background image

Magellan

TM

 800i

On-Counter Presentation Omnidirectional 

Bar Code   Reader

Product Reference Guide

Содержание Magellan 800i

Страница 1: ...MagellanTM 800i On Counter Presentation Omnidirectional Bar CodeReader Product Reference Guide...

Страница 2: ...be downloadable from the Datalogic website www datalogic com or provided on appropriate media If you visit our website and would like to make comments or suggestions about this or other Datalogic pub...

Страница 3: ...te 15 Good Read Beep Control 16 Good Read Beep Frequency 16 Good Read Beep Length 17 Good Read Beep Volume 18 Scanning Features 19 Wake Up Intensity 19 Image Capture 21 How to Capture an Image 21 Imag...

Страница 4: ...YMBOLOGIES 59 UPC A 60 Disable Enable UPC A 60 Check Digit Transmission 60 Expand UPC A to EAN 13 61 Number System Digit NSD Transmission 61 UPC A Minimum Reads 62 UPC A In store Minimum Reads 62 UPC...

Страница 5: ...5 Code 39 Length 1 Length 2 Programming Instructions 86 Quiet Zones 86 Code 39 Stitching 87 Minimum Reads 87 Code 32 Italian Pharmacode 88 Disable Enable Code 32 Italian Pharmacode 88 Start Stop Chara...

Страница 6: ...k Digit Transmit 109 Length Control 110 Standard 2 of 5 Length 1 Length 2 Programming Instructions 110 Standard 2 of 5 Stitching 111 Minimum Reads 111 Code 11 112 Disable Enable Code 11 112 Check Char...

Страница 7: ...ffix 134 Label ID 135 Length Control 136 Length 1 Length 2 Programming Instructions 136 Appendix A PRODUCT SPECIFICATIONS 137 Optical and Read Performance Parameters 137 Scanner Dimensions 138 Physica...

Страница 8: ...vi Magellan 800i Scanner Appendix G SAMPLE SYMBOLS 155 1D Symbol Samples 155 2D Sample Symbols 156 Composite Sample Symbols 157 NOTES...

Страница 9: ...information see the Quick Reference Guide QRG Copies of other publications for this product are downloadable free of charge from the website listed on the back cover of this manual On leaving the fac...

Страница 10: ...serial port via the RS 232 cable as shown in Figure 1 If the terminal will not support POT Power Off the Terminal to supply scan ner power use the approved power supply AC Adapter Plug the AC Adapter...

Страница 11: ...e scanner to be placed in Programming Mode prior to scanning them Scan a START END bar code once to enterProgramming Mode Once the scanner is in Programming Mode you can scan a number of parameter set...

Страница 12: ...scanner is disabled due to receiving a disble command from the POS terminal Diagnostics Varies see Error Codes on page 5 for more information The LED can provide diagnostic feedback if the scanner dis...

Страница 13: ...ed its automatic Selftest and has entered FRU Field Replaceable Unit isolation mode If the scanner is reset or the trigger is pulled the sequence will be repeated The following table describes the LED...

Страница 14: ...6 Magellan 800i Scanner NOTES...

Страница 15: ...s This Double Read Timeout feature sets a time limit that determines how much time must pass before reading the same linear label again e g two identical items in succession START END PROGRAMMING BAR...

Страница 16: ...le Read Timeout for Linear Labels 8 Magellan 800i Scanner Double Read Timeout for Linear Labels cont 0 5 Second 004D32 CR 004D3C CR 0 6 Second DEFAULT 0 7 Second 004D46 CR 004D50 CR 0 8 Second 0 9 Sec...

Страница 17: ...mber of labels stored within the Double Read Time out setting This setting applies to Linear and 2D labels NOTE Double Read Queue Seven DEFAULT 03C900 CR 03C980 CR Double Read Queue One Setting this f...

Страница 18: ...eout feature specifies the minimum allowable time between consecutive good reads of the same PDF 417 Micro PDF 417 Data Matrix QR Code Maxicode Aztec or Composite label 03DF02 CR 20 mSec 40 mSec 03DF0...

Страница 19: ...ifies the amount of time with no bar code reads before the scanner enters sleep mode 03AF00 CR Disable Sleep Mode 15 Seconds 03AF01 CR 03AF02 CR 30 Seconds 1 Minute 03AF04 CR 03AF08 CR 2 Minutes 3 Min...

Страница 20: ...ng Mode Sleep Mode 12 Magellan 800i Scanner Sleep Mode cont 7 Minutes 03AF1C CR 03AF20 CR 8 Minutes 9 Minutes 03AF24 CR 03AF28 CR 10 Minutes 12 Minutes 03AF30 CR 03AF3C CR 15 Minutes 30 Minutes 03AF78...

Страница 21: ...e scanner has finished all its power up tests and is now ready for operation Disable 020700 CR 020701 CR Enable DEFAULT ERI Active State High This setting specifies the active state polarity of the Ex...

Страница 22: ...en milliseconds 10ms or 0 01 sec onds To configure this feature scan the Enter Exit Programming Mode bar code above to place the unit in Program ming Mode then the Set ERI Timeout followed by the two...

Страница 23: ...ive which uses CTS is only valid for RS 232 interfaces If set to this mode in other interfaces Indicate after decode mode will be assumed This setting will only work if CTS Scan control is enabled e G...

Страница 24: ...e scanner s ability to beep upon a successful decode of a bar code Disable 006700 CR 006701 CR Enable DEFAULT Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low medium or...

Страница 25: ...nce Guide 17 Good Read Beep Length Specifies the duration of a good read beep 001603 CR 30msec 40msec 001604 CR 001605 CR 50msec DEFAULT 60msec 001606 CR 001608 CR 80msec 100msec 00160A CR 00160C CR 1...

Страница 26: ...e LED and Beeper Indicators 18 Magellan 800i Scanner Good Read Beep Volume Selects the beeper volume loudness upon a good read beep There are three selectable volume levels Low 001900 CR 001901 CR Med...

Страница 27: ...icates the percentage of ambient light change which will trigger the scanner to wake up from Sleep Mode Lower settings provide greater sensi tivity The selectable range for this setting is 5 to 80 5 0...

Страница 28: ...Enter Exit Programming Mode Scanning Features 20 Magellan 800i Scanner Wake Up Intensity cont 50 60 70 80 03B832 CR 03B83C CR 03B846 CR 03B850 CR...

Страница 29: ...e to the Host by Host Command Image Capture by Scanning a Special label To initiate an Image Capture scan the IMAGE CAPTURE label below IMAGE CAPTURE Upon scanning this label the scanner s beeper will...

Страница 30: ...imum compression at a loss of quality Follow these steps to program this feature 1 Scan the START bar code 2 Scan the Set Image Compression bar code 3 Turn to Alphanumeric Pad and scan the two digits...

Страница 31: ...urable range is 00 0x0A by increments of 01 4 Scan the END bar code 03EB CR Set Image Brightness DEFAULT SETTING FOR THIS FEATURE 00 Image Contrast This feature sets the image contrast value Follow th...

Страница 32: ...ne display This mode is set as follows Disabled No cell phone mode Auto Will automatically go to cell phone mode Manual Will go to cell phone mode on receiving a command from the host See Appendix F H...

Страница 33: ...going into cell phone mode more often than the user would like the scanner can be set to low sensitivity by scanning the low sensitivity programming labels on the following page If the scanner does n...

Страница 34: ...041F3D CR Enter Exit Programming Mode Cell Phone Mode 26 Magellan 800i Scanner Cell Phone Mode Sensitivity cont Cell Phone Mode Sensitivity High Sensitivity SCAN ALL THREE BARCODES 042003 CR 0421C0 CR...

Страница 35: ...d in Select the desired interface type from the table then reference the page number given for the customizable features section associated with each interface RS 232 USB NOTE The correct interface ca...

Страница 36: ...Magellan 800i Scanner Interface Selection 000105 CR RS 232 Standard RS 232 Wincor Nixdorf 000112 CR 000145 CR USB OEM USB Keyboard 000135 CR 000147 CR USB COM USB TEC 00010D CR NOTE Interface specifi...

Страница 37: ...s Specifies the number of host transmission s that may be buffered By buffering data from a bar code the scanner can continue to read a new bar code while the old one is being transmitted to the host...

Страница 38: ...ce Features 30 Magellan 800i Scanner RS 232 Interface Features 001D04 CR 1200 Baud 2400 Baud 001D03 CR 001D02 CR 4800 Baud 9600 Baud DEFAULT 001D01 CR 001D00 CR 19200 Baud 38400 Baud 001D06 CR 001D07...

Страница 39: ...duct Reference Guide 31 RS 232 Interface Features cont 7 Data Bits 8 Data Bits DEFAULT 1 Stop Bit DEFAULT 2 Stop Bits Parity None DEFAULT Parity Even Parity Odd 009B00 CR 009B01 CR 002200 CR 002201 CR...

Страница 40: ...to read and transmit data While the CTS line is inactive the scanner remains in a host disabled state following a successful label transmission the CTS signal must transition to inactive and then to a...

Страница 41: ...tted If the transmission speed is too high the system may not be able to receive all characters You may need to adjust the delay to make the system work properly 009C00 CR Inter Char Delay No Delay DE...

Страница 42: ...FF characters 002100 CR Disable Software Flow Control DEFAULT Enable Software Flow Control 002101 CR Beep on ASCII BEL Enables disables ability of scanner to beep sound a good read tone on receiv ing...

Страница 43: ...on File Enables the scanner to cause beep to be sounded on receiving not on file NOF command 045100 CR Beep on Not On File Disable Beep on Not On File Low Volume DEFAULT 045101 CR 045102 CR Beep on N...

Страница 44: ...ctions for this option are Disable Enable for label transmission the scanner expects an ACK NAK response from the host when a label is sent Enable for host command acknowledge the scanner will respond...

Страница 45: ...f these char acters 8 bit data is not recognized when the Number of Data Bits 7 ASCII charac ters or any hex value from 0 to FF NAK Character NOTE Sets the NAK character from the set of ASCII characte...

Страница 46: ...by the two digits zero padded from the Alphanumeric table in Appendix C Alphanumeric Pad representing your desired value Exit programming mode by again scanning the Enter Exit Programming Mode bar cod...

Страница 47: ...rs Choices are 00 Ignore errors detected recommended setting 01 Process error as valid ACK character risk of lost label data 02 Process error as valid NAK character risk of duplicate label data 032300...

Страница 48: ...Options are Table Top Scanner Handheld Scanner 050D00 CR Configure as Table Top Scanner DEFAULT Configure as Handheld Scanner 050D01 CR USB Keyboard As a USB keyboard interface the scanner supports m...

Страница 49: ...de Interface Features 41 Magellan 800i Scanner USB Keyboard cont Denmark 030203 CR 030204 CR France Germany 030205 CR 030206 CR Italy Norway 030207 CR 030208 CR Portugal Spain 030209 CR 03020A CR Swed...

Страница 50: ...CR Enter Exit Programming Mode Product Reference Guide 42 USB Keyboard cont Japan 106 Key Hungary 03020D CR 03020E CR Czech Republic Slovakia 03020F CR 030210 CR Romania Croatia 030211 CR 030212 CR P...

Страница 51: ...se SHIFT LOCK MODE send character data in shifted case This only applies to Wedge G For other interface this setting results in a CAPS LOCK Off function ality CAPS LOCK COMPENSATION MODE Preserves the...

Страница 52: ...nsmitted Choices are Disable Control Characters Enable transmission of control characters to host Send characters between 00H and 1FH according to a special function key mapping table This is used to...

Страница 53: ...scan the Enter Exit Programming Mode bar code above to place the unit in Programming Mode then the Set Intercharacter Delay followed by the two digits zero padded from the Alphanumeric table in Appen...

Страница 54: ...46 Magellan 800i Scanner NOTES...

Страница 55: ...d be sent with all symbol ogies or only with specific symbologies Figure 1 shows the available elements you can add to a message string Figure 1 Breakdown of a Message String Prefix Suffix AIM ID Labe...

Страница 56: ...from the set of ASCII characters or any hex value from 00 to 7F To configure this feature scan the Enter Exit Programming Mode bar code above to place the unit in Programming Mode then the Set Prefix...

Страница 57: ...by A code character see the table below followed by A modifier character the modifier character is symbol dependent Figure 2 AIM ID Prefix Suffix Label ID Label ID Bar Code Data AIM ID 03A900 CR Disa...

Страница 58: ...l ID Position After bar code Data Set UPC A Label ID Character s 0024 CR DEFAULT SETTING FOR THIS FEATURE A 41 hex 002D CR DEFAULT SETTING FOR THIS FEATURE A 41 hex Set UPC A w P2 Addon Label ID Chara...

Страница 59: ...n Label ID Character s Set EAN 8 Label ID Character s DEFAULT SETTING FOR THIS FEATURE FF 4646 hex DEFAULT SETTING FOR THIS FEATURE FF 4646 hex Set EAN 8 w P2 Addon Label ID Character s Set EAN 8 w P5...

Страница 60: ...T SETTING FOR THIS FEATURE F 46 hex Set EAN 13 w C128 Addon Label ID Character s Set ISBN Label ID Character s DEFAULT SETTING FOR THIS FEATURE I 49 hex DEFAULT SETTING FOR THIS FEATURE G 47 hex Set G...

Страница 61: ...1 Expanded Label ID Character s Set Code GS1 DataBar Limited Label ID Character s DEFAULT SETTING FOR THIS FEATURE RL 524C0000 hex DEFAULT SETTING FOR THIS FEATURE 2A hex Set Code 39 Label ID Characte...

Страница 62: ...Plessey Label ID Character s DEFAULT SETTING FOR THIS FEATURE 40 hex DEFAULT SETTING FOR THIS FEATURE s 73 hex Set Std 2 of 5 Label ID Character s Set PDF 417 Label ID Character s DEFAULT SETTING FOR...

Страница 63: ...abel type DEFAULT SETTING FOR THIS FEATURE mP 6D500000 hex Set Micro PDF 417 Label ID Character s Set QR Code Label ID Character s DEFAULT SETTING FOR THIS FEATURE QR 51520000 hex DEFAULT SETTING FOR...

Страница 64: ...DEFAULT Convert to Upper Case 033101 CR 033102 CR Convert to Lower Case Case conversion affects ONLY scanned bar code data and does not affect Label ID Prefix Suffix or other appended data Label ID co...

Страница 65: ...character conver sion BG25TB82 The A characters were converted to the B character and the 1 characters were converted to the numeral 2 character Nothing is done with the last two char acter pairs sinc...

Страница 66: ...Enter Exit Programming Mode Character Conversion 58 Magellan 800i Scanner NOTES...

Страница 67: ...armac ode UPC E Code 128 EAN 13 Interleaved 2 of 5 EAN 8 JAN 8 Codabar GS1 DataBar Omnidirectional Code 93 GS1 DataBar Expanded Expanded Stacked MSI Plessey GS1 DataBar Limited Standard 2 of 5 Code 39...

Страница 68: ...A When disabled the scanner will not read UPC A bar codes 02D000 CR Disable UPC A Enable UPC A DEFAULT 02D001 CR Check Digit Transmission Enable this option to transmit the check digit along with UPC...

Страница 69: ...also changes the symbology ID to match those required for EAN 13 004300 CR Don t Expand to EAN 13 DEFAULT Expand to EAN 13 004301 CR Number System Digit NSD Transmission This feature enables disables...

Страница 70: ...ood read 006101 CR Minimum 1 Read DEFAULT Minimum 2 Reads 006102 CR 006103 CR Minimum 3 Reads Minimum 4 Reads 006104 CR UPC A In store Minimum Reads This feature specifies the minimum number of consec...

Страница 71: ...logy Disable Enable UPC E When disabled the scanner will not read UPC E bar codes 02D100 CR Disable UPC E Enable UPC E DEFAULT 02D101 CR Check Digit Transmission Enable this option to transmit the che...

Страница 72: ...24801 CR Expand to UPC E to UPC A Enables disables expansion of UPC E labels to UPC A Selecting this feature also changes the symbology ID to match those required for UPC A 004100 CR Don t Expand UPC...

Страница 73: ...006202 CR 006203 CR Minimum 3 Reads Minimum 4 Reads 006204 CR GTIN The following options apply to the GTIN label data format Expand UPC EAN to GTIN Enables conversion of UPC E UPC A EAN8 and EAN13 lab...

Страница 74: ...02D300 CR Disable EAN 13 Enable EAN 13 DEFAULT 02D301 CR Check Digit Transmission Enable this option to transmit the check digit along with EAN 13 bar code data 00B900 CR Don t Send Check Digit Send C...

Страница 75: ...These codes are used for books and maga zines Labels with ISBN codes start with 978 Example bar code data 9789572222720 Output 9572222724 Minimum Reads This feature specifies the minimum number of con...

Страница 76: ...e EAN 8 Enable EAN 8 DEFAULT 02D201 CR Check Digit Transmission Enable this option to transmit the check Digit along with EAN 8 JAN 8 bar code data 00B800 CR Don t Send Check Digit Send Check Digit DE...

Страница 77: ...Minimum Reads This feature specifies the minimum number of consecutive times an EAN 8 label must be decoded before it is accepted as good read 006501 CR Minimum 1 Read DEFAULT Minimum 2 Reads 006502...

Страница 78: ...nner to decode EAN two label pairs 004400 CR Disable EAN Two Label Enable EAN Two Label 004401 CR EAN Two Label Combined Transmission Enables disables the transmitting of an EAN two label pair as one...

Страница 79: ...Enable 4 digit price wt check digit calculation Enable 5 digit price wt check digit calculation Enable European 4 digit price weight check digit calculation Enable European 5 digit price weight check...

Страница 80: ...add on portion of a UPC EAN bar code but still read the main portion of the bar code 2 Digits The scanner will optionally read 2 digit add ons with the UPC EAN label 5 Digits The scanner will optiona...

Страница 81: ...dd Ons cont Enable Optional 5 Digit Add ons 051101 CR 051200 CR Disable Optional Code 128 Add ons DEFAULT Enable Optional Code 128 Add ons 051201 CR NOTE If a UPC EAN base label and a P2 addon are bot...

Страница 82: ...Scanner 5 Digit Addons Minimum Reads This setting configures the minimum number of times a 5 digit addon must decode before it is marked valid 007D01 CR Minimum 1 Read DEFAULT Minimum 2 Reads 007D02 C...

Страница 83: ...Disable Enable GS1 DataBar Omnidirectional When this feature is disabled the scanner will not read GS1 DataBar Omnidirec tional bar codes 04D000 CR Disable GS1 DataBar Omnidirectional DEFAULT Enable G...

Страница 84: ...er Minimum Reads This feature specifies the minimum number of consecutive times an GS1 DataBar Omnidirectional label must be decoded before it is accepted as good read 04D201 CR Minimum 1 Read DEFAULT...

Страница 85: ...1 is activated Disable Enable GS1 DataBar Expanded When this feature is disabled the scanner will not read GS1 DataBar Expanded bar codes 04D100 CR Disable GS1 DataBar Expanded DEFAULT Enable GS1 Data...

Страница 86: ...the scan ner will decode a bar code if the label length falls in the range of the configu rable lengths 1 and 2 04BD00 CR Variable Length Decoding DEFAULT Fixed Length Decoding 04BD01 CR GS1 DataBar E...

Страница 87: ...Reads This feature specifies the minimum number of consecutive times an GS1 DataBar Expanded label must be decoded before it is accepted as good read 04D301 CR Minimum 1 Read DEFAULT Minimum 2 Reads...

Страница 88: ...on filtering Enable UPC A Coupon Decoding UPCA EAN13 labels including coupon labels will decode but GS1 Expanded coupon labels will not GS1 Expanded labels that are not coupon labels will decode Enabl...

Страница 89: ...imited When this feature is disabled the scanner will not read GS1 DataBar Limited bar codes 035400 CR Disable GS1 DataBar Limited DEFAULT Enable GS1 DataBar Limited 035401 CR GS1 128 Emulation When e...

Страница 90: ...er Minimum Reads This feature specifies the minimum number of consecutive times an GS1 DataBar Limited label must be decoded before it is accepted as good read 035501 CR Minimum 1 Read DEFAULT Minimum...

Страница 91: ...codes 008E00 CR Disable Code 39 Enable Code 39 DEFAULT 008E01 CR Check Character Calculation When enabled the scanner will calculate the check character of the labels Turn this option on only when a c...

Страница 92: ...check character with scanned bar code data 008A00 CR Disable Check Char Transmission Enable Check Char Transmission DEFAULT 008A01 CR Start Stop Characters Enables disables transmission of Code 39 st...

Страница 93: ...F01 CR Length Control Fixed Length Decoding When fixed length decoding is enabled the scanner will decode a bar code if the label length matches one of the configurable fixed lengths Variable Length D...

Страница 94: ...ATURE 02 Set Length 1 Set Length 2 04B3 CR DEFAULT SETTING FOR THIS FEATURE 50 For Code 39 bar codes all check data and full ASCII shift characters are included in the length calculations Start Stop c...

Страница 95: ...bled by the scanner s software and the data will be decoded if all bar code proofing requirements are met 00D100 CR Disable Code 39 Stitching Enable Code 39 Stitching DEFAULT 00D101 CR Minimum Reads T...

Страница 96: ...to read Pharmacode 39 labels Disable Enable Code 32 Italian Pharmacode When this feature is disabled the scanner will not read Code 32 Italian Pharma code bar codes 00EE00 CR Disable Code 32 Italian P...

Страница 97: ...scanned bar code data 00EF00 CR Disable Check Char Transmission DEFAULT Enable Check Char Transmission 00EF01 CR Code 128 The following options apply to the Code 128 symbology Disable Enable Code 128...

Страница 98: ...ssion of Code128 function characters 1 2 3 and 4 Function codes are transmitted as follows FNC1 80 hex FNC2 81 hex FNC3 82 hex FNC4 83 hex NOTE 02C700 CR Don t Transmit Function Characters DEFAULT Tra...

Страница 99: ...can ner will decode a bar code if the label length falls in the range of the configu rable lengths 1 and 2 04B700 CR Variable Length Decoding DEFAULT Fixed Length Decoding 04B701 CR Code 128 Length 1...

Страница 100: ...control shall be applied to the label 069600 CR Disable DEFAULT Enable 069601 CR Code 128 Stitching Enables disables stitching for Code 128 labels When parts of a Code 128 bar code are presented to t...

Страница 101: ...Minimum Reads This feature specifies the minimum number of consecutive times a Code 128 label must be decoded before it is accepted as good read 006F01 CR Minimum 1 Read DEFAULT Minimum 2 Reads 006F02...

Страница 102: ...re is disabled the scanner will not read Interleaved 2 of 5 bar codes 009000 CR Disable Interleaved 2 of 5 DEFAULT Enable Interleaved 2 of 5 009001 CR Check Digit Calculation When enabled the scanner...

Страница 103: ...Digit Calculation DEFAULT 008B01 CR Length Control Fixed Length Decoding When fixed length decoding is enabled the scanner will decode a bar code if the label length matches one of the configurable f...

Страница 104: ...FOR THIS FEATURE 06 Set Length 1 Set Length 2 0057 CR DEFAULT SETTING FOR THIS FEATURE 50 Interleaved 2 of 5 Stitching Enables disables stitching for Interleaved 2 of 5 labels When parts of an Inter l...

Страница 105: ...ecoded before it is accepted as good read 006D01 CR Minimum 1 Read DEFAULT Minimum 2 Reads 006D02 CR 006D03 CR Minimum 3 Reads Minimum 4 Reads 006D04 CR Codabar The following options apply to the Coda...

Страница 106: ...label are treated as data characters 007100 CR Disable Check Char Verification DEFAULT Enable Check Char Verification 007101 CR Check Character Transmit Enable this option to transmit the check chara...

Страница 107: ...decode a bar code if the label length falls in the range of the configu rable minimum and maximum length 023300 CR Variable Length Decoding DEFAULT Fixed Length Decoding 023301 CR Codabar Length 1 Len...

Страница 108: ...odabar bar codes 068D00 CR Don t require Quiet Zones DEFAULT Require Quiet Zones 068D01 CR Start Stop Character Type Codabar has four pairs of Start Stop patterns Select one pair to match your applica...

Страница 109: ...start and stop characters match 023200 CR Disable Start Stop Char Match DEFAULT Enable Start Stop Char Match 023201 CR Codabar Stitching Enables disables stitching for Codabar labels When parts of a C...

Страница 110: ...er Minimum Reads This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as a good read 006C01 CR Minimum 1 Read DEFAULT Minimum 2 Reads 00...

Страница 111: ...ode 93 009101 CR Length Control Fixed Length Decoding When fixed length decoding is enabled the scanner will decode a bar code if the label length matches one of the configurable fixed lengths Variabl...

Страница 112: ...OR THIS FEATURE 50 For Code 93 bar codes only the data characters are included in the length calculations Code 93 Stitching Enables disables stitching for Code 93 bar codes When parts of a Code 93 lab...

Страница 113: ...accepted as a good read 006E01 CR Minimum 1 Read DEFAULT Minimum 2 Reads 006E02 CR 006E03 CR Minimum 3 Reads Minimum 4 Reads 006E04 CR MSI Plessey The following options apply to the MSI Plessey symbo...

Страница 114: ...CR Check Digit Transmit When this option is enabled the scanner will transmit one digit or two digit check digits depending upon the setting for check digit verification Applies when the feature Check...

Страница 115: ...l decode a bar code if the label length falls in the range of the configu rable minimum and maximum length 020000 CR Variable Length Decoding DEFAULT Fixed Length Decoding 020001 CR MSI Plessey Length...

Страница 116: ...ftware and the data will be decoded if all bar code proofing requirements are met NOTE 050000 CR Disable MSI Plessey Stitching DEFAULT Enable MSI Plessey Stitching 050001 CR Only functions when Fixed...

Страница 117: ...FAULT Enable Std 2 of 5 049401 CR Check Digit Verification When enabled the scanner will verify the check digit of the labels 049600 CR Disable Check Digit Verification DEFAULT Enable Check Digit Veri...

Страница 118: ...will decode a bar code if the label length falls in the range of the configu rable minimum and maximum length 049700 CR Variable Length Decoding DEFAULT Fixed Length Decoding 049701 CR Standard 2 of 5...

Страница 119: ...oftware and the data will be decoded if all bar code proofing requirements are met NOTE 059200 CR Disable Std 2 of 5 Stitching DEFAULT Enable Std 2 of 5 Stitching 059201 CR Only functions when Fixed L...

Страница 120: ...Code 11 DEFAULT Enable EAN 8 034201 CR Check Character Transmission Enables disables transmission of Code 11 check characters 034100 CR Don t Send Check Digit DEFAULT Send Check Digit 034101 CR Numbe...

Страница 121: ...the label length falls in the range of the configu rable minimum and maximum length 035900 CR Variable Length Decoding DEFAULT Fixed Length Decoding 035901 CR Code 11 Length 1 Length 2 Programming Ins...

Страница 122: ...ner Minimum Reads This feature specifies the minimum number of consecutive times a Code 11 label must be decoded before it is accepted as good read 034301 CR Minimum 1 Read DEFAULT Minimum 2 Reads 034...

Страница 123: ...the 2D symbologies bar code types listed below Avail able options for each 2D symbology are included in this chapter NOTE The features in this section are available ONLY for models with 2D features ac...

Страница 124: ...he START bar code 2 Scan the Fixed Length Decoding bar code 3 Scan the END bar code 4 Set Length 1 to the first fixed length by following the Length 1 Length 2 Programming Instructions below 5 Set Len...

Страница 125: ...n the four digits zero padded repre senting the length Scan the END bar code Variable Length Decoding DEFAULT Fixed Length Decoding 05A300 CR 05A301 CR NOTE For PDF 417 bar codes only the data charact...

Страница 126: ...um length Configuring Fixed Length Decoding 1 Scan the START bar code 2 Scan the Fixed Length Decoding bar code 3 Scan the END bar code 4 Set Length 1 to the first fixed length by following the Length...

Страница 127: ...r Set Length 2 bar code 3 Turn to Alphanumeric Pad and scan the three digits zero padded repre senting the length Scan the END bar code Variable Length Decoding DEFAULT Fixed Length Decoding 035B00 CR...

Страница 128: ...fixed length decoding is enabled the scanner will decode a bar code if the label length matches one of the configurable fixed lengths Variable Length Decoding When variable length decoding is enabled...

Страница 129: ...there is only one fixed length by following the Datamatrix Length 1 Length 2 Programming Instructions below Configuring Variable Length Decoding 1 Scan the START bar code 2 Scan the Variable Length D...

Страница 130: ...ded repre senting the length Scan the END bar code QR Code Disable Enable QR Code When disabled the scanner will not read QR Code labels NOTE For Datamatrix bar codes only the data characters are incl...

Страница 131: ...3 Scan the END bar code 4 Set Length 1 to the first fixed length by following the Length 1 Length 2 Programming Instructions below 5 Set Length 2 to the second fixed length or to 0000 if there is onl...

Страница 132: ...Code Disable Enable Micro QR Code When disabled the scanner will not read Micro QR Code labels NOTE For QR Code labels only the data characters are included in the length calculations Any value set hi...

Страница 133: ...bar code 2 Scan the Fixed Length Decoding bar code 3 Scan the END bar code 4 Set Length 1 to the first fixed length by following the Length 1 Length 2 Programming Instructions below 5 Set Length 2 to...

Страница 134: ...ad and scan the three digits zero padded repre senting the length Scan the END bar code Variable Length Decoding DEFAULT Fixed Length Decoding 03D200 CR 03D201 CR NOTE For Maxicode labels only the dat...

Страница 135: ...RT bar code 2 Scan the Fixed Length Decoding bar code 3 Scan the END bar code 4 Set Length 1 to the first fixed length by following the Length 1 Length 2 Programming Instructions below 5 Set Length 2...

Страница 136: ...and scan the four digits zero padded repre senting the length Scan the END bar code Variable Length Decoding DEFAULT Fixed Length Decoding 043200 CR 043201 CR NOTE For Aztec labels only the data char...

Страница 137: ...he state of the linkage flag Disable Enable GS1 DataBar Expanded 2D Component When enabled if a GS1 DataBar Expanded label is decoded which has the 2D linkage flag set the 2D component must also be de...

Страница 138: ...is decoded which has the 2D link age flag set the 2D component must also be decoded or the base label will be discarded When disabled only the GS1 DataBar Limited base label will be decoded and trans...

Страница 139: ...MING BAR CODES 03C600 CR Pharmacy Patterns Disable DEFAULT Pharmacy Patterns Enable 03C601 CR NOTE Pharmacy patterns are VSL 1D patterns that are almost exclusively in the fence orientation This loses...

Страница 140: ...ls the method of reading inverse labels white label on black back ground NOTE 040C00 CR 2D Read Mode Reads only normal labels DEFAULT 2D Read Mode Reads both normal and inverse labels 040C01 CR 040C02...

Страница 141: ...Reference Guide 133 Chapter 8 References This section contains explanations and examples of selected bar code features See the programming sections for the actual bar code labels used to configure the...

Страница 142: ...dd a dollar sign as a prefix 2 Scan the START bar code 3 Scan the SET PREFIX bar code 4 Reference the ASCII Character Set on page 159 on the inside back cover of this manual to find the hex value assi...

Страница 143: ...e a Label ID 1 Scan the START bar code 2 Select Label ID position as either BEFORE or AFTER by scanning the appro priate bar code 3 Scan a bar code to select the symbology for which you wish to config...

Страница 144: ...one fixed length by following the Length 1 Length 2 Programming Instructions below Configuring Variable Length Decoding 1 Scan the START END bar code 2 Scan the Variable Length Decoding bar code for t...

Страница 145: ...eters Parameter Specification Scan Volume 60 cubic inches Scan Pattern 140 Scan Linesa a These stats decline in Pharmacy Mode Scan Rate 1456 scan lines seconda Minimum Resolution 5 mil Depth of Field...

Страница 146: ...138 Magellan 800i Scanner Scanner Dimensions 151mm 98 4mm 109 1mm 48 7mm 71 3mm 76mm 35 4mm...

Страница 147: ...Operating label read 350mA 400 mA Environmental Parameters Parameter Specification Mechanical Shock Multi 1 2m drops Contaminants Water and Dust IP52 Temperature Ranges Operating 32 F to 104 F 0 C to...

Страница 148: ...140 Magellan 800i Scanner NOTES...

Страница 149: ...Product Reference Guide 141 Appendix B Cable Pinouts Standard Cable Pinouts Primary Interface Cables RS 232 Pin 1 10 Position RJ Scanner End 1 2 CTS 3 4 RTS 5 RXD 6 TXD 7 8 VCC IN 5V ONLY 9 GND 10...

Страница 150: ...Keyboard Pin 1 10 Position RJ Scanner End USB COM USB TEC External Read Indicator ERI NOTE This feature is available only through use of a special cable 1 D 2 3 D 4 5 6 7 8 VBUS_VIN 9 GND 10 1 2 3 4 5...

Страница 151: ...Product Reference Guide 143 Appendix C Alphanumeric Pad...

Страница 152: ...144 Magellan 800i Scanner A B C D E F NOTE For numeric entry sequences the scan ner will announce the number of digits remaining to be entered after each label read...

Страница 153: ...Product Reference Guide 145 Alphanumeric Pad 1 2 3 0 9 8 7 6 5 4...

Страница 154: ...146 Magellan 800i Scanner NOTES...

Страница 155: ...each symbology type Code Type Read Enable Checksum Verification Enable Checksum Transmission Enable Label ID UPC A A UPC E E EAN 13 F EAN 8 FF GS1 DataBar Omnidirectional R4 GS1 Expanded RX Code 39 Ph...

Страница 156: ...e QR Maxicode MC Aztec Az GS1 DataBar Omnidirectional 2D Com posite R4 GS1 DataBar Expanded 2D Composite RX GS1 DataBar Limited 2D Composite RL Code Type Read Enable Checksum Verification Enable Check...

Страница 157: ...Nixdorf Parameter Default Setting Interface Type RS 232 WN Number of Host Transmit Buffers One Buffer RS 232 Parity Odd RS 232 Hardware Control CTS Flow Control UCC EAN 128 Label ID P Code 39 Label ID...

Страница 158: ...150 Magellan 800i Scanner NOTES...

Страница 159: ...09 HT TAB right 00h 2Bh 0A LF RIGHT arrow inner keypad 00h 4Fh 0B VT TAB left 02h 2Bh 0C FF Enter right keypad 00h 58h 0D CR CR 00h 28h 0E SO INSERT inner keypad 00h 49h 0F SI PAGE UP inner keypad 00h...

Страница 160: ...152 Magellan 800i Scanner NOTES...

Страница 161: ...n FileIndication F 0x46 Illumination disabled scanner emits 3 beeps Must send the E command to re enable scanner Beep Good Read Tone B 0x42 Beeps if Good Read Beep is enabled Force Good Read Tone SOH...

Страница 162: ...st Command Preamble Charac ter P 0x50 0x04 Byte Count Fixed Value 0x04 p Image Capture Command Charac ter p 0x70 S Size 640x480 only S 0x53 B Brightness B or 0 min 9 max 0x42 or 0x30 0x39 Where B Scan...

Страница 163: ...t Reference Guide 155 Appendix G Sample Symbols 1D Symbol Samples UPC A 1234567890 Interleaved 2 of 5 Code 128 9 780330 290951 EAN 13 BC321 Code 39 A13579B Codabar 123456 9 Code 93 Code 128 0 12345678...

Страница 164: ...156 Magellan 800i Scanner 2D Sample Symbols 0100123456789050 GS1 DataBar Expanded 01 00123456789012 GS1 DataBar Omnidirectional Standard 2 of 5 01 16543210987654 GS1 DataBar Limited...

Страница 165: ...mposite Sample Symbols Product Reference Guide 157 Composite Sample Symbols A12B3C BV17453 1314H17LL PDF 417 Micro PDF 417 Datamatrix QR Code 35900G9 Maxicode 111TUVCCIUL7 1 Aztec This is an Aztec Cod...

Страница 166: ...158 Magellan 800i Scanner GS1 DataBar Limited Composite GS1 DataBar Truncated Composite...

Страница 167: ...SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SP 0 1 2 3 4 5 6 7 8 9 20 21 22 23 24 25...

Страница 168: ...atalogic S p A and its Group companies All rights reserved Protected to the fullest extent under U S and international laws Copying or altering of this document is prohibited without express written c...

Отзывы: