Trigger Mode and Filter Duration
External Level
Important:
Level
and
Edge
apply to the active logic state (
Active Open
or
Active Closed
)
that exists while the object is in a read cycle, between the rising edge and the falling edge.
Rising edge
is the trigger signal associated with the appearance of an object.
Falling edge
is
the trigger signal associated with the subsequent disappearance of the object. This applies
both to
External Level
and
External Edge
.
External Edge
Usage:
This mode is effective in an application where the speeds of the conveying
apparatus are variable and the time the reader spends reading each object
is not predictable. It also allows the user to determine if a No-Read has
occurred.
Definition:
External Level
allows the read cycle (active state) to begin when a trigger
(change of state) from an external sensing device is received. The read
cycle persists until the object moves out of the sensor range and the active
trigger state changes again.
Serial Cmd:
<
K200,
2
>
Usage:
This mode is highly recommended in any application where conveying
speed is constant, or if spacing, object size, or read cycle timeouts are
consistent.
Definition:
External Edge
, as with Level, allows the read cycle (active state) to begin
when a trigger (change of state) from an external sensing device is
received. However, the passing of an object out of sensor range does not
end the read cycle. The read cycle ends with a good read output, or,
depending on the
End of Read Cycle
setting, a timeout or new trigger
occurs.
Serial Cmd:
<
K200,
3
>
Initiate Read Cycle:
Object #1, moving in front of the
detector beam, causes a
change in the trigger state,
which initiates the read cycle.
End Read Cycle:
The same object, moving out of
the detector beam, causes
another change in the trigger
state, which ends the read cycle.
Initiate Read Cycle:
Object # 1, moving in front of the
detector beam, causes a change in
the trigger state, which initiates the
read cycle.
Initiate Second Read Cycle:
Object # 2, moving in front of the
detector beam, causes another
change in the trigger state. This sig-
nal initiates a new read cycle and
ends the previous read cycle unless
Timeout
is enabled and a good read
or timeout has not occured.
Содержание V430-F-series
Страница 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Страница 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Страница 97: ...4 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 Additional Notes about Calibration ...
Страница 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Страница 265: ...8 30 Auto Focus Multi Code Reader V430 series User s Manual Z392 ISO IEC 29158 Symbol Quality Output ...
Страница 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Страница 325: ...11 18 Auto Focus Multi Code Reader V430 series User s Manual Z392 Request All Configuration Database Settings ...
Страница 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...