Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
7-9
I/O Parameters
No-Read Message
No-Read Message Mode
Disabled
Only symbol data is output after a read cycle.
Enabled
When the reader is in a triggered mode, a No-Read message will be appended for each
failed read attempt.
No-Read Message
Note: No-Read Message
will only be transmitted if
Symbol Data Output
is set to
Match
,
Mismatch
, or
Good Read
.
No-Read Message
can be set to any ASCII character.
Usage:
Used in applications where the host needs serial verification that a symbol
has not been read and especially useful in new print verification.
Definition:
When enabled, and if no symbol has been decoded before timeout or the
end of the read cycle, the No-Read message will be transmitted to the host.
Serial Cmd:
<
K714,
No-Read message status
,No-Read message
>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled
Definition:
Any combination of ASCII characters can be defined as the No-Read
message.
Serial Cmd:
<
K714,
No-Read message status,
No-Read message
>
Default:
NOREAD
Options:
A string of up to 64 characters.
Содержание V430-F-series
Страница 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Страница 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Страница 97: ...4 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 Additional Notes about Calibration ...
Страница 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Страница 265: ...8 30 Auto Focus Multi Code Reader V430 series User s Manual Z392 ISO IEC 29158 Symbol Quality Output ...
Страница 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Страница 325: ...11 18 Auto Focus Multi Code Reader V430 series User s Manual Z392 Request All Configuration Database Settings ...
Страница 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...