5-18
Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
Capture Mode
Number of Captures
Note:
The range of maximum number of captures is dynamic. This range is dependent
on the maximum image size in the system. A full-size image (1280 x 1024) reduces the
maximum number of images to
6
. The smaller the image size, the greater the maximum
number of captures. Once the image size is reduced to small enough dimensions, the
maximum number of captures will be capped at
64
.
If a user enters a maximum capture value greater than that allowed, the value will be
limited to the number of system images. This command also affects the number of
stored images allowed in the system. If the maximum number of captures is selected,
the number of stored images allowed will be
0
.
Rapid Capture Mode
Usage:
Number of Captures
is used to specify the number of captures to be processed
in
Rapid Capture Mode
.
Definition:
Sets the total number of captures that are processed during a read cycle in
Rapid Capture Mode
. This feature is used in conjunction with
Capture Timing
parameters to specify the capture sequence of a rapid capture read cycle.
Serial Cmd:
<
K241,
capture mode,
number of captures
,rapid capture mode,number of
continuous captures,images per read cycle limit,read cycle history
>
Default:
1
Options:
1 to 255
Definition:
In
Rapid Capture Mode
, one or multiple captures (as many as 32) can be
taken at an interval specified by the time-between-captures parameter. In
this mode, the only limiting time factor is integration and transfer timing.
Serial Cmd:
<
K241,
capture mode,number of captures,
rapid capture mode
,number of
continuous captures,images per read cycle limit,read cycle history
>
Default:
Timed Capture
Options:
0 = Timed Capture
1 = Triggered Capture
Содержание V430-F-series
Страница 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Страница 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Страница 97: ...4 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 Additional Notes about Calibration ...
Страница 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Страница 265: ...8 30 Auto Focus Multi Code Reader V430 series User s Manual Z392 ISO IEC 29158 Symbol Quality Output ...
Страница 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Страница 325: ...11 18 Auto Focus Multi Code Reader V430 series User s Manual Z392 Request All Configuration Database Settings ...
Страница 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...