![background image](http://html1.mh-extra.com/html/omron/v430-f-series/v430-f-series_user-manual_741958235.webp)
7-70
Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
Image Push to Host Detailed Setup
RAM Drive Size in MB
Save Image Until
Action at Image Storage Limit
Definition:
This defines the maximum RAM Drive size on the system. It is also limited to
the memory available on the system and affects the max. rapid image count in
<K241>
since the onboard memory may be taken up by the RAM Drive.
Images may not be saved if the RAM Drive is not large enough to store all the
images in the current read cycle and if
Image Storage Location
is set to
FTP
with
Image Save Mode
set to
Speed
. If Image Storage Location is set to FTP
with Image Save Mode set to
Accuracy
, all images in the read cycle will be
transferred to the FTP host but the read cycle may be delayed.
Serial Cmd:
<
K764,
image storage location,FTP host info,transfer optimization,
RAM
drive size in MB
,save image until,action at image storage limit
>
Default:
20
Options:
1 to 50
Definition:
This defines how long the image will be stored in the system when the
Image
Storage
Location
is
RAM
.
If set to
New Read Cycle
, the saved image will be erased upon entering the
next read cycle.
If set to
System Reset
, the saved image will be erased upon the next system
reset.
Serial Cmd:
<
K764,
image storage location,FTP host info,transfer optimization,RAM
drive size in MB,
save image until
,action at image storage limit
>
Default:
New Read Cycle
Options:
1 = New Read Cycle
2 = System Reset
Definition:
This defines what to do when
Action at Storage Full
is reached and when
images are saved on
RAM
. When this setting is set to
Erase Oldest First
, the
oldest images in the current read cycle will be erased.
Serial Cmd:
<
K764,
image storage location,FTP host info,transfer optimization,RAM
drive size in MB,save image until,
action at image storage limit
>
Default:
Stop
Options:
0 = Stop
1 = Erase Oldest First
Содержание V430-F-series
Страница 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Страница 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Страница 97: ...4 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 Additional Notes about Calibration ...
Страница 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Страница 265: ...8 30 Auto Focus Multi Code Reader V430 series User s Manual Z392 ISO IEC 29158 Symbol Quality Output ...
Страница 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Страница 325: ...11 18 Auto Focus Multi Code Reader V430 series User s Manual Z392 Request All Configuration Database Settings ...
Страница 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...