9-4
Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
Overview of Matchcode
Overview of Matchcode
Steps for Entering and Using Master Symbols
1. Set
Triggering Mode
to
External
or
Serial
.
2. Choose the method of symbol comparison that fits your application.
3. Define the output you want to achieve with your matchcode setup:
a. Symbol data output
b. Discrete output
4. Select the number of master symbols you want to create.
5. Decide which of 4 ways you want to enter your master symbol(s):
a. Use
ESP
to type master symbol data directly.
b. Send a serial command with symbol data in the form of
<M231,
master symbol#,
data
>
.
c. Send a
<G>
(
Read Next Symbol as Master Symbol
) command.
d. Enable the
New Master Pin
command and activate the discrete input to store the
next symbol read as the master symbol.
Definition:
Matchcode
allows the user to store master symbol data in the reader’s
memory, compare that data against other symbol data, and define how
symbol data and/or discrete signal output will be directed.
A master symbol database can be set up for up to 10 master symbols.
Note: Matchcode
will function with multiple symbols; however, if
Matchcode
Type
is set to
Sequential
or if
Triggering Mode
is set to
Continuous Read 1
Output
, the reader will behave as if
Number of Symbols
were set to
1
,
regardless of the user-defined configuration.
Usage:
Matchcode is used in applications to sort, route, or verify data based on
matching the specific symbol in a variety of ways as defined in this section.
For example, a manufacturer might sort a product based on dates that
are embedded in the symbol.
Содержание V430-F-series
Страница 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Страница 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Страница 97: ...4 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 Additional Notes about Calibration ...
Страница 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Страница 265: ...8 30 Auto Focus Multi Code Reader V430 series User s Manual Z392 ISO IEC 29158 Symbol Quality Output ...
Страница 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Страница 325: ...11 18 Auto Focus Multi Code Reader V430 series User s Manual Z392 Request All Configuration Database Settings ...
Страница 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...