...k character output Default Disabled Options 0 Disabled 1 Enabled Definition When disabled the reader will accept any Codabar symbol provided it doesn t exceed the system s maximum capabilities When enabled the reader will reject any Codabar symbol that doesn t match the fixed length Serial Cmd K471 status start stop match start stop output large intercharacter gap fixed symbol length status symbol...

Страница 147: ...mbol does not pass either calculation it will not be decoded Serial Cmd K471 status start stop match start stop output large intercharacter gap fixed symbol length status symbol length check character type check character output Default Disabled Options 0 Disabled 1 Mod 16 2 NW7 Mod 11 3 Mod 16 and NW7 Definition When this field is disabled and a check character calculation is enabled the reader w...

Страница 148: ...um character When enabled the reader will read UPC Version A and UPC Version E only Serial Cmd K473 UPC status EAN status supplementals status separator status separator character supplemental type format UPC E as UPC A Default Enabled Options 0 Disabled 1 Enabled Usage EAN is the European version of the UPC symbology and is used in European market applications Note UPC must be enabled for EAN to ...

Страница 149: ...ly Separator Status UPC EAN Usage Reads Supplementals typically used in publications and documentation Definition A supplemental is a 2 to 5 digit symbol appended to the main symbol When set to Enabled or Required the reader reads supplemental code data that has been appended to the standard UPC or EAN codes Serial Cmd K473 UPC status EAN status supplementals status separator status separator char...

Страница 150: ...cter is defined as a comma sending a K473 s command will return the current settings including the separator character comma which appears after the separator status comma Usage As required by the application Definition Allows the user to change the separator character from a comma to a new character Serial Cmd K473 UPC status EAN status supplementals status separator status separator character su...

Страница 151: ...AN status supplementals status separator status separator character supplemental type format UPC E as UPC A Default Both Options 0 Both 1 2 characters only 2 5 characters only Definition When disabled the reader will output the version E symbols in their encoded 6 character format When enabled the reader will format the symbol as either a 12 character UPC A symbol or an EAN 13 symbol depending on ...

Страница 152: ...tus direction fixed threshold value background color Default Disabled Options 0 Disabled 1 Enabled Definition When enabled the reader will check the symbol length against the symbol length field If disabled any length will be considered valid Serial Cmd K477 status fixed symbol length status fixed symbol length minimum number of bars bar width status direction fixed threshold value background colo...

Страница 153: ...77 status fixed symbol length status fixed symbol length minimum number of bars bar width status direction fixed threshold value back ground color Default Mixed Options 0 Mixed 1 All Narrow 2 All Wide 3 Fixed Threshold Definition Specifies the direction in which a symbol can be read Serial Cmd K477 status fixed symbol length status fixed symbol length minimum number of bars bar width status direct...

Страница 154: ...sed when the color of bars is reversed Sets the background color that a Pharmacode symbol must have to be considered valid Serial Cmd K477 status fixed symbol length status fixed symbol length minimum number of bars bar width status direction fixed threshold value background color Default White Options 0 Black 1 White ...

Страница 155: ... element value of 4 to be decoded reliably by the reader The reader must be configured to specific read range field of view and camera parameters before decoding Postal Symbologies For optimal decode results position the symbol as close to the center of the reader s field of view as possible Position the postal symbol in the center of the reader s field of view ...

Страница 156: ...uditing certified mail registered mail metered mail and point of sale POS applications Definition Determines the postal symbology that will be decoded by the reader Serial Cmd K460 postal symbology type POSTNET status PLANET status USPS4CB status Default Disabled Options 0 Disabled 1 U S Post POSTNET PLANET USPS4CB 2 Australia Post 3 Japan Post 4 Royal Mail 5 KIX 6 UPU ...

Страница 157: ...K460 1 0 POSTNET symbols will not be decoded by the reader See POSTNET Status PLANET Status and GS1 DataBar for more detail about U S Post symbologies Australia Post When Australia Post is enabled K460 2 the reader will only decode Australia Post symbols Japan Post When Japan Post is enabled K460 3 the reader will only decode Japan Post symbols Royal Mail When Royal Mail is enabled K460 4 the read...

Страница 158: ... type POSTNET status PLANET status USPS4CB status Default Enabled Options 0 Disabled 1 Enabled Usage PLANET Postal Alphanumeric Encoding Technique is a symbology used by the United States Postal Service to track and identify items during delivery Each PLANET symbol is either 12 or 14 digits long and encodes data in half height and full height bars making PLANET a 2 state symbology The symbol alway...

Страница 159: ...encoded in four types of bars states each of which is identified by a name and a value This type of postal symbol is known as 4 state Each bar has a tracker or middle section to which an ascender top section or descender bottom section may be added The 4 state format allows the symbol to contain more information and makes it easier to decode 4 state symbols can also be printed easily in a variety ...

Страница 160: ...h Default Enabled Options 0 Disabled 1 Enabled Definition When enabled the reader will check the symbol length against the sym bol length field minus the embedded check character If disabled any length would be considered valid Serial Cmd K484 status fixed symbol length status fixed symbol length Default Disabled Options 0 Disabled 1 Enabled Usage Fixed Symbol Length helps prevent truncations and ...

Страница 161: ...Cmd K483 status Default Enabled Options 0 Disabled 1 Enabled Usage Used in the grocery retail and prescription drug industries where 14 digit EAN item identification may be needed Definition DataBar 14 is a fixed symbol length symbology that encodes 14 digits including a 1 digit indicator DataBar 14 is 96 modules wide It can be stacked in two rows it can read omnidirectionally if printed in full h...

Страница 162: ... will be read at several stations along the way without reference to a database Definition A two dimensional multi row 3 to 90 continuous variable length symbology that has high data capacity for storing up to 2 700 numeric characters 1 800 printable ASCII characters or 1 100 binary characters per symbol Each symbol character consists of 4 bars and 4 spaces in a 17 module structure Serial Cmd K476...

Страница 163: ...ymbol Serial Cmd K485 status unused fixed symbol length status fixed symbol length Default Enabled Options 0 Disabled 1 Enabled Serial Cmd K485 status unused fixed symbol length status fixed symbol length Default Disabled Options 0 Disabled 1 Enabled Usage Used to increase data integrity by ensuring that only one symbol length will be accepted Definition When enabled the MicroPDF417 symbol must co...

Страница 164: ...The Separator Character will be the same as the character defined in the Multisymbol Separator field of the K222 command Usage Allows reading by both linear and 2D readers Definition Combines 2D and linear width modulated symbology on the same symbol where different messages can be read by each reader type Serial Cmd K453 mode separator status separator Default Disabled Options 0 Disabled 1 Enable...

Страница 165: ...No Rotation The reader will decode horizontal and vertical symbols approximately 3 degrees Low Rotation The reader will decode approximately 10 degrees from the horizontal or vertical symbols It is slightly slower than the No Rotation option OmniDirectional The reader will support 360 degree reading Omnidirectional is significantly slower than the other two options Serial Cmd K497 status rotation ...

Страница 166: ... 7 27 ISO IEC 15415 Symbol Quality Output 1 7 30 ISO IEC 15416 Symbol Quality Output 1 7 37 ISO IEC 29158 Symbol Quality Output 1 7 45 Diagnostics Output 1 7 50 Configurable Output 2 7 51 Trend Analysis Output 2 7 51 ISO IEC 16022 Symbol Quality Output 2 7 51 ISO IEC 15415 Symbol Quality Output 2 7 52 ISO IEC 15416 Symbol Quality Output 2 7 52 ISO IEC 29158 Symbol Quality Output 2 7 52 Diagnostics...

Страница 167: ... I O Parameters by ESP I O Parameters by ESP To open nested options single click the and it will become a as shown above To change a setting double click the setting and use your cursor to scroll through the options Click the Parameters button and then the I O tab ...

Страница 168: ...t on power on load configuration database save for power on Setup Button Modes K771 button option 1 button option 2 button option 3 button option 4 Trend Analysis Output 1 K780 trend analysis mode number of triggers number to output on decodes per trigger Trend Analysis Output 2 K781 trend analysis mode number of triggers number to output on decodes per trigger Trend Analysis Output 3 K782 trend a...

Страница 169: ...hreshold ISO IEC 15416 Symbol Quality Output 2 K881 Output on Overall Grade Overall Grade Threshold Edge Determination Edge Determination Threshold Decode Decode Threshold Contrast Contrast Threshold Min Reflectance Min Reflectance Threshold Min Edge Contrast Min Edge Contrast Threshold Modulation Modulation Threshold Defects Defects Threshold Decodability Decodability Threshold Quiet Zone Quiet Z...

Страница 170: ...ons 0 Disabled 1 Match 2 Mismatch 3 Any Good Read 4 Only If All Good Reads Usage It is useful when an application only needs to use the discrete outputs and can allow the reader to do the decision making When Disabled the host does not need the symbol data and the communication lines are used only for setup and status checks Definition When set to Disabled the reader will not transmit any data tha...

Страница 171: ...racking applications in which each object is uniquely identified Definition With Any Good Read enabled the reader outputs symbol data for any qualified symbol in the read cycle regardless of Matchcode Type setting No Read is output if no symbols are qualified Definition With Only If All Good Reads enabled the reader outputs symbol data only when all symbols in the read cycle are qualified No Read ...

Страница 172: ...Usage As Soon As Possible is useful in applications in which symbol data needs to be moved quickly to the host typically when the host is making decisions based on symbol data Definition Enabling As Soon As Possible causes symbol data to be sent to the host immediately after a symbol has been successfully decoded Usage End of Read Cycle is useful in timing based systems in which the host is not re...

Страница 173: ...When set to Disabled the symbol data output does not contain symbology information Enabled When set to Enabled the symbol data output contains a three character symbology identifier sequence Serial Cmd K705 symbol data output status when to output symbology identifier status Default Disabled Options 0 Disabled 1 Enabled ...

Страница 174: ...be set to any ASCII character Usage Used in applications where the host needs serial verification that a symbol has not been read and especially useful in new print verification Definition When enabled and if no symbol has been decoded before timeout or the end of the read cycle the No Read message will be transmitted to the host Serial Cmd K714 No Read message status No Read message Default Enabl...

Страница 175: ...ful in evaluating actual read cycle timing results especially when initially setting up an application to determine maximum line speed obtainable based on spacing between symbols Definition When enabled the duration of the read cycle in milliseconds is appended to the symbol data The read duration is the time from the beginning of the read cycle until data is output Serial Cmd K706 status separato...

Страница 176: ...w of five status LEDs on the side of the reader Green Flash Mode Disabled Green flash LEDs are disabled Good Read Green flash LEDs will flash when a good read condition is met or when Matchcode is enabled and a match occurs Usage Used as a visual verification that a good read has occurred Definition An array of green LEDs in the front of the reader can be programmed to flash in response to user de...

Страница 177: ... Presentation Mode is selected but the reader is not in Continuous Read the Green Flash will not occur To use Static Presentation 1 Enable Continuous Read 2 Select the number of symbols 3 Enable Static Presentation in Green Flash Mode 4 Select the read time in Green Flash Duration Match The green LEDs will flash when a match condition is met If multisymbol is enabled then green flash LEDs will ill...

Страница 178: ...Cycle The target pattern will remain OFF except during the read cycle If the operational command overrides this setting the target pattern will remain on at all times Always ON The target pattern is always ON Usage Assists users in positioning and locating symbols in the center of the reader s field of view Definition The user can control when the targeting system is ON or OFF and can save this co...

Страница 179: ...ides visual verification that a good read has occurred Definition When a good read occurs the green LEDs will illuminate and stay on for the time set in the Green Flash Duration value Serial Cmd K750 green flash mode target pattern status green flash duration Default 25 250ms Options 0 to 65535 in 10 ms increments ...

Страница 180: ...Standard Mode the STATUS LED indicates read cycle status and the GOOD READ LED illuminates upon a good read at the end of a read cycle In a read rate test these LEDs represent the percentage of good reads per images captured ISO IEC 16022 Grade Usage Useful as a visible indicator of read rates and symbol quality Definition Determines the mode in which the status LEDs operate Serial Cmd K737 LED mo...

Страница 181: ...rom the host is echoed back to the host with the resultant settings Function If a command with multiple fields is processed some of the fields may have been processed properly while others were not The changes will appear in the string echoed back so that the user will know which fields did or did not change Serial Cmd K701 serial command echo status unused control hex output Default Disabled Opti...

Страница 182: ...are inactive Parameter Switch The parameter switch toggles between custom defaults and power on settings The condition is the same as that achieved by sending the Arc and Arp commands consecutively Definition Serves as a master switch to enable disable the Setup button status Serial Cmd K770 global status default on power on load Configuration Database save for power on Default Enabled Options 0 D...

Страница 183: ... Allows the user to load the Configuration Database with calibration results When the user performs a calibration using the Setup button all the data base entries are moved down one index and the results of the calibration are saved to index 1 The results will be saved as current settings as well Serial Cmd K770 global status default on power on load Configuration Database save for power on Defaul...

Страница 184: ... press the button the reader will sequence through each button position If you release the button after the button position but before the next button option starts the reader will execute the action programmed for that button position The status LEDs and the green flash will also illuminate to signal the current position All button positions have the same configurable options Also note that a qui...

Страница 185: ...ave the target system on before another operation such as calibration or read rate is performed ensure that the target system mode is assigned a lower position so that it will be activated first Bar Code Configuration Enables bar code configuration mode whenever the associated button position is selected When enabled the imager can accept configuration commands from symbols To disable quickly pres...

Страница 186: ... for Match Mismatch Activates a discrete output whenever the symbol data does not match that of the master symbol No Read Activates a discrete output whenever the symbol data is not decoded before the end of the read cycle Usage This option provides discrete signalling to host software to control external devices such as PLCs and relays It is useful for routing sorting and to prevent mis packaging...

Страница 187: ... met depending on the trend analysis option enabled Usage Typically used when a discrete indication is needed to flag a symbol quality condition Definition Activates discrete output when a symbol quality condition is met depending on the symbol quality option enabled Usage Typically used when a discrete indication of a diagnostic condition is needed Definition Activates discrete output when a diag...

Страница 188: ...od read occurs Latch Mode 3 Unlatch Re enter Read Cycle The programmable output is active when the Output On condition has been met and is held active until a new read cycle begins Note All of the Output On modes are inhibited when any Output on Warning is active for Output 1 Definition Sets the active electrical state of the discrete output Serial Cmd K810 output on output state pulse width outpu...

Страница 189: ...t down for one condition but wants to monitor quality and read conditions Definition Applies Trend Analysis settings to Output 1 With Trend Analysis the user can track the occurrences and frequency of mismatches No Reads and the number of reads per trigger and output the results to any of three outputs Example Trend Analysis Mode No Read Trigger Evaluation Period 25 triggers read cycles Number to ...

Страница 190: ...ntered for Number to Output On within the trigger window selected in Number of Triggers Decodes per Trigger Output will be activated when the number of decodes equals the value entered for Number to Output On within the trigger window selected in Number of Triggers Definition Sets the trend condition Mismatch No Read or Decodes per Trigger that will activate the output Serial Cmd K780 trend analys...

Страница 191: ... configured by Trend Analysis Mode to occur within the trigger evaluation period before activating the associated output Serial Cmd K780 trend analysis mode trigger evaluation period number to output on decodes per trigger threshold Default 0 Options 0 to 255 Definition The appropriate output will be activated if at the end of the read cycle the symbol decode count is below this setting Note To ac...

Страница 192: ...ast Threshold is met Serial Cmd K800 output on symbol contrast symbol contrast threshold output on print growth print growth threshold output on axial non uniformity axial non uniformity threshold output on UEC UEC threshold Default Disabled Options 0 Disabled 1 Enabled Usage Lets the user know if symbol quality is less than acceptable Definition If enabled toggles Output 1 to an active state when...

Страница 193: ...nabled Usage Lets the user know if symbol quality is less than acceptable Definition If enabled toggles Output 1 to an active state when UEC Threshold is met Serial Cmd K800 output on symbol contrast symbol contrast threshold output on print growth print growth threshold output on axial non uniformity axial non uniformity threshold output on UEC UEC threshold Default Disabled Options 0 Disabled 1 ...

Страница 194: ... user set the acceptable level of symbol quality Definition Conforms to ISO IEC 16022 symbol quality grading A B C D Serial Cmd K800 output on symbol contrast symbol contrast threshold output on print growth print growth threshold output on axial non uniformity axial non uniformity threshold output on UEC UEC threshold Default Grade C Options 0 Grade A 1 Grade B 2 Grade C 3 Grade D Usage Lets the ...

Страница 195: ...ast threshold modulation modulation threshold reflectance margin reflectance margin threshold fixed pattern damage fixed pattern damage threshold axial non uniformity axial non uniformity threshold grid non uniformity grid non uniformity threshold unused ECC unused ECC threshold Default Disabled Options 0 Disabled 1 Enabled Usage Sets the threshold for driving the output Definition Conforms to ISO...

Страница 196: ...g A B C D Serial Cmd K870 output on overall grade overall grade threshold symbol contrast symbol contrast threshold modulation modulation threshold reflectance margin reflectance margin threshold fixed pattern damage fixed pattern damage threshold axial non uniformity axial non uniformity threshold grid non uniformity grid non uniformity threshold unused ECC unused ECC threshold Default Grade B Op...

Страница 197: ...iformity threshold grid non uniformity grid non uniformity threshold unused ECC unused ECC threshold Default Grade B Options 0 Grade D 1 Grade C 2 Grade B 3 Grade A Usage Lets the user know if symbol quality is less than acceptable Definition If enabled drives Output if grade is under Reflectance Margin Threshold Serial Cmd K870 output on overall grade overall grade threshold symbol contrast symbo...

Страница 198: ... enabled drives Output if grade is under Fixed Pattern Damage Thresh old Serial Cmd K870 output on overall grade overall grade threshold symbol contrast symbol contrast threshold modulation modulation threshold reflectance margin reflectance margin threshold fixed pattern damage fixed pattern damage threshold axial non uniformity axial non uniformity threshold grid non uniformity grid non uniformi...

Страница 199: ...formity threshold grid non uniformity grid non uniformity threshold unused ECC unused ECC threshold Default Disabled Options 0 Disabled 1 Enabled Usage Sets the threshold for driving the output Definition Conforms to ISO IEC 15415 symbol quality grading A B C D Serial Cmd K870 output on overall grade overall grade threshold symbol contrast symbol contrast threshold modulation modulation threshold ...

Страница 200: ...modulation threshold reflectance margin reflectance margin threshold fixed pattern damage fixed pattern damage threshold axial non uniformity axial non uniformity threshold grid non uniformity grid non uniformity threshold unused ECC unused ECC threshold Default Grade B Options 0 Grade D 1 Grade C 2 Grade B 3 Grade A Usage Lets the user know if symbol quality is less than acceptable Definition If ...

Страница 201: ...ymbol contrast symbol contrast threshold modulation modulation threshold reflectance margin reflectance margin threshold fixed pattern damage fixed pattern damage threshold axial non uniformity axial non uniformity threshold grid non uniformity grid non uniformity threshold unused ECC unused ECC threshold Default Grade B Options 0 Grade D 1 Grade C 2 Grade B 3 Grade A ...

Страница 202: ...hold edge determina tion edge determination threshold decode decode threshold contrast contrast threshold min reflectance min reflectance threshold min edge contrast min edge contrast threshold modulation modulation threshold defects defects threshold decodability decodability threshold quiet Zone quiet zone threshold Default Disabled Options 0 Disabled 1 Enabled Usage Sets the threshold for drivi...

Страница 203: ...n threshold defects defects threshold decodability decodability threshold quiet Zone quiet zone threshold Default Disabled Options 0 Disabled 1 Enabled Usage Sets the threshold for driving the output Definition Conforms to ISO IEC 15416 symbol quality grading A B C D Serial Cmd K880 output on overall grade overall grade threshold edge determina tion edge determination threshold decode decode thres...

Страница 204: ...tion edge determination threshold decode decode threshold contrast contrast threshold min reflectance min reflectance threshold min edge contrast min edge contrast threshold modulation modulation threshold defects defects threshold decodability decodability threshold quiet Zone quiet zone threshold Default Grade B Options 0 Grade D 1 Grade C 2 Grade B 3 Grade A Usage Lets the user know if symbol q...

Страница 205: ...f enabled drives Output if grade is under Min Reflectance Threshold Serial Cmd K880 output on overall grade overall grade threshold edge determina tion edge determination threshold decode decode threshold contrast contrast threshold min reflectance min reflectance threshold min edge contrast min edge contrast threshold modulation modulation threshold defects defects threshold decodability decodabi...

Страница 206: ...fects threshold decodability decodability threshold quiet Zone quiet zone threshold Default Disabled Options 0 Disabled 1 Enabled Usage Sets the threshold for driving the output Definition Conforms to ISO IEC 15416 symbol quality grading A B C D Serial Cmd K880 output on overall grade overall grade threshold edge determina tion edge determination threshold decode decode threshold contrast contrast...

Страница 207: ...code decode threshold contrast contrast threshold min reflectance min reflectance threshold min edge contrast min edge contrast threshold modulation modulation threshold defects defects threshold decodability decodability threshold quiet Zone quiet zone threshold Default Grade B Options 0 Grade D 1 Grade C 2 Grade B 3 Grade A Usage Lets the user know if symbol quality is less than acceptable Defin...

Страница 208: ... overall grade threshold edge determina tion edge determination threshold decode decode threshold contrast contrast threshold min reflectance min reflectance threshold min edge contrast min edge contrast threshold modulation modulation threshold defects defects threshold decodability decodability threshold quiet Zone quiet zone threshold Default Disabled Options 0 Disabled 1 Enabled Usage Sets the...

Страница 209: ... modulation modulation threshold defects defects threshold decodability decodability threshold quiet Zone quiet zone threshold Default Disabled Options 0 Disabled 1 Enabled Usage Sets the threshold for driving the output Definition Conforms to ISO IEC 15416 symbol quality grading A B C D Serial Cmd K880 output on overall grade overall grade threshold edge determina tion edge determination threshol...

Страница 210: ...old cell contrast cell contrast threshold cell modulation cell modulation threshold fixed pattern damage fixed pattern damage threshold axial non uniformity axial non uniformity threshold grid non uniformity grid non uniformity threshold unused ECC unused ECC threshold Default Disabled Options 0 Disabled 1 Enabled Usage Sets the threshold for driving the output Definition Conforms to ISO IEC 29158...

Страница 211: ...mbol quality grading A B C D Serial Cmd K890 output on overall grade overall grade threshold cell contrast cell contrast threshold cell modulation cell modulation threshold fixed pat tern damage fixed pattern damage threshold axial non uniformity axial non uniformity threshold grid non uniformity grid non uniformity threshold unused ECC unused ECC threshold Default Grade B Options 0 Grade D 1 Grad...

Страница 212: ...Fixed Pattern Damage Thresh old Serial Cmd K890 output on overall grade overall grade threshold cell contrast cell contrast threshold cell modulation cell modulation threshold fixed pat tern damage fixed pattern damage threshold axial non uniformity axial non uniformity threshold grid non uniformity grid non uniformity threshold unused ECC unused ECC threshold Default Disabled Options 0 Disabled 1...

Страница 213: ...tput on overall grade overall grade threshold cell contrast cell Definition Conforms to ISO IEC 29158 symbol quality grading A B C D contrast threshold cell modulation cell modulation threshold fixed pattern damage fixed pattern damage threshold axial non uniformity axial non uniformity threshold grid non uniformity grid non uniformity threshold unused ECC unused ECC threshold Default Grade B Opti...

Страница 214: ...d drives Output if grade is under Unused ECC Threshold Serial Cmd K890 output on overall grade overall grade threshold cell contrast cell contrast threshold cell modulation cell modulation threshold fixed pattern damage fixed pattern damage threshold axial non uniformity axial non uniformity threshold grid non uniformity grid non uniformity threshold unused ECC unused ECC threshold Default Disable...

Страница 215: ...tput will remain active as long as one of the diagnostic warning conditions is met The output will become inactive once it detects that there are no diagnostic warning conditions Serial Cmd K790 unused 1 service unit Default 0 Options 0 Disabled Definition Allows the user to set up the output to toggle to active when the service timer has expired This condition will only be held for one service ti...

Страница 216: ...ction ISO IEC 16022 Symbol Quality Output 2 Note Output On under Output 2 Parameters must be set to Symbol Quality for this output to function Serial Cmd K811 output on output state pulse width output mode Serial Cmd K781 trend analysis mode trigger evaluation period number to output on Serial Cmd K801 output on symbol contrast symbol contrast threshold output on print growth print growth threshol...

Страница 217: ...ld fixed pattern damage fixed pattern damage threshold axial non uniformity axial non uniformity threshold grid non unifor mity grid non uniformity threshold unused ECC unused ECC threshold Serial Cmd K881 output on overall grade overall grade threshold edge determination edge determination threshold decode decode threshold contrast contrast threshold min reflectance min reflectance threshold min ...

Страница 218: ...st be set to Trend Analysis for this output to function ISO IEC 16022 Symbol Quality Output 3 Note Output On under Output 3 Parameters must be set to Symbol Quality for this output to function Serial Cmd K791 unused 1 service unit Serial Cmd K812 output on output state pulse width output mode Serial Cmd K782 trend analysis mode trigger evaluation period number to output on Serial Cmd K802 output o...

Страница 219: ...ld fixed pattern damage fixed pattern damage threshold axial non uniformity axial non uniformity threshold grid non unifor mity grid non uniformity threshold unused ECC unused ECC threshold Serial Cmd K882 output on overall grade overall grade threshold edge determination edge determination threshold decode decode threshold contrast contrast threshold min reflectance min reflectance threshold min ...

Страница 220: ...e Reader V430 series User s Manual Z392 7 55 I O Parameters Diagnostics Output 3 Note Output On under Output 3 Parameters must be set to Diagnostic Warning for this output to function Serial Cmd K792 unused 1 service unit ...

Страница 221: ...s Power On Saves uses a 16 bit counter that increments each time an reader setting is saved for power on with a Z command Power On Flash Saves Power On Flash Saves uses a 16 bit counter that increments each time an reader setting is saved to the customer parameter section of flash memory with a Zc command Serial Cmd K406 power on resets power on saves power on flash saves Serial Cmd K406 power on ...

Страница 222: ...mmand Hours Hours uses a 16 bit counter that increments every 60 minutes Minutes Minutes uses a 16 bit counter that increments every 60 seconds Note Time counts are reset at power on but not with an A or Z command Serial Cmd K407 hours minutes Default 16 bit counter 0 to 65535 Serial Cmd K407 hours minutes Default 16 bit counter 0 to 60 ...

Страница 223: ...time since last reset Service timer increments can be set in seconds or minutes Service Message Threshold Resolution Serial Cmd K409 status service message threshold resolution Default 0 Options 0 Disabled 1 Enabled Serial Cmd K409 status service message threshold resolution Default SERVICE Options An ASCII string between 1 and 10 characters Serial Cmd K409 status service message threshold resolut...

Страница 224: ... Name allows you to enter any string of ASCII characters to help you identify your reader The user assigned name is saved at power on and custom defaults and is stored as a sticky parameter so it cannot be defaulted without a Zrdall or K412d command Serial Cmd K412 user assigned name Options ASCII string up to 19 characters ...

Страница 225: ...etween the end of the already for matted data and the F that precedes the frame number Output Coordinates Disabled When Output Coordinates is set to Disabled the coordinates are not output as part of the symbol data Enabled When Output Coordinates is set to Enabled the four sets of object coordinates for the first successfully decoded symbol are attached to the symbol data output in the following ...

Страница 226: ...n Database For example if the separator is an underscore character and the second database entry reads a symbol encoded with data capture during the read cycle the symbol data output will be data capture_DB02 If the database is not active no identifiers will be attached to output Separator Usage Useful in keeping track of which database entries read which symbols Serial Cmd K759 status separator D...

Страница 227: ...decodes per trigger status Default Options Any ASCII character Definition When this feature is enabled the reader enters a state where it processes frames as configured until the end of a read cycle with or without a successful symbol decode When the read cycle ends the reader outputs any decoded symbol data along with the decodes per trigger count Serial Cmd K704 separator decodes per trigger sta...

Страница 228: ...enabled Serial Cmd status transfer port image mode image format image quality object info enable grade enable Default Disabled Options 0 Disabled 1 Enabled Definition Selects the communication port that will be used to transfer image files Serial Cmd K757 status transfer port image mode image format JPEG quality object info enable grade enable Default RS 232 Options 0 RS 232 3 Ethernet TCP Port 1 ...

Страница 229: ...ion even when manipulated and saved multiple times When Lossless is enabled the JPEG Quality setting has no effect Compressed Outputs the image in JPEG format Image quality is determined by the JPEG Quality setting Image Quality Definition Selects the format of the image output file Serial Cmd K757 status transfer port image mode image format image quality object info enable grade enable Default C...

Страница 230: ...also included Serial Cmd K757 status transfer port image mode image format image quality object info enable grade enable Default Disabled Options 0 Disabled 1 Enabled Definition Symbol quality information will be output in the form of an abbreviated identifier for each read cycle Serial Cmd K757 status transfer port image mode image format image quality object info enable grade enable Default Disa...

Страница 231: ...e quality image scale file save options Default Disabled Options 0 Disabled 1 Enabled Definition Stored Image Type defines what kind of image you want to log in a read cycle Serial Cmd K763 image storage status stored image type image storage image file format image quality image scale file save options Default No Read Options 1 Good Read 2 No Read 3 Good Read No Read 4 Match 8 Mismatch 12 Match M...

Страница 232: ...ial Cmd K763 image storage status stored image type image storage image file format image quality image scale file save options Default 90 Options 1 to 100 Definition Image Scale defines the size you want the image to be Serial Cmd K763 image storage status stored image type image storage image file format image quality image scale file save options Default Full Options 0 Full 1 1 4th 2 1 8th Defi...

Страница 233: ...et count followed by its read cycle i d followed by its image i d followed by its stored image type defined in K763 as follows last 6 digits of device s MAC Address _ system total reset count _ read cycle id _ image id _ save image type png jpg last 6 digits of device s MAC Address _ system total reset count _ read cycle id _ image id _readreport xml Serial Cmd K764 image storage location FTP host...

Страница 234: ...ed The read cycle may be delayed due to image saving since each transfer will need to be finished before the end of the read cycle SOR Start of Read Cycle EOR End of Read Cycle Definition Transfer Optimization defines how the image is going to be stored in triggered captured modes Serial Cmd K764 image storage location FTP host info transfer optimization RAM drive size in MB save image until actio...

Страница 235: ...o transfer optimization RAM drive size in MB save image until action at image storage limit Default 20 Options 1 to 50 Definition This defines how long the image will be stored in the system when the Image Storage Location is RAM If set to New Read Cycle the saved image will be erased upon entering the next read cycle If set to System Reset the saved image will be erased upon the next system reset...

Страница 236: ...y ESP 8 2 Symbol Quality Serial Commands 8 3 Overview of Symbol Quality 8 4 Symbol Quality Separator Output Mode 8 5 ISO IEC 16022 Symbol Quality Output 8 7 ISO IEC 16022 Symbol Quality Output by ESP 8 9 Microscan Symbol Quality Output 8 13 Microscan Symbol Quality Output by ESP 8 16 ISO IEC 15415 Symbol Quality Output 8 17 ISO IEC 15416 Symbol Quality Output 8 22 ISO IEC 29158 Symbol Quality Outp...

Страница 237: ...s Manual Z392 Symbol Quality by ESP Symbol Quality by ESP To change a setting double click the setting and use your cursor to scroll through the options To open nested options single click the Click the Parameters button and then the Symbol Quality tab ...

Страница 238: ...ate time decode time pixels per element ECC level matrix size quiet zone symbol angle ISO IEC 15415 Symbol Quality Output K725 aperture overall contrast modulation reflectance margin fixed pattern damage axial nonuniformity grid nonuniformity unused ECC ISO IEC 15416 Symbol Quality Output K726 aperture overall edge determination decode contrast minimum reflectance minimum edge contrast modulation ...

Страница 239: ...ty parameters are separated into ISO IEC 16022 Symbol Quality Output Microscan Symbol Quality Output ISO IEC 15415 Symbol Quality Output ISO IEC 15416 Symbol Quality Output and ISO IEC 29158 Symbol Quality Output Total Read Time Symbol Quality Separator and Output Mode are common parameters The enabled Symbol Quality parameters are appended to symbol data output 0123456789abcdefghijklmnopqrstuv A ...

Страница 240: ...t ISO IEC 29158 Symbol Quality Output and Microscan Symbol Quality Output Symbol Quality Separator Symbol Quality Separator by ESP Definition Inserts a separator between each enabled field of the symbol quality output Serial Cmd K708 symbol quality separator output mode Default SP space character Options Any ASCII character When you double click on the default separator SP the Symbol Quality Separ...

Страница 241: ...ymbol quality parameters Grade If in Grade Mode a grade A B C D F is appended to the symbol data Value If in Value Mode the calculated value for the given parameter is appended to the symbol data Score If in Score Mode a percentage of passing lines for that parameter is appended to the symbol data Definition Output Mode specifies how the output parameters if enabled are format ted Serial Cmd K708 ...

Страница 242: ... F 0 0 if SC 20 If enabled the symbol contrast is appended to the symbol data according to the ISO IEC 16022 Symbol Quality Output Mode setting Serial Cmd K709 symbol contrast print growth axial non uniformity UEC Default Disabled Options 0 Disabled 1 Enabled Definition The extent to which dark or light markings appropriately fill or exceed their module boundaries These values are determined by co...

Страница 243: ...f AN 12 If enabled the axial non uniformity is appended to the symbol data according the ISO IEC 16022 Symbol Quality Output Mode setting Serial Cmd K709 symbol contrast print growth axial non uniformity UEC Default Disabled Options 0 Disabled 1 Enabled Definition The correction capacity of Reed Solomon decoding is expressed in the equation e 2d d p where e is the number of erasures d is the numbe...

Страница 244: ...tree control Once you have set these Data Matrix evaluation parameters go to the Preferences Tab and set your Data Matrix Grading Report output preferences After your output preferences are set click the Data Matrix Grading button There will be a wait of a few seconds and then the evaluation results will appear in the Symbol Quality view in a format similar to the one shown below If you want to vi...

Страница 245: ...g reports To save the report as a PDF file an HTML file a CSV file or an RTF file click the Save Report button Reports appear in the viewing area underneath the Data Matrix Grading and Save Report buttons The reader s field of view is shown here When grading is completed the initial report is also shown in this viewing area The Symbol Quality interface is divided into three sections Report Locate ...

Страница 246: ...e tab allows the user to determine the position of the symbol within the reader s field of view and to optimize the reader s camera settings for symbol quality evaluation Click the Calibrate button to optimize camera settings Click the Locate button to display the symbol in the reader s field of view ...

Страница 247: ...se a file path click Store Report without file path prompt Returns all settings to default Click the Include Image check box to output the captured symbol image with your saved report as a Bitmap or JPEG image file This information is appended at the bottom of the report Returns all settings to most recent Choose the default report type to be generated when you click Save Report on the Report tab ...

Страница 248: ...capture time locate time decode time pixels per element ECC level matrix size quiet zone symbol angle Default Disabled Options 0 Disabled 1 Enabled Definition Capture time in milliseconds is a fixed overhead that includes the time of capture and transfer of the image When enabled the capture time is appended to the symbol data Serial Cmd K710 percent cell damage total read time capture time locate...

Страница 249: ...appended to the symbol data Serial Cmd K710 percent cell damage total read time capture time locate time decode time pixels per element ECC level matrix size quiet zone symbol angle Default Disabled Options 0 Disabled 1 Enabled Definition Outputs the Data Matrix ECC level When enabled the ECC level is appended to the symbol data Serial Cmd K710 percent cell damage total read time capture time loca...

Страница 250: ... locate time decode time pixels per element ECC level matrix size quiet zone symbol angle Default Disabled Options 0 Disabled 1 Enabled Definition When this feature is enabled the symbol orientation is appended to data output as a degree value representing the angle of the Data Matrix symbol s L shaped finder pattern relative to the reader Serial Cmd K710 percent cell damage total read time captur...

Страница 251: ...te using the Symbol Quality tree control Once you have set these Data Matrix evaluation parameters go to the Preferences Tab and set your Data Matrix Grading Report output preferences After your output preferences are set click the Data Matrix Grading button There will be a wait of a few seconds and then the evaluation results will appear in the Symbol Quality view in a format similar to the one s...

Страница 252: ...using a 10 mil aperture you would configure the aperture to 67 10 15 0 67 Serial Cmd K725 aperture overall contrast modulation reflectance margin fixed pattern damage axial non uniformity grid non uniformity unused ECC Default 80 Options Any number between 0 to 100 Definition Overall is calculated in accordance with the ISO 15415 specification The overall grade is the lowest individual parameter g...

Страница 253: ...abled 1 Enabled Definition Modulation is calculated in accordance with the ISO 15415 specifica tion The Modulation grading is defined as follows A 4 0 if MOD 0 50 B 3 0 if MOD 0 40 C 2 0 if MOD 0 30 D 1 0 if MOD 0 20 F 0 0 if MOD 0 20 When enabled the Modulation is attached to the symbol output data as a value Serial Cmd K725 aperture overall contrast modulation reflectance margin fixed pattern da...

Страница 254: ...non uniformity grid non uniformity unused ECC Default Disabled Options 0 Disabled 1 Enabled Definition Axial Non Uniformity is calculated in accordance with the ISO 15415 specification The Axial Non Uniformity grading is defined as follows A 4 0 if AN 0 06 B 3 0 if AN 0 08 C 2 0 if AN 0 10 D 1 0 if AN 0 12 F 0 0 if AN 0 12 When enabled the Axial Non Uniformity is attached to the symbol out put dat...

Страница 255: ...25 aperture overall contrast modulation reflectance margin fixed pattern damage axial non uniformity grid non uniformity unused ECC Default Disabled Options 0 Disabled 1 Enabled Definition Unused ECC is calculated in accordance with the ISO 15415 specifica tion The Unused ECC grading is defined as follows A 4 0 if UEC 062 B 3 0 if UEC 0 50 C 2 0 if UEC 0 37 D 1 0 if UEC 0 25 F 0 0 if UEC 0 25 When...

Страница 256: ...430 series User s Manual Z392 8 21 Symbol Quality Grading Report VAL3 Responds with a text report that summarized the grading of ISO IEC15415 This command will return the evaluation results in a format similar to the one shown below ...

Страница 257: ...igure the aperture to 46 6 13 0 46 Serial Cmd K726 aperture overall edge determination decode contrast mini mum reflectance minimum edge contrast modulation defects decod ability quiet zone Default 40 Options Any number between 0 to 100 Definition Overall is calculated in accordance with the ISO 15416 specification The overall grade is the average of the individual scan grades applied to the symbo...

Страница 258: ...ica tion The parameter grade and value provided for output is an average value for each measured scan over the entire symbol When enabled the Decode is attached to the symbol output data as a value Serial Cmd K726 aperture overall edge determination decode contrast mini mum reflectance minimum edge contrast modulation defects decod ability quiet zone Default Disabled Options 0 Disabled 1 Enabled D...

Страница 259: ...d for each scan and provided for the overall grade calculation in accordance with the ISO 15416 specification The parameter grade and value pro vided for output is an average value for each measured scan over the entire symbol When enabled the Minimum Edge Contrast is attached to the symbol output data as a value Serial Cmd K726 aperture overall edge determination decode contrast mini mum reflecta...

Страница 260: ...fi cation The parameter grade and value provided for output is an aver age value for each measured scan over the entire symbol When enabled the Decodability is attached to the symbol output data as a value Serial Cmd K726 aperture overall edge determination decode contrast mini mum reflectance minimum edge contrast modulation defects decod ability quiet zone Default Disabled Options 0 Disabled 1 E...

Страница 261: ...ries User s Manual Z392 ISO IEC 15416 Symbol Quality Output Grading Report VAL4 Responds with a text report that summarized the grading of ISO IEC15416 This command will return the evaluation results in a format similar to the one shown below ...

Страница 262: ...bled 1 Enabled Definition Cell Contrast is calculated in accordance with the ISO 29158 specifica tion When enabled the Cell Contrast is attached to the symbol output data as a value Serial Cmd K727 overall cell contrast cell modulation fixed pattern damage axial non uniformity grid non uniformity unused ECC Default Disabled Options 0 Disabled 1 Enabled Definition Cell Modulation is calculated in a...

Страница 263: ...l out put data as a value Serial Cmd K727 overall cell contrast cell modulation fixed pattern damage axial non uniformity grid non uniformity unused ECC Default Disabled Options 0 Disabled 1 Enabled Definition Grid Non Uniformity is calculated in accordance with the ISO 29158 specification When enabled the Grid Non Uniformity is attached to the symbol out put data as a value Serial Cmd K727 overal...

Страница 264: ...430 series User s Manual Z392 8 29 Symbol Quality Grading Report VAL5 Responds with a text report that summarized the grading of ISO IEC29158 This command will return the evaluation results in a format similar to the one shown below ...

Страница 265: ...8 30 Auto Focus Multi Code Reader V430 series User s Manual Z392 ISO IEC 29158 Symbol Quality Output ...

Страница 266: ...tents This section explains the matchcode output functions and the master symbol database setup Matchcode by ESP 9 2 Matchcode Serial Commands 9 3 Overview of Matchcode 9 4 Matchcode Type 9 5 Sequence Step Interval 9 10 Match Replace 9 11 Mismatch Replace 9 12 New Master Pin 9 13 ...

Страница 267: ...s User s Manual Z392 Matchcode by ESP Matchcode by ESP To open nested options single click the To change a setting double click the setting and use your cursor to scroll through the options Click the Parameters button and then the Matchcode tab ...

Страница 268: ...tion match length wildcard character sequence on No Read sequence on mismatch Number of Master Symbols K224 number of master symbols New Master Pin K225 status Sequence Step Interval K228 sequence step interval Master Symbol Data K231 index master symbol data Match Replace K735 status match replacement string Mismatch Replace K736 status mismatch replacement string ...

Страница 269: ... Master Pin command and activate the discrete input to store the next symbol read as the master symbol Definition Matchcode allows the user to store master symbol data in the reader s memory compare that data against other symbol data and define how symbol data and or discrete signal output will be directed A master symbol database can be set up for up to 10 master symbols Note Matchcode will func...

Страница 270: ... on mismatch Default Disabled Options 0 Disabled 1 Enabled 2 Wild Card 3 Sequential Disabled Has no effect on operations Enabled Instructs the reader to compare symbols or portions of symbols with the master symbol Wild Card Allows the user to enter user defined wild card characters in the master symbol Sequential Instructs the reader to sequence after each match numeric only and compare symbols o...

Страница 271: ...tion determines the portions of symbols that will be matched by defining the first character in the symbol from left to right that will be compared with those of the master symbol when Matchcode Type is set to Enabled or Sequential Function For example if Match Start Position is set to 3 the first 2 characters read in the symbol will be ignored and only the 3rd and subsequent characters to the rig...

Страница 272: ...T123 This means any wild cards appended to the master symbol data will result in matches of symbols in variable lengths up to the master symbol lengths but not over However wild cards in the beginning or center of a symbol e g UR NT do not allow for variable symbol lengths Definition Wild Card Character allows a user to define a wild card character as part of the master symbol Serial Cmd K223 matc...

Страница 273: ...symbol on every match or No Read When disabled it does not sequence on a No Read Serial Cmd K223 matchcode type sequential matching match start position match length wild card character sequence on No Read sequence on mismatch Default Enabled Options 0 Disabled 1 Enabled Master Symbol Decoded Symbol Master Symbol after Decode 001 001 002 002 002 003 003 No Read 004 sequenced on No Read 004 004 005...

Страница 274: ...smatch may occur Definition When set to Enabled the master symbol sequences on every decode match or mismatch When set to Disabled the master symbol will not sequence whenever consecutive mismatches occur Serial Cmd K223 matchcode type sequential matching match start position match length wild card character sequence on No Read sequence on mismatch Default Disabled Options 0 Disabled 1 Enabled Mas...

Страница 275: ...han 1 Definition Sequencing in Matchcode operations can occur in steps from 1 to 32 768 Sequencing performs like a mechanical counter by displaying positive integers and a specific number of digits after roll overs For example 000 3 997 not 3 and 999 3 002 not 1002 Serial Cmd K228 sequence step interval Default 1 Options Any number from 1 to 32768 Master Symbol Decoded Symbol Master Symbol after D...

Страница 276: ...r a symbol matches a master symbol Definition Outputs a user defined data string whenever a match occurs and Matchcode is enabled Serial Cmd K735 status replacement string Default Disabled Options 0 Disabled 1 Enabled Definition User defined data string that when enabled replaces symbol data whenever a match occurs Serial Cmd K735 status replacement string Default MATCH Options An ASCII string up ...

Страница 277: ... symbol does not match a master symbol Definition Outputs a user defined data string whenever a mismatch occurs and Matchcode is enabled Serial Cmd K736 status replacement string Default Disabled Options 0 Disabled 1 Enabled Definition User defined data string that when enabled replaces symbol data whenever a mismatch occurs Serial Cmd K736 status replacement string Default MISMATCH Options An ASC...

Страница 278: ... series Input 1 pin 3 is Default and Input 2 pin 4 is New Master Serial Cmd K225 status Default Disabled Options 0 Disabled 1 Enabled Definition The new master status responds with the number of the next master position to be loaded where 0 represents idle or no master to be loaded Example If the user has the Number of Master Symbols set to 1 and then either sends a G or toggles an active New Mast...

Страница 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...

Страница 280: ...10 2 Camera and IP Setup Serial Commands 10 3 Video 10 4 Evaluation 10 5 Calibration 10 8 Window of Interest 10 9 Configuration Database 10 13 Dynamic Setup 10 14 Pixel Binning 10 15 Camera Settings 10 16 White Balance Settings QSXGA Color Only 10 17 Color Filter 10 18 Focus Setup 10 19 Illumination Brightness 10 21 Morphological Pre Processing 10 22 Morphological Operation and Operator Size 10 23...

Страница 281: ...anual Z392 Camera and IP Setup by ESP Camera and IP Setup by ESP Click the Setup button to bring up the Camera Setup menu To open nested options single click the To change a setting double click the setting and use your cursor to scroll through the options ...

Страница 282: ... distance distance units focus mode no read limit Illumination Brightness K536 brightness light source Camera Settings K541 exposure gain Pixel Binning K542 pixel binning status Color Filter K543 color filter White Balance K544 red gain green gain blue gain Morphological Pre Processing K550 status Morphological Operation K551 morphological operation operator size Set License K556 license file name...

Страница 283: ...at any time and to decode the symbol data Similar to the Capture and Decode function in the Configuration views Initiates the Test routine Allows the user to test the reader s read rate and decodes per second and also displays decoded symbol data in the field at the bottom of the screen Click Stop to end the Test routine Clicking this icon enables the focal distance slide control to the right of t...

Страница 284: ...led in Number of Captures under Capture Mode in the Camera Setup menu tree to the left of the tabs If you click Save the current image will be saved to the location of your choice Note An image can only be saved in the format in which it was uploaded to ESP JPEG images will be saved as jpg and bitmaps will be saved as bmp When you click the JPEG Image box notice that the Line Scan button is grayed...

Страница 285: ...adjust the scroll bars in order to bring the image into view 3 To generate a histogram click and drag your cursor diagonally across the symbol or a portion of the symbol The image will be surrounded by an area of interest box a dashed blue line with red anchor points that can be selected and moved by placing a cursor inside the box and can be resized by clicking and dragging the anchor points Usag...

Страница 286: ...llows you to move the line anywhere in the window You can also use your keyboard arrows to move the line incrementally in any direction As with the histogram the line scan compares light and dark pixels but in a spatial distribution On the Y axis of the graph below 0 is black and 255 is white the X axis represents the horizontal axis of the symbol as described by the line scan When you click anywh...

Страница 287: ...o control several complex simultaneous calibration operations and to follow the progress of those operations using cues such as progress bars real time representations of calibration values and other dynamic user feedback See the Calibration section for full documentation of this feature ESP s Calibration interface shown during a calibration routine ESP s Calibration interface shown after a calibr...

Страница 288: ... the desired symbol is located The programmable window of interest increases decode speed improves threshold and makes it easy to select specific symbols from among several in the field of view The user provides the upper left pixel location and the size of the window in rows and columns to define the Window of Interest Important Window of Interest will shrink the field of view and therefore could...

Страница 289: ...over the symbol that you want to isolate for reading Notice that the surrounding area goes black You can use the handles on the image area that you have just drawn to resize the region of interest You can also click on the center of the window of interest and move it 3 Test the new settings in Read Rate Mode Note To remove the window of interest click the Reset button or click anywhere in the WOI ...

Страница 290: ...Serial Cmd K516 row pointer column pointer row depth column width Default All models 0 Options V430 F000 50C QSXGA 0 to 1944 row depth V430 F000 12M SXGA 0 to 960 row depth V430 F M03M WVGA 0 to 480 row depth Definition Defines the column position of the upper left starting point of the image window Serial Cmd K516 row pointer column pointer row depth column width Default All models 0 Options V430...

Страница 291: ... this setting would still return 101 Definition Defines the size in rows of the image window Maximum value is defined as the maximum row size of the image sensor minus the Row Pointer value Serial Cmd K516 row pointer column pointer row depth column width Default V430 F000 50C QSXGA 1944 V430 F000 12M SXGA 960 V430 F M03M WVGA 480 Options V430 F000 50C QSXGA 3 to 1944 row pointer V430 F000 12M SXG...

Страница 292: ...iles It is a useful tool in applications that require several different reader configurations to be applied sequentially and it allows the user to perform far more complex operations than would be possible with only one set of configuration parameters See Configuration Database for full documentation of this feature Configuration Database view 5 Active Indexes Capture Settings highlighted ...

Страница 293: ... Setup Dynamic Setup is used to calculate image capture timing during a read cycle Without proper timing the reader will not be able to decode all symbols in a read cycle An external trigger is used to activate image captures so the user can make timing adjustments as capture events occur ...

Страница 294: ...480 will be scaled to 320 x 240 Definition In addition to windowing the image sensor smaller resolutions can be obtained by down sampling the entire captured image by using pixel binning Pixel binning can increase the signal to noise ratio and produce a more pleasing output image with reduced artifacts It will also improve low light performance It is important to note that enabling pixel binning d...

Страница 295: ... movement of the object becomes less of a factor but with the duration of light collection by the pixels reduced the image sensor gain will need to be increased to compensate Serial Cmd K541 exposure gain Default All versions 2 500 μs Options Any number between 50 100 000 Note The Exposure parameter is read only when the reader is in Continuous Read Auto Trigger Mode Usage Can be used to adjust th...

Страница 296: ...ge sensor and is a percentage value from 0 lowest gain to 100 highest gain The color channel parameters are used to avoid unrealistic colors so that objects that appear white to the human eye are rendered white in the final image The default value for this parameter is factory calibrated Blue Gain Sets the gain value for the blue color channel of the image sensor and is a percentage value from 0 l...

Страница 297: ...B image to provide a grayscale image for decoding similar to a luminance calculation Unlike a luminance calculation Green Interpolate provides an image 1 1 resolution to the input image This filter provides better omni directional symbol decode performance Like Horizontal 1D Symbols and unlike General Purpose a white balance is not necessary This filter is recommended for most decoding application...

Страница 298: ...nce distance units focus mode no read limit Default Millimeters Options 0 Millimeters 1 1 100 inch For example the following are valid configurations to set the Focal Distance to three distances Required Focal Distance Distance Units mm 0 Distance Units 1 100 in 1 2 inch or 50 mm K525 50 0 K525 200 1 3 inch or 76 mm K525 76 0 K525 300 1 6 inch or 152 mm K525 152 0 K525 600 1 Definition This field ...

Страница 299: ... Z392 Focus Setup No Read Limit Definition This is the number of no reads that are encountered consecutively in a Continuous Read mode to trigger an Autofocus pass Serial Cmd K525 focal distance distance units focus mode no read limit Default 5 Options 1 to 255 ...

Страница 300: ...rightness of the illumination LEDs Since the reader has control over the brightness of the illumination it can provide consistent brightness output between readers through a factory calibration operation Each of the brightness settings is calibrated to provide the same level of intensity for each reader Serial Cmd K536 brightness light source Default High Options 0 Off 1 Low 2 Medium 3 High 4 Cons...

Страница 301: ...ocessing Morphological Pre Processing allows you to select the method for processing images and to choose the operator size for that method Important This command must be set to Enabled for Morphological Operation to function Serial Cmd K550 morphological pre processing Default Disabled Options 0 Disabled 1 Enabled ...

Страница 302: ...dark cell size of a dark on light Data Matrix symbol Dilate Shrink Dark Dilate increases the light cell size of a symbol Useful for increasing the light cell size of a light on dark Data Matrix symbol Definition Morphological Operation allows the user to select the method for processing captured images Serial Cmd K551 0 morphological operation operator size Default Grow Dark Options 0 Grow Dark 1 ...

Страница 303: ...peration and Operator Size Open Connect Dark Open removes minor light defects of dark cells by performing a Dilate function followed by an Erode function Close Separate Dark Close removed minor dark defects of light cells by performing an Erode function followed by a Dilate function ...

Страница 304: ...n Operator Size determines the size of the area or pixel neighborhood measured in pixels in which the morphological operation is being performed Serial Cmd K551 0 morphological operation operator size Default Small Options 3 Small 3 pixels by 3 pixels 5 Medium 5 pixels by 5 pixels 7 Large 7 pixels by 7 pixels ...

Страница 305: ... Symbol is enabled the reader will make additional attempts to decode damaged Code 128 and Code 39 symbols It is effective on symbols with high noise and partial bar missing Enabling Damaged Symbol may significantly increase decode time Serial Cmd K519 damaged symbol status Default Disabled Options 0 Disabled 1 Enabled ...

Страница 306: ...near Security Level Definition Linear Security Level is intended to prevent misreads When it is set to a higher level it requires more scan lines to decode the same result making it more secure Serial Cmd K560 linear security level Default Aggressive Options 0 Aggressive 1 Normal 2 Secure ...

Страница 307: ...ention the file name should begin with the first three octets of the target device s MAC address followed by a short key descriptor An example filename is 17B2C3 X Mode lic License Key The License Key field is a 29 character string representing the license key The key is generated by a proprietary licensing tool and the format is a sequence of five five character dash separated fields An example k...

Страница 308: ...used to fine tune the reader s performance in your application Configuration Database Serial Commands 11 2 Number of Active Indexes 11 3 Configuration Database Status 11 4 Database Mode 11 10 Save Current Settings to Configuration Database 11 15 Load Current Settings from Configuration Database 11 16 Request Selected Index Settings 11 17 Request All Configuration Database Settings 11 17 ...

Страница 309: ...on Database Status K255 index exposure gain focal distance pixel binning row pointer column pointer row depth column width symbology morphology operator morphology size Save Current Settings to Database K255 index Load Current Settings from Database K255 index Request Selected Index Settings K255 index Request All Database Settings K255 Database Mode K256 switch mode frame count time image process...

Страница 310: ...that will be used automatically during the read cycle If Number of Active Indexes is set to 0 only the current reader settings will be used not database entry settings Serial Cmd K252 number of active indexes sort database Default 0 Disabled Options 0 to 10 Definition Sort Database moves the database entry that produced a successful decode to the first position in the list of database entries Seri...

Страница 311: ...depth column width symbology morphology operator morphology size Options 1 to 10 Serial Cmd K255 index exposure gain focal distance pixel binning row pointer column pointer row depth column width symbology morphology operator morphology size Default 2500 Options 50 to 100 000 Serial Cmd K255 index exposure gain focal distance pixel binning row pointer column pointer row depth column width symbolog...

Страница 312: ...ition The image dimension settings can be applied as a Window of Interest or a Region of Interest depending on the image dimension mode selected in the Database Mode command Serial Cmd K255 index exposure gain focal distance pixel binning row pointer column pointer row depth column width symbology morphology operator morphology size Default All models 0 Options V430 F000 50C QSXGA 0 to 1944 row de...

Страница 313: ...A 960 V430 F M03M WVGA 480 Options V430 F000 50C QSXGA 3 to 1944 row pointer V430 F000 12M SXGA 3 to 960 row pointer V430 F M03M WVGA 3 to 480 row pointer Definition The image dimension settings can be applied as a Window of Interest or a Region of Interest depending on the image dimension mode selected in the Database Mode command Serial Cmd K255 index exposure gain focal distance pixel binning r...

Страница 314: ...9 will be active for this database index Codabar Add 32 If enabled Codabar will be active for this database index Code 93 Add 64 If enabled Code 93 will be active for this database index Definition This field allows the user to configure the database to enable specific symbologies for selected database indexes Symbology specific parameters must be configured with the appropriate symbology command ...

Страница 315: ...4 command must be configured as follows K482 2 If the DataBar 14 status parameter in the K482 command is set to either Disabled or Enabled the reader will only read non stacked DataBar 14 symbols DataBar Limited Add 16384 If enabled DataBar Limited will be active for this database index DataBar Expanded Add 32768 If enabled DataBar Expanded will be active for this database index Important If the s...

Страница 316: ...ndex exposure gain focal distance pixel binning row pointer column pointer row depth column width symbology morphology operator morphology size Default Disabled Definition Specifies the morphology operator size to apply Small 3 x 3 Medium 5 x 5 and Large 7 x 7 Serial Cmd K255 index exposure gain focal distance pixel binning row pointer column pointer row depth column width symbology morphology ope...

Страница 317: ...ion Selects the event that causes the reader to load the next database entry to current active settings When Frame Count Time expires and Image Process Looping is enabled the next database entry with modifications to camera settings will be used Note The image capture event always occurs when the first database entry is used Note The Switch Mode setting has no effect on Rapid Capture Mode which al...

Страница 318: ...ive settings no new image is captured Note An exception to this is the first database index a new image is always captured when the first database index is used When a camera setting has been modified from one database setting to the next a new image is captured For example if all database entries contained the same camera setting values but had different IP and decode parameters an image frame wo...

Страница 319: ...determine the size of the image to be captured Definition Determines how the image dimension parameters will be implemented Serial Cmd K256 switch mode frame count time image process looping image dimensions Default 0 Options 0 Window of Interest 1 Region of Interest Camera settings Capture Index Exposure Gain Pixel Binning located in the left half of the highlighted area Image capture dimensions ...

Страница 320: ...mple DB1 and DB3 determine the size of the captured image WOI while DB2 has no impact The image WOI is not configurable It is automatically set up by the database according to the ROI settings Note Since the ROI parameters are not a camera setting a change in ROI parameters from one index to another does not indicate an image capture event This feature is intended to be used in conjunction with Im...

Страница 321: ...erest ROI by ESP When Image Dimensions is set to Region of Interest the database image dimension parameters are IP and decode settings and they determine the region or area of the captured image to be processed Morphology Operation Morphology Size and Symbol Type are Processing Settings values ...

Страница 322: ...saves the reader s current active configuration settings to database index 5 Save Current Settings to Configuration Database by ESP Definition Allows current active configuration settings to be saved to a selected database index Serial Cmd K255 index Click the Load Current to Index button to save the reader s current configuration parameters to the selected database index ...

Страница 323: ...and the database DataBar Expanded status is Enabled The current DataBar 14 status does not change if it is configured as Enabled Stacked and the database DataBar Expanded status is Enabled Data Matrix ECC level is determined by the current settings and not by database settings Therefore the database does not know which ECC level to enable and has no effect on current Data Matrix ECC settings Defin...

Страница 324: ...ration settings for database index 5 Request All Configuration Database Settings Example K255 This command phrase returns the configuration settings for all 10 database indexes Definition Returns configuration settings for the selected database index Serial Cmd K255 index Definition Returns configuration settings for all indexes in the Configuration Database Serial Cmd K255 ...

Страница 325: ...11 18 Auto Focus Multi Code Reader V430 series User s Manual Z392 Request All Configuration Database Settings ...

Страница 326: ... Multi Code Reader V430 series User s Manual Z392 12 1 12 Terminal Contents This section describes the Terminal window and macro functions in ESP Terminal 12 2 Find 12 3 Send 12 4 Macros 12 5 Terminal Menus 12 6 ...

Страница 327: ... The Terminal screen also displays symbol data or information from the reader You can also right click on the Terminal screen to bring up a menu of further options Click this button to display the Terminal view Click on desired Macro to run Click on macros arrow to Add Macro Remove Macro or Edit Macro Type text here to find matching text in the Terminal window Type serial commands here Macros list...

Страница 328: ...dow For example a series of symbols have been scanned into the Terminal view and you want to determine if a particular symbol whose data begins with ABC has been read 1 Type ABC into the Find box 2 Press Enter The first instance of ABC will be highlighted in the Terminal window 3 Click the Find button to the left of the text field to locate additional instances of ABC ...

Страница 329: ...30 series User s Manual Z392 Send Send The Send function allows you to enter serial commands and then send them to the reader 1 Type the command into the Send box 2 Press Enter 3 Click the Send button to the left of the text field to send ...

Страница 330: ... the reader at the same time that it is displayed Editing a Macro When you click the arrow next to any macro and select Edit the following appears You can edit an existing macro or type in the Macro Name text field and define it in the Macro Value text field Click OK Click on Next Row to see the next row of macros Click on the first arrow here to see Add Macro or Default Macros When macros are def...

Страница 331: ...er Change Background Color of Terminal window Non Printable Characters allows you to hide non printable characters or to show them in Standard or Enhanced format Default Settings returns all the above settings to default Keyboard Macros allows you to create new keyboard macro commands that can be sent from function keys F2 F4 F5 etc Capture Text lets you append data in real time to a text file of ...

Страница 332: ...are Serial utility commands are not prefaced with a K and a numeric code nor do they require an initialization command A and Z They can be entered from within any terminal program or from ESP s Terminal or Utilities windows Operational Commands 13 2 Read Rate 13 4 Counters 13 6 Device Control 13 8 Differences from Default 13 9 Master Database 13 10 Firmware 13 16 Default Reset Save 13 19 Reader St...

Страница 333: ...e Checksum b Request Boot Code Firmware Checksum s Request Current Parameter Settings Checksum Read Rate C Decodes Per Second Test Cp Decode Percent Test J Exit Read Rate Tests a1 Preface PDF417 Output with Data Attributes Device Control L1 Pulse Programmable Output 1 L2 Pulse Programmable Output 2 L3 Pulse Programmable Output 3 Read Cycle Enable Disable I End Current Read Cycle until H H Enable R...

Страница 334: ...icroscan Default Parameters Including Communication and Custom Unit Name Parameters and Save for Power On Master Database G Store Next Symbol Read to Database Index 1 Gn Store Next Symbol Read to Database Index n NEWM New Master Load Status Reader Status Reader Status Request Train Optimize TRAIN Initiate Train Operation UNTRAIN Initiate Untrain Operation TRAIN Train Status Request OPT Initiate Op...

Страница 335: ... click the Decodes sec radio button and then the Start button To see the percentage of decodes click the Percent radio button and then the Start button To end a Read Rate test click the Stop button the Start button becomes a Stop button during an active Read Rate test Read Rate information is displayed in the lower portion of the Utilities view Serial commands can also be sent to the reader from t...

Страница 336: ...mbol data if any The decode rate can vary dramatically due to the angle and location of the symbol in relation to the field of view This test is very useful in aligning and positioning the reader during setup Enter Percent Test Sending Cp instructs the reader to transmit the percentage of decodes and any decoded symbol data End Read Rate Test Sending J ends both the Percent test and the Decodes Se...

Страница 337: ...ve command Click the Request button to display the appropriate count or Clear to set the counter to zero Click the Utilities button and then the Counters tab to display the Counters view Trigger Good Read No Read and Mismatch counters can be requested and cleared simultaneously Request All and Clear All buttons or individually Request and Clear buttons to the left of each item ...

Страница 338: ...ood Read Counter Sending V displays the total number of good reads matching the master symbol or if Master Symbol is not enabled the number of good reads since the last reset This counter is always enabled but will only work as a match count when Master Symbol is enabled If Master Symbol is not enabled this counter records the number of good reads This count can be requested at any time Good Read ...

Страница 339: ...mbol or Output 3 status Disable Reader Sending I will turn the reader OFF end the current read cycle and will not allow the reader to enter another read cycle until turned ON This feature is useful during extended periods of time when no symbols are being decoded or the reader is being configured Disabling the reader will not affect any commands that have already been downloaded Enable Reader Send...

Страница 340: ...send the settings to the reader and save them or Send to Reader to send the settings without saving them Important To use Differences from Default connect to the reader and Receive Reader Settings via the Send Recv button on the toolbar Click the Utilities button and then the Differences tab to display the Differences from Default view Click this button for a list of ESP configuration settings tha...

Страница 341: ... deleted by serial or ESP commands 1 Click the Master Database tab 2 Enable Matchcode Type 3 Set the Master Symbol Database Size 4 Select the database index in which the master symbol will be entered 5 Do one of the following to enter master symbol data a Double click the index row to type data directly into the index b Click the Read Symbol into Selected Index to enter the next decoded symbol Cli...

Страница 342: ...o exceeds the size limitation The table below specifies the maximum number of characters available to each symbol according the number of master symbols defined from 1 to 10 Definition Number of Master Symbols allows you to select 1 to 10 master symbols for the master symbol database Serial Cmd K231 master symbol number master symbol data Note You must follow this command with a save command A or ...

Страница 343: ...the maximum allowed For example to enter data for master symbol 9 after making certain that master symbol database size is enabled for 9 or more symbols send K231 9 data Important The ASCII characters and can only be entered as hex values Caution If no data is entered the existing data will be deleted ESP 1 Open the Utilities menu 2 Set the number of master symbols you want to create in Master Sym...

Страница 344: ...mbol 5 data in brackets in the following format 5 If no master symbol data is available the output will be 5 Serial Cmd K231 master symbol number Caution Be sure to add the or you will delete the master symbol Note This command returns the number of master symbols if no number is included ESP 1 Click the Utilities button and the Master Database tab 2 Click the Receive Reader s Database button Defi...

Страница 345: ... symbol read to be entered as master symbol 5 ESP In the Master Database tab under the Output Format menu 1 Select the master symbol index number in which you want to store the symbol data 2 Click the Read Symbol into Selected Index button Caution If you ve selected an index which already has existing data that data will be copied over by new decoded data when you use this command Usage Informs th...

Страница 346: ...l 2 Click the Master Database tab and double click the symbol number you want to delete 3 Delete text and click OK Serial Cmd K231 master symbol number To delete a master symbol enter the database number and a comma but leave the data field empty For example to delete master symbol 5 send the following K231 5 The command is entered with a blank master symbol data field which tells the reader to de...

Страница 347: ...er 3 Before updating you should verify the current firmware 4 Click in the Firmware Update text box and select the file type you want to download This will open a file locator box 5 Navigate to the appropriate file open the file and click Start Caution Do not interrupt power or disconnect the host cable while download is in progress Be sure that each download is complete before moving on to the ne...

Страница 348: ...ction 3 Select the code type to see its part number displayed in the text field to the right of the Request Part No button Request Part Number by Serial Command When you send a request for all product part numbers the reader returns b BOOT_P N a APP_P N p PROFILE_P N When you send a a request for the application code part number the reader returns a APP_P N When you send b a request for the boot c...

Страница 349: ...type to see its checksum displayed in the text field to the right of the Request Checksum button Request Checksum by Serial Command When you send a request for all available firmware checksums the reader returns b BOOT_CHECKSUM a APP_CHECKSUM p PROFILE_CHECKSUM When you send a a request for the application code checksum the reader returns a APP_CHECKSUM When you send b a request for the boot code ...

Страница 350: ... a When you right click in a menu tree and select Default Current Menu Settings or Default All ESP Settings it is important to note that only ESP settings are defaulted To save these defaults to the reader itself you need to follow up with a Save to Reader Send and Save command Resets not saved for power on Reset A Save to Reader Send No Save Reset and Recall Microscan Defaults Ard No Reset and Re...

Страница 351: ...n then recall the previous customer saved settings with an Arc or Zrc command Microscan Default Parameters Microscan default parameters are contained in the firmware and cannot be changed Software Defaults Microscan default parameters can be recalled loaded into current settings with Ard command or recalled and saved for power on with the Zrd command Hardware Default If a software default and rese...

Страница 352: ...urrent configuration Sending this request will return the current settings of all commands starting with the lowest K command value and ending with the highest K command value K All Descriptor Status Request This request will return all current descriptors for every K command starting with the lowest K command value and ending with the highest K command value K All Range Status Request This reques...

Страница 353: ...t exceed the number of database slots for the specific command Knnn Single Descriptor Status Request This request returns the basic functional description of all fields in the requested K command Knnn Single Range Status Request This request will return the value range and storage type description of all fields in the requested K command Knnn Display Command Wildcard This request will return the i...

Страница 354: ... This command will cause the product to discard any information acquired during a Train operation The Untrained state can be saved for a power on condition using the Z command Train Status Format TRAIN Responds with Train Status This command will return the current status of the TRAIN operation Response TRAIN 0 Default not trained TRAIN 1 Train operation in process TRAIN 2 Symbol trained Train Per...

Страница 355: ...on acquired during a Optimize operation The Un Optimized state can be saved for a power on condition using the Z command Optimize Status Format OPT Responds with Optimize Status This command will return the current status of the OPT operation Response OPT 0 Default not optimized OPT 1 Optimize operation in process OPT 2 Symbol optimized Optimize Persistence The Optimize state and parameters persis...

Страница 356: ... path filename Image Library Request op 9 Manages files in a selected directory File Source Explanation Nothing All files in root directory All files in root directory saved All files in saved directory All files in all directories del Deletes all files in the root directory saved del Deletes all files in the saved directory del Deletes files in all directories ...

Страница 357: ...such as serial verification or counter requests the data will be routed to the host port Bar Code Configuration Mode can be exited by any reset A Z or J command The command to exit Bar Code Configuration Mode can be included as part of the Data Matrix symbol For example try encoding K200 4 K220 1 J into a Data Matrix symbol This configures the reader to enable Serial Trigger Mode to program a new ...

Страница 358: ...ut Format Contents This section explains how to control the formatting and filtering of decoded symbol data for output Output Format Serial Commands 14 2 Output Format Status 14 3 Format Assign 14 4 Format Insert 14 7 Output Filter Configuration 14 9 Number of Filters 14 14 ...

Страница 359: ... Extract K740 output index start location length Format Insert K741 output index length hex string Format Assign K742 symbol number status Format Status K743 output format status Output Filter Configuration K744 filter number symbology length wildcard placeholder data unused database index Output Format Count K745 number of filters ...

Страница 360: ...rmatting is enabled However Format Assign Format Insert and Format Extract must be properly set up as well Output Format Status by ESP Definition This is a global enable disable parameter In order to use formatting you must set up the format using the insert and extract commands and you must also assign a symbol to format using the Format Assign command Serial Cmd K743 output format status Default...

Страница 361: ...ons 1 to 10 1 Formatted output status for symbol 1 2 Formatted output status for symbol 2 10 Formatted output status for symbol 10 Definition Status refers to the user defined formatting of a selected symbol position in the read cycle result Note that there is also a global formatting enable command that must be set for the formatting to be applied Serial Cmd K742 symbol number status Default Disa...

Страница 362: ... extract or insert command to continue building the output string Continue this process until you are finished building the string Serial Cmd K740 output index start location length Options 1 to 100 Definition Defines the location within the symbol data where the character extraction will begin The first character extracted will also be the first character in the sequence displayed in user defined...

Страница 363: ...range is characters 2 4 The Sample Symbol example on the Symbol Parse dialog shows the selected character positions extracted and output as desired Simultaneously the data string from the selected symbol is displayed at the bottom left of the Parse Table followed by the user defined extracted output The Extract Range function corresponds to the Start Location and Length parameters in the Format Ex...

Страница 364: ... character sequences For example if you wish to insert a 10 character sequence in user defined output you would need three commands with consecutive index numbers where the first two character sequence lengths were 4 and the third was 2 Serial Cmd K741 output index length hex string Default 0 disabled end of format cell array Options 0 to 4 Definition Specifies a character string that represents A...

Страница 365: ...anual Z392 Format Insert Format Insert by ESP The Insert process is very similar to the Extract process except that Insert allows the user to enter characters using the Insert calculator shown above Notice that Extract and Insert share the same Parse Table ...

Страница 366: ...output will occur in the order the symbols are decoded Output Filter Configuration Rule 3 All qualified symbols will be sorted and output in the matching filter position If a symbol matches filter 3 it will be output as the third symbol If a filter does not have a matching qualified symbol a No Read message will be output in place of the symbol assuming the No Read message is enabled For example i...

Страница 367: ...ldcard placeholder data unused database index Options 1 to 10 Definition Specifies the symbology allowed to occupy this location in multisymbol output Note To filter or order a symbol the symbol must meet all the requirements of the selected filter index Serial Cmd K744 filter number symbology length wildcard placeholder data unused database index Default 0 any symbology Options 0 Any type 1 Inter...

Страница 368: ... used in the data output field when performing a data filter comparison The wildcard character represents the end of matching and allows for variable lengths of symbol output Serial Cmd K744 filter number symbology length wildcard placeholder data unused database index Default 2A hex Options Any ASCII input in the form of a pair of hex characters Example 2A 00 disabled Definition The placeholder c...

Страница 369: ... will match 1234A and 123BA but not 123 1234C or 1234ABCD Filter data 123 A This will match 1234AB and 123BAT but not 1234A or 123BATS Filter data 12 This will match 1234 123456 and 123ABC but not 12 or 123 Filter data 123 A This will match 1234A 123BA and 123BATS but not 1234 or 1234C Serial Cmd K744 filter number symbology length wildcard placeholder data unused database index Default 00 NUL Opt...

Страница 370: ...clicking on a row in the Ordered Output table brings up the Ordered Output Filter Settings dialog Use these settings to determine Symbology Type Length of the symbol a user defined Matching String ASCII Lookup Wildcard Character Placeholder Character and Database Number Click Apply to save the settings to the corresponding filter ...

Страница 371: ...rs 0 disables all output filters Any non zero numeral will enable filtering to be performed using the filter indexes covered by this value For example if the number of filters is 1 then only filter index 1 will be applied If the number of filters is 2 then only filter index 1 and filter index 2 will be applied etc Serial Cmd K745 number of filters Default 0 Options 0 to 10 ...

Страница 372: ...r V430 series User s Manual Z392 A 1 Appendices Contents Appendix A General Specifications A 2 Appendix B Serial Commands A 23 Appendix C Communications Protocol A 25 Appendix D ASCII Table A 26 Appendix E Glossary of Terms A 27 ...

Страница 373: ...d Four Red LEDs wave length 625 nm Outer LEDs Eight White LEDs Outer LEDs Eight Red LEDs wave length 617 nm Outer LEDs Eight Red LEDs wave length 617 nm Installation distance 3 Field of view 3 Pitch angle α 30 Skew angle β 30 Tilt angle γ 180 Image capture device Effective pixels 2592 H x 1944 V 1280 H x 960 V 752 H x 480 V Color Monochrome Color CMOS Monochrome CMOS Monochrome CMOS Shutter Method...

Страница 374: ... C with no icing or con densation Ambient humidity range Operating 5 to 95 RH Storage 5 to 85 RH with no condensa tion Ambient atmosphere No corrosive gases Vibration Resistance destruction 10 to 55 Hz double amplitude 0 35 mm X Y Z directions 10 cycles axis Shock resis tance destruction 150 m s2 3 times in each X Y Z directions Degree of protection IEC 60529 IP67 Weight Main body only Approx 68 g...

Страница 375: ...uto Focus QSXGA Wide View V430 F000W50C Auto Focus QSXGA Middle View V430 F000M50C Unit mm Auto Focus SXGA Wide View V430 F000W12M Fixed Focus WVGA Middle View Auto Focus SXGA Middle View V430 F000M12M Auto Focus SXGA Narrow View V430 F000N12M 50 37 210 265 51 Field of view Field of view 300 50 42 9 235 7 314 3 57 2 Field of view 300 50 27 4 148 8 198 4 36 5 Field of view 300 40 7 5 29 5 39 10 Fie...

Страница 376: ...m Read Ranges mm Typical 2D Ele ment Size mm Horizontal Vertical Inside Outside 50 35 5 25 46 5 54 5 0 13 102 66 49 94 110 0 13 300 184 143 227 373 0 38 Focal Distance mm Field of View mm Read Ranges mm Typical 2D Ele ment Size mm Horizontal Vertical Inside Outside 50 57 2 42 9 37 64 0 19 102 109 5 82 2 74 131 0 26 300 314 3 235 7 224 427 0 77 Focal Distance mm Field of View mm Read Ranges mm Typi...

Страница 377: ...m V430 F000N12M WD 40 mm Field of view 10 7 5 mm The minimum size is what could be read in ideal conditions Focal Distance mm Field of View mm Read Ranges mm Typical 2D Ele ment Size mm Horizontal Vertical Inside Outside 50 35 21 5 43 58 0 19 81 49 33 65 97 0 26 102 65 41 83 121 0 26 Model Minimum 2D Element Size mm V430 F000W50C 0 09 V430 F000M50C 0 09 V430 F000W12M 0 13 V430 F000M12M 0 09 V430 F...

Страница 378: ...Auto Focus Multi Code Reader V430 series User s Manual Z392 A 7 Appendices Dimensions Code Reader V430 F 2 M3 5DP 4 M3 5DP ...

Страница 379: ...d is provided through the cable shields and chassis of the camera If V430 F malfunctioned due to influence of the environment by shield cables grounded try any of them below Disconnect the chassis and the shield cable of the power supply from the earth POWER SUPPLY Ethernet Device RJ45 connector SHIELD Chassis ISOLATION ISOLATION NON ISOLATION RS232 422 485 Device RS232 422 485 SHIELD Ethernet SHI...

Страница 380: ...Ground Loops Ground loops signal degradation due to different ground potentials in communicating devices can be eliminated or minimized by ensuring that both the host imager and their power supplies are connected to a common earth ground Note If a malfunction occurred to your reader by noise mount a noise filter RSAL2001W manufactured by TDK Lambda Corp close to the reader s power supply terminals...

Страница 381: ...re that mounting bracket Earth is at the same potential as power source Earth Supply Return and Earth ground must be stable low impedance reference points 2 Terminal Power Supply must still provide an Earth connection to the imager Signal Ground can be used for communications and or discrete signal ground refer ence It must not be used as Power Ground or Earth Ground ...

Страница 382: ...Auto Focus Multi Code Reader V430 series User s Manual Z392 A 11 Appendices Connectors V430 series M12 Connectors M12 8 pin Socket Ethernet M12 12 pin Plug M12 12 pin Plug M12 8 pin Socket Ethernet ...

Страница 383: ... Numbers Description V430 WE 3M Cordset M12 8 Pin Plug to RJ45 Ethernet 3M V430 WELD 3M Cordset M12 8 Pin Plug to RJ45 Ethernet Right Angle Down 3M V430 WELU 3M Cordset M12 8 Pin Plug to RJ45 Ethernet Right Angle Up 3M V430 WE 5M Cordset M12 8 Pin Plug to RJ45 Ethernet 5M Item Model V430 WE 3M V430 WELD 3M V430 WELU 3M V430 WE 5M Cable length 3m 3m 3m 5m Minimum bending radius 73 7mm Weight 225g 2...

Страница 384: ...dset M12 12 Pin Socket to Flying Leads Right Angle Down 3M V430 W8LU 3M Cordset M12 12 Pin Socket to Flying Leads Right Angle Up 3M V430 W8 5M Cordset M12 12 Pin Socket to Flying Leads 5M V430 W2 3M Cordset M12 12 Pin Socket to DB9 Socket with M12 12 Pin Plug Item Model V430 W8 3M V430 W8LD 3M V430 W8 LU 3M V430 W8 5M V430 W2 3M Cable length 3m 3m 3m 5m 3m Wire gauge Power line AWG24 Other lines A...

Страница 385: ...Brown 2 24V Power Blue 7 0V Ground Red 8 COM_IN Input Common Red Blue 12 COM_OUT Output Common White 1 TRIG Trigger Black 9 HOST_RxD RS 232 Host RxD Purple 10 HOST_TxD RS 232 Host TxD Gray 5 OUTPUT1 Output 1 Gray Pink 11 OUTPUT2 Output 2 Pink 6 OUTPUT3 Output 3 Green 3 DEFAULT Default Yellow 4 NEW MASTER New Master None Shield 63 3000 cable label Code Reader attachment connector M12 12 pin socket ...

Страница 386: ... Socket with M12 12 Pin Plug V430 W2 3M Unit mm Please connect V430 W8 to I O connector M12 12 pin plug and connect to a power supply SHIELD 21 5 35 3 3000 63 cable label Code Reader attachment connector M12 12 pin socket 5000 63 cable label Code Reader attachment connector M12 12 pin socket SHIELD 48 5 48 3 44 5 2700 100 300 63 RS232C D Sub 9 pin socket cable label Code Reader attachment connecto...

Страница 387: ...ternal device Turn OFF the power supply before connecting or disconnecting a Cable Peripheral devices may be damaged if the cable is connected or disconnected with the power ON Use a slotted screwdriver when fixing screws of the D Sub connector are hard to loosen Pin No Signal name 1 2 HOST_RxD 3 HOST_TxD 4 5 0V 6 7 8 9 Pin No Signal name 1 TRIG 2 24V 3 DEFAULT 4 NEW MASTER 5 OUTPUT1 6 OUTPUT3 7 0...

Страница 388: ... LEDs Polarizer V430 AF2 Polarizer reduces glare from specular objects Polarizer passes light from diffuse objects Specular Vertical Reflections are filtered out Only Horizontal component of Diffuse Reflections make it to the camera Accessories Gasket 1 Phillips Head Screws 4 Accessories Gasket 1 Phillips Head Screws 4 With Diffuser Without Diffuser Accessories Gasket 1 Phillips Head Screws 4 With...

Страница 389: ...er 2 Remove the four screws from the front window of the reader 3 Remove the front window and gasket 4 Install the gasket onto the reader Ensure that the gasket is properly seated in place and is covering all sealing sur faces 5 Install the window V430 AF0 or window accessory V430 AF1 AF2 onto the reader 6 Secure the window in place using the screws provided Do not over tighten the screws 1 0 in l...

Страница 390: ...Auto Focus Multi Code Reader V430 series User s Manual Z392 A 19 Appendices 48 0 44 0 4 9 VIEW A A A 2 5 A ø3 4 45 0 41 5 3 5 ø3 4 THRU ø6 4 X 90 8 0 22 2 24 0 42 3 Mirror ...

Страница 391: ...ations Mounting Bracket sold separately L Bracket It s possible to adjust the angle V430 AM0 Unit mm Material SUS304 Thickness 2 5mm Accessories Phillips HeadScrews M3 6 2 Washer 2 R19 0 R8 0 R13 0 2X ø2 4 2X 17 7 21 2 60 0 30 0 50 0 58 8 80 0 65 0 2 5 60 0 30 0 35 0 ø6 6 R20 0 R3 3 ...

Страница 392: ... Manual Z392 A 21 Appendices Installation method In case of side installation In case of base installation Phillips head screw M3x6P 0 5mm Mounting bracket Washer Mounting holes Mounting holes Washer Phillips head screw M3x6P 0 5mm Mounting bracket ...

Страница 393: ...it mm Note Mounting the V430 F requires the use of the front set of mounting holes closest to the window Material Aluminum alloy Thickness 6 4mm Accessories Cap Screws M3 6 2 6 4 4 4 1 4 20 THRU 3 2 ø6 5 2X ø3 4 2X 44 5 22 2 3 2 6 2 6 2 12 7 ø2 4 THRU ø4 4 2 2 2X 25 4 Mounting holes Cap screw M3x6 Mounting bracket ...

Страница 394: ...follow the command Z initializes the memory and saves for power on A initializes the memory but does not save for power on For example to enable UPC and save the change for power on send K473 1 Z To change Baud Rate and reset without saving changes for power on send K100 3 A Serial Configuration Command Conventions All command fields except the last must be followed by a comma without a space NULL...

Страница 395: ...The status of a specific serial command can be requested by entering the command followed by a question mark For example send K142 to request the status of Postamble Entering Control Characters in Serial Commands To enter control characters within a serial command hold down the Ctrl key while typing the desired character Example To enter a carriage return and line feed M J enter K141 1 CNTL m CNTL...

Страница 396: ...Command Table Protocol Command Mnemonic displayed on menu Control Characters Entered in menu or serial command Hex Value Effect of Command RES D 04 Reset REQ E 05 Request EOT D 04 Reset STX B 02 Start of Text ETX C 03 End of Text ACK F 06 Acknowledge NAK U 15 Negative Acknowledge XON Q 11 Begin Transmission XOFF S 13 Stop Transmission ...

Страница 397: ... j 11 0B VT K 43 2B 75 4B K 107 6B k 12 0C FF L 44 2C 76 4C L 108 6C l 13 0D CR M 45 2D 77 4D M 109 6D m 14 0E SO N 46 2E 78 4E N 110 6E n 15 0F SI O 47 2F 79 4F O 111 6F o 16 10 DLE P 48 30 0 80 50 P 112 70 p 17 11 DC1 Q 49 31 1 81 51 Q 113 71 q 18 12 DC2 R 50 32 2 82 52 R 114 72 r 19 13 DC3 S 51 33 3 83 53 S 115 73 s 20 14 DC4 T 52 34 4 84 54 T 116 74 t 21 15 NAK U 53 35 5 85 55 U 117 75 u 22 16...

Страница 398: ...The hardware organization of a vision system designed for high speed image analysis Aspect Ratio The ratio between the height and width of a sensor or display Found by dividing the vertical number of pixels height by the horizontal number of pixels width leaving it in fractional format Automatic Gain Control AGC Adjustment to signal strength that seeks to maintain a constant level regardless of th...

Страница 399: ...d specular glints from profiled highly reflective surfaces Digital to Analog Converter DAC A VLSI circuit used to convert digitally processed images to analog for display on a monitor Digital Imaging Conversion of an image into pixels by means of an Analog to Digital Converter where the level of each pixel can be stored digitally Digital Signal Processor DSP A VLSI chip designed for ultra high spe...

Страница 400: ...mory Front End System The object illumination optics and imager blocks of a vision system Includes all components useful to acquire a good image for subsequent processing Full Duplex A communications system in which signals can travel simultaneously between devices Gain The amount of energy applied to pixel gray scale values prior to output expressed in dB optimal signal strength Good Read A decod...

Страница 401: ...ion picture noise is any unwanted electrical signal that interferes with the image being read and transferred by the imager Normally Closed A discrete output state that is only active when open Normally Open A discrete output state that is only active when closed Object Plane An imaginary plane in the field of view focused by an imager s optical system at the corresponding image plane on the senso...

Страница 402: ... called a region of interest for image processing operations Saturation The degree to which a color is free of white One of the three properties of color perception along with hue and value Scattering Redirection of light reflecting off a surface or through an object Skew Rotation of a linear or 2D symbol around an axis parallel to the symbol height on the substrate Substrate The surface upon whic...

Страница 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...

Страница 404: ... 60169 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron com Kyoto JAPAN OMRON ASIA PACIFIC PTE LTD No 438A Alexandra Road 05 05 08 Lobby 2 Alexandra Technopark Singapore 119967 Tel 65 6835 3011 Fax 65 6835 2711 OMRON CHINA CO LTD Room 2211 Bank of China Towe...

Отзывы: