Precautions for Safe Use
13
Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
• Make sure to use the product with the power supply voltage specified by this manual.
• Do not connect AC power source to Sensor Controller. If connects AC power source, it might be a
cause of the failure.
• Use the wire of a suitable size (AWG 16 to 12) according to the current consumption.
• Use a DC power supply with safety measures against high-voltage spikes (safety extra low-voltage
circuits on the secondary side).
• Keep the power supply wires as short as possible.
• Do the following confirmations again before turning on the power supply.
• Is the voltage and polarity of the power supply correct?
• Is not the load of the output signal short-circuited?
• Is the load current of the output signal appropriate?
• Is not the mistake found in wiring?
• The recommended power supply is the S8VS-
24 (manufactured by OMRON) or
S8VK-G-
24 (manufactured by OMRON).
• Check wiring again before turning on the V430 reader.
• Use only the cables (V430-W
: sold separately) designed specifically for the product. Use of other
products may result in malfunction or damage of the product.
• Always turn OFF the power of the reader and peripheral devices before connecting or disconnecting
a cable. Connecting the cable with power supplied may result in damage of the reader or peripheral
devices.
• Do not apply torsion stress to the cable. It may damage the cable.
• Secure the minimum bending radius of the cable. Otherwise the cable may be damaged.
• Do not attempt to dismantle, repair, or modify the product.
• Should you notice any abnormalities, immediately stop use, turn OFF the power supply, and contact
your OMRON representative.
• While the power is ON or immediately after the power is turned OFF, the case are still hot. Do not
touch the case.
• The reader must be used with the special mounting bracket (V430-AM0 or V430-AM1: sold sepa-
rately), or the reader may generate heat.
• When disposing of the product, treat it as an industrial waste.
• Do not drop the product nor apply excessive vibration or shock to the product. Doing so may cause
malfunction or burning.
• When controlling stages and robots using the read results (axis movement output based on calibra-
tion and alignment measurement), always take fail-safe measures within the stage and robot sys-
tems, such as checking whether the data obtained from the read results is within the range of
movement of the stages and robots.
Power Supply and Wiring
Ground
Other
Содержание V430-F-series
Страница 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Страница 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Страница 97: ...4 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 Additional Notes about Calibration ...
Страница 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Страница 265: ...8 30 Auto Focus Multi Code Reader V430 series User s Manual Z392 ISO IEC 29158 Symbol Quality Output ...
Страница 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Страница 325: ...11 18 Auto Focus Multi Code Reader V430 series User s Manual Z392 Request All Configuration Database Settings ...
Страница 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...